Analysis of the By-Pass Resistance of an Active Crowbar for Doubly-Fed Induction Generator Based Wind Turbines under Grid Faults

被引:0
|
作者
Zhang, Wei [1 ]
Zhou, Peng [1 ]
He, Yikang [1 ]
机构
[1] Zhejiang Univ, Coll Elect Engn, Hangzhou, Zhejiang, Peoples R China
来源
ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8 | 2008年
关键词
Crowbar; by-pass resistance; doubly fed induction generator; wind turbine; grid voltage dip;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The doubly-fed induction generator (DFIG) based wind turbines of today are often equipped with a crowbar, which can be used to limit the inrush rotor current and protect the ac excitation converter from damage via a set of resistors that am connected to the rotor windings of the DFIG. When the rotor current becomes too high due to the severe grid voltage dips on the transmission line, the crowbar is activated and the rotor side converter is disconnected from the rotor windings at the same time, which makes the DFIG behave as a squirrel cage induction generator with increased rotor resistance. This paper analyzes the influence of the crowbar resistors on the electrical behavior of the DFIG during the grid voltage dips. Approximate expression of the fault stator and rotor currents are deduced from mathematical analysis and verified by simulation. Different crowbar by-pass resistances and their impacts on the maximal fault currents and electromagnetic torque am examined by simulations with different parameter sets of the DFIG. Based on the simulation results, the appropriate crowbar by-pass resistance can be effectively predicted.
引用
收藏
页码:2316 / 2321
页数:6
相关论文
共 50 条
  • [31] Inertia Modeling of Brushless Doubly-fed Induction Generator and Stability Analysis of Wind Power Grid
    Lu, Min
    Li, Hui
    Zhao, Mi
    PROCEEDINGS OF THE 2017 INTERNATIONAL CONFERENCE ON ELECTRONIC INDUSTRY AND AUTOMATION (EIA 2017), 2017, 145 : 24 - 27
  • [32] Passivity Based Control of Doubly-Fed Induction Generators in Wind Turbines
    Lopez-Garcia, I.
    Jimenez-Mondragon, V. M.
    Campero-Littlewood, E.
    Espinosa-Perez, G. R.
    2010 IEEE ELECTRONICS, ROBOTICS AND AUTOMOTIVE MECHANICS CONFERENCE (CERMA 2010), 2010, : 607 - 612
  • [33] HYBRID FUZZY SLIDING MODE CONTROL OF A DOUBLY-FED INDUCTION GENERATOR IN WIND TURBINES
    Kerboua, Abdelfettah
    Abid, Mohamed
    REVUE ROUMAINE DES SCIENCES TECHNIQUES-SERIE ELECTROTECHNIQUE ET ENERGETIQUE, 2012, 57 (04): : 412 - 421
  • [34] Fault Ridethrough and Power Quality Improvement of Doubly-Fed Induction Generator based Wind Turbine System during Grid Fault with Novel Active Crowbar Protection Design
    Swain, Snehaprava
    Ray, Pravat Kumar
    PROCEEDINGS OF THE 2016 IEEE REGION 10 CONFERENCE (TENCON), 2016, : 2628 - 2633
  • [35] CHARACTERISTICS OF A DOUBLY-FED ASYNCHRONOUS GENERATOR APPLIED IN WIND TURBINES
    Milkic, Zarko
    Cukaric, Aleksandar
    Statkic, Sasa
    Maksimovic, Goran
    EKONOMIKA POLJOPRIVREDA-ECONOMICS OF AGRICULTURE, 2018, 65 (01): : 229 - 241
  • [36] Direct Torque Control of a Doubly-Fed Induction Generator for variable speed wind turbines
    Arnalte, S
    Burgos, JC
    Rodríguez-Amenedo, JL
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2002, 30 (02) : 199 - 216
  • [37] Wind turbines based on doubly fed induction generator under asymmetrical voltage dips
    Lopez, Jesus
    Gubia, Eugenio
    Sanchis, Pablo
    Roboam, Xavier
    Marroyo, Luis
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2008, 23 (01) : 321 - 330
  • [38] Doubly Fed Induction Generator Based Wind Turbine Systems Subject to Recurring Grid Faults
    Chen, Wenjie
    Blaabjerg, Frede
    Zhu, Nan
    Chen, Min
    Xu, Dehong
    2014 TWENTY-NINTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2014, : 3097 - +
  • [39] Diagnosis of the Doubly-Fed Induction Generator of a Wind Turbine
    Bennouna, O.
    Heraud, N.
    Camblong, H.
    Rodriguez, M.
    WIND ENGINEERING, 2005, 29 (05) : 431 - 447
  • [40] Virtual Synchronous Control Based on Control Winding Orientation for Brushless Doubly Fed Induction Generator (BDFIG) Wind Turbines Under Symmetrical Grid Faults
    Lu, Min
    Chen, Yu
    Zhang, Debin
    Su, Jingyuan
    Kang, Yong
    ENERGIES, 2019, 12 (02):