Planar Differential Mobility Analyzer with a Resolving Power of 110

被引:25
|
作者
Amo-Gonzalez, Mario [1 ]
Perez, Sergio [1 ]
机构
[1] SEADM, Parque Tecnol Boecillo 205, Valladolid 47151, Spain
关键词
SPECTROMETRY; SEPARATION; IONS;
D O I
10.1021/acs.analchem.8b00579
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Planar differential mobility analyzers (DMAs) have previously achieved resolving powers of 60-80 in air or N-2 at the mobility of the tetraheptylammonium ion (THA(+), similar to 0.97 cm(2)/V/s). For unclear reasons, this performance is considerably below the theoretical limit. In this work, a performance close to this ideal limit is attained in SEADM's P5 DMA via improved flow laminarization, under otherwise the same flow conditions as in prior work. The new laminarizer remains effective at unusually large gas velocities (reached with two blowers in series), yielding a resolving power of 110. The selectivity of the improved DMA combined with a mass spectrometer was assessed by the analysis of a real sample of extra virgin olive oil.
引用
收藏
页码:6735 / 6741
页数:7
相关论文
共 50 条
  • [41] Classification and characterization of gold and nickel nanoparticles with a differential mobility analyzer
    Naono, Yasutomo
    Kawabata, Sayuri
    Huh, Seung H.
    Nakajima, Atsushi
    SCIENCE AND TECHNOLOGY OF ADVANCED MATERIALS, 2006, 7 (02) : 209 - 215
  • [42] Radial Differential Mobility Analyzer for One Nanometer Particle Classification
    Brunelli, N. A.
    Flagan, R. C.
    Giapis, K. P.
    AEROSOL SCIENCE AND TECHNOLOGY, 2009, 43 (01) : 53 - 59
  • [43] Sizing of colloidal nanoparticles by electrospray and differential mobility analyzer methods
    Lenggoro, IW
    Xia, B
    Okuyama, K
    de la Mora, JF
    LANGMUIR, 2002, 18 (12) : 4584 - 4591
  • [44] Diffusion Distortions in a Differential Mobility Analyzer with Inclined Electric Field
    Salm, J.
    Horrak, U.
    AEROSOL SCIENCE AND TECHNOLOGY, 2009, 43 (03) : 227 - 231
  • [45] Development of a multiple-stage differential mobility analyzer (MDMA)
    Chen, Da-Ren
    Li, Weiling
    Cheng, Meng-Dawn
    AEROSOL SCIENCE AND TECHNOLOGY, 2007, 41 (02) : 217 - 230
  • [46] Changes in the shape and mobility of colloidal gold nanorods with electrospray and differential mobility analyzer methods
    Song, DK
    Lenggoro, IW
    Hayashi, Y
    Okuyama, K
    Kim, SS
    LANGMUIR, 2005, 21 (23) : 10375 - 10382
  • [47] Resolving powers of >7900 using linked scans: how well does resolving power describe the separation capability of differential ion mobility spectrometry
    Santiago, Brandon G.
    Harris, Rachel A.
    Isenberg, Samantha L.
    Glish, Gary L.
    ANALYST, 2015, 14 (20) : 6871 - 6878
  • [48] Scaling of the resolving power and sensitivity for planar FAIMS and mobility-based discrimination in flow- and field-driven analyzers
    Shvartsburg, Alexandre A.
    Smith, Richard D.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2007, 18 (09) : 1672 - 1681
  • [49] Expanded theory for the resolving power of a linear ion mobility spectrometer
    Spangler, GE
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 220 (03) : 399 - 418
  • [50] Enhanced Resolving Power by Moving Field Ion Mobility Spectrometry
    Bohnhorst, Alexander
    Hitzemann, Moritz
    Lippmann, Martin
    Kirk, Ansgar T.
    Zimmermann, Stefan
    ANALYTICAL CHEMISTRY, 2020, 92 (19) : 12967 - 12974