Contaminated feeding bottles: The source of an outbreak of Pseudomonas aeruginosa infections in a neonatal intensive care unit

被引:27
|
作者
Sanchez-Carrillo, Carlos [1 ]
Padilla, Belen [1 ]
Marin, Mercedes [1 ]
Rivera, Marisa [1 ]
Cercenado, Emilia [1 ]
Vigil, Dolores [2 ]
Sanchez-Luna, Manuel [3 ]
Bouza, Emilio [1 ]
机构
[1] Hosp Gen Univ Gregorio Maranon, Serv Microbiol, Clin & E Infecciosas, Madrid 28007, Spain
[2] Hosp Gen Univ Gregorio Maranon, Serv Med Prevent, Madrid 28007, Spain
[3] Hosp Gen Univ Gregorio Maranon, Serv Neonatol, Madrid 28007, Spain
关键词
NOSOCOMIAL INFECTIONS; EPIDEMIOLOGY; TRANSMISSION; HANDS;
D O I
10.1016/j.ajic.2008.04.259
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Outbreaks of Pseudomonas aeruginosa have been reported in relationship with contamination of staff fingernails, hands, water baths, hand lotions and others. To our knowledge, contamination of milk and feeding bottles as a source of an outbreak of P aeruginosa infections has not been reported. The incidence of P aeruginosa infection/colonization in our neonatal intensive care unit increased from 1.9 per 1000 patient-days in August 2004 to 8,8 per 1000 patient-days in September 2004. Methods: Samples were collected including hand and body lotions, water from the incubator humidifying system, the health care worker hands, and the feeding bottle preparation room. Strains were epidemiologically characterized by pulsed-field gel electrophoresis of Spel-digested genomic DNA. P aeruginosa was isolated from a total of 30 neonates during the period September 2004 to December 2004. Results: All cultures (139) of hand and body lotions, water from the incubator humidifying system, and hands of health care personnel were negative. Nine out of 48 samples collected from the feeding bottle preparation room were positive for P aeruginosa (6 samples of in-house prepared milk and 3 samples of water from dishwashers). Pulsed-held gel electrophoresis with Spel showed that the strains isolated from neonates and from environmental samples were identical. Discontinuation of in-house preparation of feeding bottles and incorporation of unidose milk bottles stopped the outbreak. Conclusion: The preparation and solution of milk from multidose powder preparation may be a source of P aeruginosa infections in a neonatal intensive care unit. The use of manufactured, nonmanipulated, unidose feeding bottles should be considered more adequate. Copyright (C) 2009 Association for Professionals in Infection Control and Epidemiology, Inc.
引用
收藏
页码:150 / 154
页数:5
相关论文
共 50 条
  • [41] Outbreak of Candida parapsilosis in a neonatal intensive care unit: a health care workers source
    Hernandez-Castro, Rigoberto
    Arroyo-Escalante, Sara
    Carrillo-Casas, Erika M.
    Moncada-Barron, David
    Alvarez-Verona, Elizabeth
    Hernandez-Delgado, Lorena
    Torres-Narvaez, Patricia
    Lavalle-Villalobos, Antonio
    EUROPEAN JOURNAL OF PEDIATRICS, 2010, 169 (07) : 783 - 787
  • [42] Outbreak of Candida parapsilosis in a neonatal intensive care unit: a health care workers source
    Rigoberto Hernández-Castro
    Sara Arroyo-Escalante
    Erika M. Carrillo-Casas
    David Moncada-Barrón
    Elizabeth Álvarez-Verona
    Lorena Hernández-Delgado
    Patricia Torres-Narváez
    Antonio Lavalle-Villalobos
    European Journal of Pediatrics, 2010, 169 : 783 - 787
  • [43] Flavobacterium sepsis outbreak due to contaminated distilled water in a neonatal intensive care unit
    Mosayebi, Z.
    Movahedian, A. H.
    Soori, T.
    JOURNAL OF HOSPITAL INFECTION, 2011, 78 (03) : 214 - 215
  • [44] Serratia marcescens outbreak in a neonatal intensive care unit associated with contaminated donor milk
    Bechmann, Lukas
    Boettger, Ralf
    Baier, Claas
    Tersteegen, Aljoscha
    Bauer, Katja
    Kaasch, Achim J.
    Geginat, Gernot
    INFECTION CONTROL & HOSPITAL EPIDEMIOLOGY, 2023, 44 (06) : 891 - 897
  • [45] Outbreak investigation in a neonatal intensive care unit
    Haas, JP
    Trezza, LA
    SEMINARS IN PERINATOLOGY, 2002, 26 (05) : 367 - 378
  • [46] An Enterobacter outbreak on a neonatal Intensive care unit
    Eckmanns, T.
    Jansen, A.
    Geipel, U.
    Herrmann, M.
    von Mueller, L.
    Jung, W.
    Haber, M.
    Thome-Granz, S.
    Hermes, J.
    GESUNDHEITSWESEN, 2011, 73 (03) : 184 - 184
  • [47] An outbreak of influenza A in a neonatal intensive care unit
    Cunney, RJ
    Bialachowski, A
    Thornley, D
    Smaill, FM
    Pennie, RA
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2000, 21 (07): : 449 - 454
  • [48] Outbreak of scabies in a neonatal intensive care unit
    Vijayan, Vini
    Marrero, Elizabeth
    Gaspar, Anna
    Wisdom, Christy
    Honeycutt, Michele D.
    Linam, W. Matthew
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2019, 40 (05): : 613 - 614
  • [49] Pseudomonas aeruginosa Outbreak in a Neonatal Intensive Care Unit Attributed to Hospital Tap Water: Methodological and Statistical Issues to Avoid Misinterpretation
    Safiri, Saeid
    Ayubi, Erfan
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2017, 38 (09): : 1126 - 1127
  • [50] RSV outbreak in a neonatal intensive care unit
    Kokstein, Z
    Basek, P
    Kalous, P
    Vanícek, H
    Pozler, O
    Stepánová, P
    Pozlerová, E
    Horácek, J
    Plísková, L
    Pesavová, L
    PERINATOLOGY 2001, VOLS 1 AND 2, 2001, : 837 - 841