Torsional properties of stainless-steel and nickel-titanium files after multiple autoclave sterilizations

被引:40
|
作者
Hilt, BR [1 ]
Cunningham, CJ [1 ]
Shen, CY [1 ]
Richards, N [1 ]
机构
[1] Univ Florida, Coll Dent, Endodont Resident Program, Gainesville, FL USA
关键词
D O I
10.1097/00004770-200002000-00004
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study tested the hypothesis that multiple sterilizations of endodontic stainless-steel and nickel-titanium files wilt lead to a continuous decrease in the resistance of files to separation by torsion. One hundred stainless-steel and 100 nickel-titanium #30 K-type files were divided into 20 groups of 10 and sterilized in increments of 10 cycles, using a full cycle and a fast cycle autoclave, These files were tested by twisting each of them in a clockwise direction until fracture (torque g-cm), Samples of the fractured flies were embedded in an epoxy resin and polished for Knoop hardness tests. In addition, the samples were chemically etched to reveal changes in microstructure, The findings of this study indicate that neither the number of sterilization cycles nor the type of autoclave sterilization used affects the torsional properties, hardness, and microstructure of stainless-steel and nickel-titanium files.
引用
收藏
页码:76 / 80
页数:5
相关论文
共 50 条
  • [41] Wear resistance of nickel-titanium endodontic files after surface treatment
    Alves-Claro, A. P. R.
    Claro, F. A. E.
    Uzumaki, E. T.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2008, 19 (10) : 3273 - 3277
  • [42] Defects in ProFile rotary nickel-titanium files after clinical use
    Ferreira, Manuel
    Ferreira, Hugo
    Oliveiros, Barbara
    Carrilho, Eunice
    ENDO-ENDODONTIC PRACTICE TODAY, 2012, 6 (02): : 113 - 117
  • [43] Comparison of root canal preparations and apical transportation between nickel-titanium rotary files and stainless steel hand instruments
    Varela Patino, Purificacion
    Pedrosa, Loreto
    Cantatore, Giuseppe
    Bahilo, Jose
    Ruiz-Pinon, Manuel
    Rivas, Berta
    Martin-Biedma, Benjamin
    ENDO-ENDODONTIC PRACTICE TODAY, 2012, 6 (01): : 45 - 49
  • [44] The use of computed tomography when comparing nickel-titanium and stainless steel files during preparation of simulated curved canals
    Garip, Y
    Günday, M
    INTERNATIONAL ENDODONTIC JOURNAL, 2001, 34 (06) : 452 - 457
  • [45] Assessment of the Mechanical Properties of ProTaper Next Nickel-Titanium Rotary Files
    Elnaghy, Amr M.
    Elsaka, Shaymaa E.
    JOURNAL OF ENDODONTICS, 2014, 40 (11) : 1830 - 1834
  • [46] Cyclic and Torsional Fatigue Resistance of Reciprocating Single Files Manufactured by Different Nickel-titanium Alloys
    Alcalde, Murilo P.
    Tanomaru-Filho, Mario
    Bramante, Clovis M.
    Duarte, Marco Antonio H.
    Guerreiro-Tanomaru, Juliane Maria
    Camilo-Pinto, Jader
    Reis So, Marcus Vinicius
    Vivan, Rodrigo Ricci
    JOURNAL OF ENDODONTICS, 2017, 43 (07) : 1186 - 1191
  • [47] Canal wall planning by engine-driven nickel-titanium instruments, compared with stainless-steel hand instrumentation
    Tucker, DM
    Wenckus, CS
    Bentkover, SK
    JOURNAL OF ENDODONTICS, 1997, 23 (03) : 170 - 173
  • [48] Cutting efficiency of stainless steel and nickel- titanium files.
    Leonardi, L
    Raiden, G
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B10 - B10
  • [49] Comparison of some physical properties of finger spreaders made of stainless steel or nickel-titanium alloys
    Hélio P. Lopes
    Mônica A. S. Neves
    Carlos N. Elias
    Edson J. L. Moreira
    José F. Siqueira
    Clinical Oral Investigations, 2011, 15 : 661 - 665
  • [50] Comparison of some physical properties of finger spreaders made of stainless steel or nickel-titanium alloys
    Lopes, Helio P.
    Neves, Monica A. S.
    Elias, Carlos N.
    Moreira, Edson J. L.
    Siqueira, Jose F., Jr.
    CLINICAL ORAL INVESTIGATIONS, 2011, 15 (05) : 661 - 665