Analysis of the By-Pass Resistance of an Active Crowbar for Doubly-Fed Induction Generator Based Wind Turbines under Grid Faults

被引:0
|
作者
Zhang, Wei [1 ]
Zhou, Peng [1 ]
He, Yikang [1 ]
机构
[1] Zhejiang Univ, Coll Elect Engn, Hangzhou, Zhejiang, Peoples R China
关键词
Crowbar; by-pass resistance; doubly fed induction generator; wind turbine; grid voltage dip;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The doubly-fed induction generator (DFIG) based wind turbines of today are often equipped with a crowbar, which can be used to limit the inrush rotor current and protect the ac excitation converter from damage via a set of resistors that am connected to the rotor windings of the DFIG. When the rotor current becomes too high due to the severe grid voltage dips on the transmission line, the crowbar is activated and the rotor side converter is disconnected from the rotor windings at the same time, which makes the DFIG behave as a squirrel cage induction generator with increased rotor resistance. This paper analyzes the influence of the crowbar resistors on the electrical behavior of the DFIG during the grid voltage dips. Approximate expression of the fault stator and rotor currents are deduced from mathematical analysis and verified by simulation. Different crowbar by-pass resistances and their impacts on the maximal fault currents and electromagnetic torque am examined by simulations with different parameter sets of the DFIG. Based on the simulation results, the appropriate crowbar by-pass resistance can be effectively predicted.
引用
收藏
页码:2316 / 2321
页数:6
相关论文
共 50 条
  • [1] Single Grid Connection of Doubly-Fed Induction Generator for Wind Turbines
    Han, Yongsu
    Lee, Wook-Jin
    Ha, Jung-Ik
    2012 IEEE POWER ELECTRONICS AND MACHINES IN WIND APPLICATIONS (PEMWA), 2012,
  • [2] Analysis of fault current contribution of Doubly-Fed Induction Generator Wind Turbines during unbalanced grid faults
    El-Naggar, Ahmed
    Erlich, Istvan
    RENEWABLE ENERGY, 2016, 91 : 137 - 146
  • [3] Transient analysis and crowbar design of doubly-fed induction generator with crowbar protection under grid voltage dips
    Xiong, Wei
    Zou, Xudong
    Huang, Qingjun
    Liang, Zongze
    Chen, Jianqing
    Kang, Yong
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2015, 39 (11): : 117 - 125
  • [4] A control strategy for doubly-fed induction generator wind turbines under asymmetrical grid voltage conditions caused by faults
    Wang, Hongsheng
    Zhang, Wei
    Hu, Jiabing
    He, Yikang
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2010, 34 (04): : 97 - 102
  • [5] New Method of Setting the Maximum Crowbar Resistance for Doubly-Fed Induction Generators under Grid Faults
    Chongjarearn, Yutana
    2014 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY (ECTI-CON), 2014,
  • [6] Grid disturbance response of wind turbines equipped with induction generator and doubly-fed induction generator
    Thiringer, T
    Petersson, A
    Petru, T
    2003 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, : 1542 - 1547
  • [7] Doubly-fed induction generator torque in wind turbines
    Smajo, Jurica
    Vukadinovic, Dinko
    PROCEEDINGS OF THE 3RD IASME/WSEAS INTERNATIONAL CONFERENCE ON ENERGY & ENVIRONMENT: ENERGY AND ENVIRONMENT III, 2008, : 451 - +
  • [8] Power flow optimisation and grid integration of wind turbines with the doubly-fed induction generator
    Rabelo, B
    Hofmann, W
    2005 IEEE 36th Power Electronic Specialists Conference (PESC), Vols 1-3, 2005, : 2930 - 2936
  • [9] Electromechanical transient modeling of wind turbines based on doubly-fed induction generator
    Zi, Peng
    Zhou, Xiaoxin
    Tian, Fang
    An, Ning
    Hou, Junxian
    Zhang, Shi
    Tao, Xiangyu
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2015, 35 (05): : 1106 - 1114
  • [10] Wind turbines with doubly-fed induction generator systems with improved performance due to grid requirements
    Ehlert, D.
    Wrede, H.
    2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 3841 - 3847