Bypass line assisted start-up of a loop heat pipe with a flat evaporator

被引:19
|
作者
Boo, Joon Hong [1 ]
Jung, Eui Guk [2 ]
机构
[1] Korea Aerosp Univ, Sch Aerosp & Mech Engn, Goyang 412791, Gyeonggi Do, South Korea
[2] Korea Aerosp Univ, Grad Sch, Dept Aerosp & Mech Engn, Goyang 412791, Gyeonggi Do, South Korea
关键词
Loop heat pipe; Flat evaporator; Start-up; Bypass line; MENISCUS TYPE EVAPORATOR; THERMAL PERFORMANCE;
D O I
10.1007/s12206-009-0405-5
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Loop heat pipes often experience start-up problems especially under low thermal loads. A bypass line was installed between the evaporator and the liquid reservoir to alleviate the difficulties associated with start-up of a loop heat pipe with flat evaporator. The evaporator and condenser had dimensions of 40 mm (W) by 50 mm (L). The wall and tube materials were stainless steel and the working fluid was methanol. Axial grooves were provided in the flat evaporator to serve as vapor passages. The inner diameters of liquid and vapor transport lines were 2 mm and 4 mm, respectively, and the length of the two lines was 0.5 m each. The thermal load range was up to 130 W for horizontal alignment with the condenser temperature of 10A degrees C. The experimental results showed that the minimum thermal load for start-up was lowered by 37% when the bypass line was employed.
引用
收藏
页码:1613 / 1619
页数:7
相关论文
共 50 条
  • [21] Flat plate loop heat pipe with a novel evaporator structure
    Tsai, MC
    Yu, CS
    Kang, SW
    TWENTY-FIRST ANNUAL IEEE SEMICONDUCTOR THERMAL MEASUREMENT AND MANAGEMENT SYMPOSIUM, PROCEEDINGS 2005, 2005, : 187 - 190
  • [22] Experimental investigation of the miniture loop heat pipe with flat evaporator
    Singh, Randeep
    Akbarzadeh, Aliakbar
    Mochizuki, Mastaka
    Nguyen, Thang
    Wuttijumnong, Vijit
    Advances in Electronic Packaging 2005, Pts A-C, 2005, : 697 - 702
  • [23] Operational characteristics of a miniature loop heat pipe with flat evaporator
    Singh, Randeep
    Akbarzadeh, Aliakbar
    Mochizuki, Masataka
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2008, 47 (11) : 1504 - 1515
  • [24] Complete analytical model of a loop heat pipe with a flat evaporator
    Siedel, Benjamin
    Sartre, Valerie
    Lefevre, Frederic
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2015, 89 : 372 - 386
  • [25] An experimental investigation of miniature loop heat pipe with flat evaporator
    Gai, Dongxing
    Liu, Wei
    Liu, Zhichun
    Yang, Jinguo
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 3960 - 3963
  • [26] Experimental investigation for the loop heat pipe with a bifacial flat evaporator
    Wang, Tingting
    Zhao, Jing
    Liu, Wei
    Ma, Lei
    Liu, Zhichun
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2024, 200
  • [27] Experimental study of heat transfer and start-up of loop heat pipe with multiscale porous wicks
    Ji, Xianbing
    Wang, Ye
    Xu, Jinliang
    Huang, Yanping
    APPLIED THERMAL ENGINEERING, 2017, 117 : 782 - 798
  • [28] Start-up performance of a loop heat pipe with variable heating patterns and periodic cycles
    Wang, G
    Mishkinis, D
    MacDonald, E
    Kaya, T
    Nikanpour, D
    SPACE TECHNOLOGY AND APPLICATIONS INTERNATIONAL FORUM-STAIF 2005, 2005, 746 : 106 - 113
  • [29] The start-up characteristics of a novel loop heat pipe with stainless steel capillary wick
    Tian, Tao
    Li, Haoyang
    Zhang, Wen
    Lai, Qingzhi
    Xie, Yinmo
    Tan, Jianyu
    APPLIED THERMAL ENGINEERING, 2025, 258
  • [30] Experimental studies on the transient characteristics and start-up behaviour of a miniature loop heat pipe
    Nashine, Chandan
    Pandey, Manmohan
    Baraya, Kamlesh K.
    APPLIED THERMAL ENGINEERING, 2025, 259