Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in an STI population: performances of the Presto CT-NG assay, the Lightmix Kit 480 HT CT/NG and the COBAS Amplicor with urine specimens and urethral/cervicovaginal samples

被引:8
|
作者
Schuurs, T. A. [1 ]
Verweij, S. P. [2 ]
Weel, J. F. L. [1 ]
Ouburg, S. [2 ]
Morre, S. A. [2 ,3 ]
机构
[1] Izore, Ctr Infect Dis Friesland, Leeuwarden, Netherlands
[2] Vrije Univ Amsterdam, Med Ctr, Dept Med Microbiol & Infect Control, Lab Immunogenet, Amsterdam, Netherlands
[3] Univ Maastricht, Fac Hlth Med & Life Sci, Dept Genet & Cell Biol, Res Inst GROW,Inst Publ Hlth Genom, Maastricht, Netherlands
来源
BMJ OPEN | 2013年 / 3卷 / 12期
关键词
PCR; PREVALENCE; INFECTION; WOMEN;
D O I
10.1136/bmjopen-2013-003607
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: This study assessed the performances of the Presto CT-NG assay, the Lightmix Kit 480 HT CT/NG and the COBAS Amplicor for Chlamydia trachomatis and Neisseria gonorrhoeae detection. Design: A cross-sectional study design. Setting: Izore, Centre for Diagnosing Infectious Diseases in Friesland, the Netherlands, tested samples sent from regional sexually transmitted infection (STI) outpatient clinics and regional hospitals from the province Friesland, the Netherlands. Participants: Samples were collected from 292 men and 835 women. These samples included 560 urine samples and 567 urethral/cervicovaginal samples. Primary and secondary outcome measures: The primary outcome measure is C trachomatis infection. No secondary outcome measures are available. Results: The sensitivity, specificity, positive predicative value (PPV) and negative predictive value (NPV) for C trachomatis detection in urine samples using the Presto CT-NG assay were 100%, 99.8%, 98.1% and 100%, respectively; for the Lightmix Kit 480 HT CT/NG: 94.2%, 99.8%, 96.1% and 99.4%, respectively; for the COBAS Amplicor: 92.3%, 99.6%, 96% and 99.2%, respectively. The sensitivity, specificity, PPV and NPV for C trachomatis detection in urethral/cervicovaginal swabs using the Presto CT-NG assay and the COBAS Amplicor were 100%, 99.8%, 97.7% and 100%, respectively; for the Lightmix Kit 480 HT CT/NG: 100%, 99.6%, 97.7% and 100%, respectively. Calculations for N gonorrhoeae could not be made due to a low prevalence. Conclusions: All three assays had a high sensitivity, specificity, PPV and NPV for C trachomatis, with best performance for the Presto CT-NG assay.
引用
收藏
页数:4
相关论文
共 37 条
  • [1] Chlamydia trachomatis and Neisseria gonorrhoeae (CT/NG) Detection in SurePath and ThinPrep Specimens Using Abbot RealTime CT/NG Assay
    Lucic, D.
    Eisenhut, C.
    Cloherty, G.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2013, 15 (06): : 896 - 896
  • [2] A profile of the cobas® CT/NG assay on the cobas® 6800/8800 system for detection of Chlamydia trachomatis and Neisseria gonorrhoeae
    Van Der Pol, Barbara
    EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2020, 20 (04) : 375 - 380
  • [3] Evaluation of the Roche cobas® CT/NG Test for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in Male Urine
    Taylor, Stephanie N.
    Liesenfeld, Oliver
    Lillis, Rebecca A.
    Body, Barbara A.
    Nye, Melinda
    Williams, James
    Eisenhut, Carol
    Hook, Edward W., III
    Van der Pol, Barbara
    SEXUALLY TRANSMITTED DISEASES, 2012, 39 (07) : 543 - 549
  • [4] Detection of Neisseria gonorrhoeae or Chlamydia trachomatis from oral wash specimens using the Abbott RealTime CT/NG assay and the Cobas 4800 CT/NG assay: A prospective study
    Matsumoto, Masahiro
    Hamasuna, Ryoichi
    Le, Phuong Thi
    Fujimoto, Naohiro
    Matsumoto, Tetsuro
    JOURNAL OF INFECTION AND CHEMOTHERAPY, 2022, 28 (04) : 480 - 485
  • [5] Evaluation of the cobas 4800 CT/NG Test for detecting Chlamydia trachomatis and Neisseria gonorrhoeae DNA in urogenital swabs and urine specimens
    Parra-Sanchez, Manuel
    Carlos Palomares, Jose
    Bernal, Samuel
    Trinidad Gonzalez, Maria
    Sivianes, Nieves
    Perez, Luis
    Pueyo, Isabel
    Martin-Mazuelos, Estrella
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2012, 74 (04) : 338 - 342
  • [6] Performance evaluation of the PelvoCheck CT/NG test kit for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae
    Meyer, Thomas
    Kios, Christian
    Kofler, Regina
    Kilic, Annett
    Haenel, Kristina
    BMJ OPEN, 2016, 6 (01):
  • [7] Comparison of analytical performances of the Roche Cobas 6800 CT/NG assay with the Abbott m2000 Real Time CT/NG assay for detecting Chlamydia trachomatis and Neisseria gonorrhoeae
    Cherkaoui, Abdessalam
    Renzi, Gesuele
    Mombelli, Michele
    Jaton, Katia
    Yerly, Sabine
    Vuilleumier, Nicolas
    Schrenzel, Jacques
    JOURNAL OF MEDICAL MICROBIOLOGY, 2019, 68 (02) : 197 - 200
  • [8] Comparison of GMT presto assay and Roche cobase® 4800 CT/NG assay for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in dry swabs
    de Waaij, Dewi J.
    Dubbink, Jan Henk
    Peters, Remco P. H.
    Ouburg, Sander
    Morre, Servaas A.
    JOURNAL OF MICROBIOLOGICAL METHODS, 2015, 118 : 70 - 74
  • [9] Meta-analysis of the Cepheid Xpert® CT/NG assay for extragenital detection of Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) infections
    Bristow, Claire C.
    Morris, Sheldon R.
    Little, Susan J.
    Mehta, Sanjay R.
    Klausner, Jeffrey D.
    SEXUAL HEALTH, 2019, 16 (04) : 314 - 319
  • [10] Processing Optimization of Chlamydia trachomatis and Neisseria gonorrhoeae Simulated Urine Samples from Proficiency Testing Panels on the Cobas CT/NG Test
    Engstrom-Melnyk, J.
    Geraldo, V.
    Rodriguez, P.
    Ruiz, E.
    Osiecki, J.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2013, 15 (06): : 894 - 894