Influence of surface light scattering and glistenings of intraocular lenses on visual function 15 to 20 years after surgery

被引:11
|
作者
Oshika, Tetsuro [1 ]
Ando, Hiroshi [2 ]
Inoue, Yasushi [3 ]
Eguchi, Shuichiro [4 ]
Sato, Yukio [5 ]
Sugita, Toru [6 ]
Nishimura, Tomohisa [8 ]
Hayashi, Ken [9 ]
Fujita, Yoshifumi [10 ]
Miyata, Akira [11 ]
Sasaki, Noriyuki [7 ]
Miyata, Kazunori [12 ]
机构
[1] Univ Tsukuba, Fac Med, Dept Ophthalmol, 1-1-1 Tennoudai, Tsukuba, Ibaraki 3058575, Japan
[2] Ando Eye Clin, Kanagawa, Japan
[3] Inoue Eye Clin, Okayama, Japan
[4] Eguchi Eye Hosp, Hakodate, Hokkaido, Japan
[5] Yurinoki Clin, Nagano, Japan
[6] Sugita Eye Clin, Tokyo, Japan
[7] Alcon Japan Ltd, Tokyo, Japan
[8] Mikawa Eye Clin, Saga, Japan
[9] Hayashi Eye Hosp, Fukuoka, Japan
[10] Fujita Eye Clin, Tokushima, Japan
[11] Miyata Eye Clin, Hiroshima, Japan
[12] Miyata Eye Hosp, Miyazaki, Japan
来源
关键词
POSTERIOR CAPSULE OPACIFICATION; SUBSURFACE NANOGLISTENINGS; CONTRAST SENSITIVITY; CLINICAL-EVALUATION; TRANSMITTANCE; QUALITY; ACUITY;
D O I
10.1016/j.jcrs.2017.12.014
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the long-term influence of surface light scattering and glistenings of hydrophobic acrylic (Acrysof), silicone, and poly(methyl methacrylate) (PMMA) intraocular lenses (IOLs) on visual function. Setting: Eleven surgical sites, Japan. Design: Retrospective case series. Methods: Patients who had cataract surgery with implantation of a hydrophobic acrylic, silicone, or PMMA IOL from 1994 to 2000 were examined. Silicone and PMMA IOLs were not restricted to specific manufacturers or models. Patients were included if their corrected distance visual acuity (CDVA) within 3 months postoperatively (baseline CDVA) was 20/25 or better. The CDVA, contrast sensitivity, degree of surface light scattering measured with Pentacam densitometry, and glistening grades were recorded at the patient's latest visit. Results: Of the eyes, 31 had a hydrophobic acrylic IOL, 37 a silicone IOL, and 30 a PMMA IOL. Surface light scattering and glistenings were significantly greater with the hydrophobic acrylic IOL than with silicone and PMMA IOLs (P < .0001). The CDVA at the latest visit as well as the changes in CDVA from the baseline to the latest visit did not differ between the IOLs and was unaffected by surface light scattering and glistenings, as was the contrast sensitivity. Conclusions: The hydrophobic acrylic IOL was associated with a significantly greater level of surface light scattering and glistenings than the silicone IOLs and PMMA IOLs 15 to 20 years postoperatively. However, the optical phenomena within the optics of the hydrophobic acrylic IOL did not influence the patients' visual function. (c) 2018 ASCRS and ESCRS
引用
收藏
页码:219 / 225
页数:7
相关论文
共 50 条
  • [21] Visual outcome of multifocal intraocular lenses after retinal detachment surgery
    Freissinger, Sigrid Barbara
    Wolf, Armin
    Bayer, Iris
    Kern, Christoph
    Priglinger, Siegfried
    Keidel, Leonie Franziska
    Shajari, Mehdi
    Kreutzer, Thomas
    Vounotrypidis, Efstathios
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [22] The combination of diffractive and refractive multifocal intraocular lenses to provide full visual function after cataract surgery
    Huetz, Werner W.
    Bahner, Katarzyna
    Roehrig, Bernd
    Hengerer, Fritz
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2010, 20 (02) : 370 - 375
  • [23] Visual function after implantation of single-piece toric hydrophilic acrylic intraocular lenses with hydrophobic surface six months after cataract surgery
    Crnej, Alja
    Pfeifer, Vladimir
    ZDRAVNISKI VESTNIK-SLOVENIAN MEDICAL JOURNAL, 2012, 81 : I40 - I44
  • [24] Blue Light Filtration in Intraocular Lenses: Effects on Visual Function and Systemic Health
    Kohnen, Thomas
    Hammond, Billy R.
    CLINICAL OPHTHALMOLOGY, 2024, 18 : 1575 - 1586
  • [25] Do Blue-Light Filtering Intraocular Lenses Affect Visual Function?
    Lavric, Alenka
    Pompe, Manca Tekavcic
    OPTOMETRY AND VISION SCIENCE, 2014, 91 (11) : 1348 - 1354
  • [26] Comparison of postoperative surface light scattering in various hydrophobic acrylic intraocular lenses
    Lee, Jonghyun
    Lee, Do Hyung
    Kim, Jin Hyoung
    Choi, Hun Jin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [27] Visual Outcomes After Cataract Surgery: Multifocal Versus Monofocal Intraocular Lenses
    Shah, Sunil
    Peris-Martinez, Cristina
    Reinhard, Thomas
    Vinciguerra, Paolo
    JOURNAL OF REFRACTIVE SURGERY, 2015, 31 (10) : 658 - +
  • [28] Incidence of Dislocation of Intraocular Lenses and Pseudophakodonesis 10 Years after Cataract Surgery
    Monestam, Eva I.
    OPHTHALMOLOGY, 2009, 116 (12) : 2315 - 2320
  • [29] Visual function and patient experience after bilateral implantation of toric intraocular lenses
    Ahmed, Iqbal Ike K.
    Rocha, Guillermo
    Slomovic, Allan R.
    Climenhaga, Harold
    Gohill, Jit
    Gregoire, Alain
    Ma, Joseph
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (04): : 609 - 616
  • [30] Contrast sensitivity: determining the visual quality and function of cataract, intraocular lenses and refractive surgery
    Ginsburg, AR