Sparing of tissue by using micro-slit-beam radiation therapy reduces neurotoxicity compared with broad-beam radiation therapy

被引:21
|
作者
Mukumoto, Naritoshi [1 ]
Nakayama, Masao [1 ]
Akasaka, Hiroaki [1 ]
Shimizu, Yasuyuki [1 ]
Osuga, Saki [1 ]
Miyawaki, Daisuke [1 ]
Yoshida, Kenji [1 ]
Ejima, Yasuo [1 ]
Miura, Yasushi [2 ]
Umetani, Keiji [3 ]
Kondoh, Takeshi [4 ]
Sasaki, Ryohei [1 ]
机构
[1] Kobe Univ, Grad Sch Med, Div Radiat Oncol, Chuou Ku, 7-5-2 Kusunokicho, Kobe, Hyogo 6500017, Japan
[2] Kobe Univ, Grad Sch Hlth Sci, Dept Rehabil Sci, Kobe, Hyogo, Japan
[3] Japan Synchrotron Radiat Res Inst, Sayo, Hyogo, Japan
[4] Shinsuma Hosp, Dept Neurosurg, Kobe, Hyogo, Japan
关键词
microbeam; slit beam; synchrotron radiation; neurotoxicity; radiation therapy; CENTRAL-NERVOUS-SYSTEM; IN-VIVO; X-RAYS; STEREOTACTIC RADIOSURGERY; SYNCHROTRON-RADIATION; BRAIN RADIONECROSIS; MICROPLANAR BEAMS; RADIOTHERAPY; GLIOSARCOMAS; IRRADIATION;
D O I
10.1093/jrr/rrw065
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Micro-slit-beam radiation therapy (MRT) using synchrotron-generated X-ray beams allows for extremely high-dose irradiation. However, the toxicity of MRT in central nervous system (CNS) use is still unknown. To gather baseline toxicological data, we evaluated mortality in normal mice following CNS-targeted MRT. Male C57BL/6 J mice were head-fixed in a stereotaxic frame. Synchrotron X-ray-beam radiation was provided by the SPring-8 BL28B2 beam-line. For MRT, radiation was delivered to groups of mice in a 10 x 12 mm unidirectional array consisting of 25-mu m-wide beams spaced 100, 200 or 300 mu m apart; another group of mice received the equivalent broad-beam radiation therapy (BRT) for comparison. Peak and valley dose rates of the MRT were 120 and 0.7 Gy/s, respectively. Delivered doses were 96-960 Gy for MRT, and 24-120 Gy for BRT. Mortality was monitored for 90 days post-irradiation. Brain tissue was stained using hematoxylin and eosin to evaluate neural structure. Demyelination was evaluated by Kluver-Barrera staining. The LD50 and LD100 when using MRT were 600 Gy and 720 Gy, respectively, and when using BRT they were 80 Gy and 96 Gy, respectively. In MRT, mortality decreased as the center-to-center beam spacing increased from 100 mu m to 300 mu m. Cortical architecture was well preserved in MRT, whereas BRT induced various degrees of cerebral hemorrhage and demyelination. MRT was able to deliver extremely high doses of radiation, while still minimizing neuronal death. The valley doses, influenced by beam spacing and irradiated dose, could represent important survival factors for MRT.
引用
收藏
页码:17 / 23
页数:7
相关论文
共 50 条
  • [41] Normal tissue tolerance to external beam radiation therapy: Cardiac structures
    Doyen, J.
    Giraud, P.
    Belkacemi, Y.
    CANCER RADIOTHERAPIE, 2010, 14 (4-5): : 319 - 326
  • [42] IMAGING CHANGES IN PEDIATRIC PATIENTS TREATED WITH PROTON BEAM RADIATION THERAPY COMPARED TO INTENSITY MODULATED RADIATION THERAPY FOR INTRACRANIAL EPENDYMOMA
    Gunther, J.
    Sato, M.
    Chintagumpala, M.
    Jo, E.
    Paulino, A.
    Adesina, A.
    Ketonen, L.
    Jones, J.
    Su, J.
    Okcu, F.
    Khatua, S.
    Dauser, R.
    Whitehead, W.
    Weinberg, J.
    Mahajan, A.
    NEURO-ONCOLOGY, 2014, 16 : 120 - 120
  • [43] Imaging Changes in Pediatric Intracranial Ependymoma Patients Treated With Proton Beam Radiation Therapy Compared to Intensity Modulated Radiation Therapy
    Gunther, Jillian R.
    Sato, Mariko
    Chintagumpala, Murali
    Ketonen, Leena
    Jones, Jeremy Y.
    Allen, Pamela K.
    Paulino, Arnold C.
    Okcu, M. Fatih
    Su, Jack M.
    Weinberg, Jeffrey
    Boehling, Nicholas S.
    Khatua, Soumen
    Adesina, Adekunle
    Dauser, Robert
    Whitehead, William E.
    Mahajan, Anita
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (01): : 54 - 63
  • [44] An implantable radiation dosimeter for use in external beam radiation therapy
    Scarantino, CW
    Ruslander, DM
    Rini, CJ
    Mann, GG
    Nagle, HT
    Black, RD
    MEDICAL PHYSICS, 2004, 31 (09) : 2658 - 2671
  • [45] Multi-strip silicon sensors for beam array monitoring in micro-beam radiation therapy
    Alagoz, E.
    Brauer-Krisch, E.
    Bravin, A.
    Cornelius, I.
    Fournier, P.
    Hansen, T. E.
    Kok, A.
    Lerch, M.
    Monakhov, E.
    Morse, J.
    Pacifico, N.
    Petasecca, M.
    Povoli, M.
    Requard, H.
    Rozenfeld, A. D.
    Salome, M.
    Sandaker, H.
    Stugu, B.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (12): : 1795 - 1800
  • [46] Intraoperative electron radiation therapy combined with external beam radiation therapy and limb sparing surgery in extremity soft tissue sarcoma: a retrospective single center analysis of 183 cases
    Roeder, Falk
    Lehner, Burkhard
    Saleh-Ebrahimi, Ladan
    Hensley, Frank W.
    Ulrich, Alexis
    Alldinger, Ingo
    Mechtersheimer, Gunhild
    Huber, Peter E.
    Krempien, Robert
    Bischof, Marc
    Debus, Juergen
    Uhl, Matthias
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 (01) : 22 - 29
  • [47] Online Control of Micro-Beam Synchrotron Radiation Therapy Using Micro-Stripped Diamond Detectors
    Rosuel, N.
    Gallin-martel, M.
    Gallin-martel, L.
    Keshmiri, S.
    Krisch, M.
    Motte, J.
    Muraz, J.
    Ruat, M.
    Tribouilloy, L.
    Dauvergne, D.
    Adam, J. F.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [48] Dosimetric advantages of proton beam therapy compared to intensity-modulated radiation therapy for retroperitoneal chordoma
    Yu, Nathan Y.
    Vora, Sujay A.
    RARE TUMORS, 2019, 11
  • [49] LIMITED VOLUME RADIATION THERAPY WITH THE ELECTRON BEAM
    TAPLEY, ND
    FLETCHER, GH
    RADIOLOGY, 1964, 82 (02) : 327 - 328
  • [50] External Beam Radiation Therapy for Recalcitrant Dermatitis
    Sio, Terence T.
    Pittelkow, Mark R.
    Nagle, Marjorie A.
    Martenson, James A.
    ACTA DERMATO-VENEREOLOGICA, 2014, 94 (06) : 717 - 719