A chloride ion-selective solvent polymeric membrane electrode based on a hydrogen bond forming ionophore

被引:152
|
作者
Xiao, KP [1 ]
Buhlmann, P [1 ]
Nishizawa, S [1 ]
Amemiya, S [1 ]
Umezawa, Y [1 ]
机构
[1] UNIV TOKYO,SCH SCI,DEPT CHEM,TOKYO 113,JAPAN
关键词
FIELD-EFFECT TRANSISTORS; NEUTRAL CARRIERS; GAS-PHASE; ANION SELECTIVITIES; AMMONIUM-COMPOUNDS; ORGANIC-COMPOUNDS; HALIDE ANIONS; RECOGNITION; SITES; RECEPTORS;
D O I
10.1021/ac961035d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A chloride-selective solvent polymeric membrane electrode based on a neutral hydrogen bond forming ionophore, poly(vinyl chloride) (PVC), the plasticizer 2-nitrophenyl octyl ether (o-NPOE), and cationic sites (50 mol %, relative to the ionophore) is described. At pH 7.0 (HEPES buffer), this electrode responds to chloride in a linear range from 10(-5) to 10(-2) M with a slope of (-54.0 +/- 1.0) mV/decade and a detection limit of (6.5 +/- 3.0) x 10(-6) M. As compared to conventional anion-exchanger electrodes, the interference of SCN-, Br-, NO3-, I-, and even salicylate is considerably reduced, as shown by the selectivity coefficients determined with the matched potential method (MPM) in the chloride concentration range 10(-2.34)-10(-2.04) M (log KPCl,jpot (MPM): Sal(-), +1.8; SCN-, +1.6; NO3-, +0.7; I-, +0.5; Br-, +0.4). Because the discrimination of the more hydrophilic anions SO42-, HSO3-/SO32-, OAc-, HCO3-, and H2PO4-/HPO42- is too large for a determination of accurate selectivity coefficients in this high chloride concentration range, corresponding values for the range 10(-5.00)-10(-4.70) M Cl- have been determined (log K-Cl,j(pot) (MPM): SO42-, -1.2; HSO3-/SO32-, -2.0; OAC-, -2.3; HCO3-, -2.6; H2PO4-/HPO42-, < -3.5), showing here, too, a good selectivity for Cl-. The chloride ion concentration in certified control horse serum was determined by the standard addition method as 102.1 mM with a coefficient of variation of 0.42% (n = 6). This result is in excellent agreement with the certified value of 102.3 mM, as determined by coulometry, and demonstrates the applicability of this sensor for measurements in biological samples. The selectivity upon storage of the electrode in buffer solution for 4 weeks decreases but is stilt considerably better than that for a freshly prepared anion-exchanger electrode.
引用
收藏
页码:1038 / 1044
页数:7
相关论文
共 50 条
  • [21] A diethylenetriamine pentaacetic acid ion-selective plastic membrane electrode based on tricaprylylmethylammonium chloride
    Wen, ML
    Peng, LJ
    Yin, CX
    Wang, CY
    SOUTH AFRICAN JOURNAL OF CHEMISTRY-SUID-AFRIKAANSE TYDSKRIF VIR CHEMIE, 1998, 51 (04): : 171 - 173
  • [22] ION-SELECTIVE ELECTRODE ANALYZER FOR MONITORING GASEOUS HYDROGEN-CHLORIDE
    CONVERSE, JG
    FOWLER, L
    EMERY, EM
    ISA TRANSACTIONS, 1976, 15 (03) : 220 - 226
  • [23] Liquid Polymeric Membrane Composition of Ion Selective Electrode Based on Thiazole-4-carboxamide as Ionophore
    Jamil, Noor Wahidah Zainol
    Yahya, Muhd Zu Azhan
    Jumal, Juliana
    Kasim, Noor Azilah Mohd
    MATERIALS CHARACTERIZATION USING X-RAYS AND RELATED TECHNIQUES, 2019, 2068
  • [24] BEHAVIOR OF A POLYMERIC LIQUID MEMBRANE ION- SELECTIVE ELECTRODE FOR CHLORIDE ION
    Arada Perez, M. De Los A.
    Yazdani-Pedram, M.
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2013, 58 (04): : 1957 - 1958
  • [25] CHLORIDE DETERMINATION IN FOODS WITH ION-SELECTIVE ELECTRODE AFTER ISOLATION AS HYDROGEN-CHLORIDE
    CERKLEWSKI, FL
    RIDLINGTON, JW
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1987, 70 (05): : 924 - 926
  • [26] Cd (II) Ion-Selective Electrode Based On 2-Acetylthiophene Semicarbazone In Polymeric Membrane
    Mohan, C.
    Sharma, K.
    Chandra, S.
    CHEMICAL SENSORS 12: CHEMICAL AND BIOLOGICAL SENSORS AND ANALYTICAL SYSTEMS, 2016, 75 (16): : 319 - 327
  • [27] SULFATE ION-SELECTIVE MEMBRANE ELECTRODE
    RECHNITZ, GA
    MOHAN, MS
    FRICKE, GH
    ANALYTICAL CHEMISTRY, 1972, 44 (06) : 1098 - &
  • [28] Voltammetric determination of phosphates using ion-selective electrode based on organotin ionophore
    Martynov, Leonid Yu.
    Sergeeva, Anastasia S.
    Sakharov, Konstantin A.
    Shkinev, Valery M.
    Yashtulov, Nikolai A.
    Zaitsev, Nikolai K.
    MICROCHEMICAL JOURNAL, 2023, 191
  • [29] WATER AND THE ION-SELECTIVE ELECTRODE MEMBRANE
    HARRISON, DJ
    LI, XZ
    PETROVIC, S
    ACS SYMPOSIUM SERIES, 1992, 487 : 292 - 300
  • [30] Basic response principles of voltammetric ion-selective solvent polymeric membrane sensors
    Bakker, E
    Jadhav, S