Evaluation of the Roche cobas® CT/NG Test for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in Male Urine

被引:33
|
作者
Taylor, Stephanie N. [1 ]
Liesenfeld, Oliver [2 ]
Lillis, Rebecca A. [1 ]
Body, Barbara A. [3 ]
Nye, Melinda [3 ]
Williams, James [4 ]
Eisenhut, Carol [5 ]
Hook, Edward W., III [6 ,7 ]
Van der Pol, Barbara [4 ,8 ]
机构
[1] Louisiana State Univ, Hlth Sci Ctr, New Orleans, LA USA
[2] Roche Mol Syst, Pleasanton, CA USA
[3] Lab Corp Amer, Burlington, NC USA
[4] Indiana Univ Sch Med, Indianapolis, IN USA
[5] DCL Labs Lab Corp Amer, Indianapolis, IN USA
[6] Univ Alabama Birmingham, Birmingham, AL USA
[7] Jefferson Cty Hlth Dept, Birmingham, AL USA
[8] Indiana Univ, Sch Publ Hlth, Bloomington, IN USA
关键词
MULTICENTER EVALUATION; INFECTIONS; AMPLICOR;
D O I
10.1097/OLQ.0b013e31824e26ff
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background: The Roche cobas((R)) CT/NG test (c4800), performed on the cobas 4800 system, is a new diagnostic assay using an automated workstation to isolate nucleic acids from clinical specimens and a real time instrument for the detection of Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG). This study compared the performance characteristics of the c4800 with the Becton Dickinson ProbeTec (TM) CT/GC Q(x) assay (Q(x)) and Gen-Probe((R)) Aptima Combo 2 (AC2) assay for the detection of CT and NG in male urine using patient-infected-status (PIS). Methods: Urine and urethral swabs were obtained from men attending STD, family planning, or OB/GYN clinics from 11 geographically distinct locations. Aliquot order was randomized for urine specimens between AC2, c4800, and Q(x). Urethral swabs were randomized between AC2 and Q(x). Urethral swabs were only used to define PIS and were not tested on the c4800. A participant was considered infected if the 2 comparator assays with different molecular targets had positive results from either sample type. Results: A total of 790 men were screened, with 768 evaluable for CT and NG. Symptoms were reported in 296 (38.5%) participants. For urine, the overall sensitivity and specificity of the c4800 assay for CT were 97.6% and 99.5%, respectively, when compared with PIS. Sensitivity and specificity for NG were 100% and 99.7%, respectively. Conclusions: The c4800 has excellent sensitivity and specificity for male urine specimens when compared with PIS. Assay performance was similar in symptomatic and asymptomatic men and was equivalent to nucleic acid amplification tests that are currently on the market.
引用
收藏
页码:543 / 549
页数:7
相关论文
共 50 条
  • [1] Evaluation of the cobas 4800 CT/NG test for detecting Chlamydia trachomatis and Neisseria gonorrhoeae
    Rockett, Rebecca
    Goire, Namraj
    Limnios, Athena
    Turra, Mark
    Higgens, Geoffrey
    Lambert, Stephen B.
    Bletchly, Cheryl
    Nissen, Michael D.
    Sloots, Theo P.
    Whiley, David M.
    SEXUALLY TRANSMITTED INFECTIONS, 2010, 86 (06) : 470 - 473
  • [2] Evaluation of the cobas 4800 CT/NG Test for detecting Chlamydia trachomatis and Neisseria gonorrhoeae DNA in urogenital swabs and urine specimens
    Parra-Sanchez, Manuel
    Carlos Palomares, Jose
    Bernal, Samuel
    Trinidad Gonzalez, Maria
    Sivianes, Nieves
    Perez, Luis
    Pueyo, Isabel
    Martin-Mazuelos, Estrella
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2012, 74 (04) : 338 - 342
  • [3] Evaluation of the Performance of the Cobas CT/NG Test for Use on the Cobas 6800/8800 Systems for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in Male and Female Urogenital Samples
    Van Der Pol, Barbara
    Fife, Kenneth
    Taylor, Stephanie N.
    Nye, Melinda B.
    Chavoustie, Steven E.
    Eisenberg, David L.
    Crane, LaShonda
    Hirsch, Gregory
    Arcenas, Rodney
    Marlowe, Elizabeth M.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2019, 57 (04)
  • [4] EVALUATION OF THE ROCHE COBAS 4800 FOR THE DETECTION OF CHLAMYDIA TRACHOMATIS AND NEISSERIA GONORRHOEAE USING ENDOCERVICAL SPECIMENS
    Pantone, A.
    Van der Pol, B.
    Lillis, R.
    Loyd, B.
    Nye, M. B.
    Taylor, S.
    SEXUALLY TRANSMITTED INFECTIONS, 2011, 87 : A278 - A279
  • [5] A profile of the cobas® CT/NG assay on the cobas® 6800/8800 system for detection of Chlamydia trachomatis and Neisseria gonorrhoeae
    Van Der Pol, Barbara
    EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2020, 20 (04) : 375 - 380
  • [6] Performance evaluation of the PelvoCheck CT/NG test kit for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae
    Meyer, Thomas
    Kios, Christian
    Kofler, Regina
    Kilic, Annett
    Haenel, Kristina
    BMJ OPEN, 2016, 6 (01):
  • [7] CLINICAL EVALUATION OF THE PELVOCHECK® CT/NG FOR THE DETECTION OF CHLAMYDIA TRACHOMATIS AND NEISSERIA GONORRHOEAE
    Kilic, A.
    Kofler, R.
    Haenel, K.
    Meyer, T.
    SEXUALLY TRANSMITTED INFECTIONS, 2013, 89 : A92 - A93
  • [8] Evaluation of COBAS AMPLICOR (Roche):: Accuracy in detection of Chlamydia trachomatis and Neisseria gonorrhoeae by coamplification of endocervical specimens
    Livengood, CH
    Wrenn, JW
    JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (08) : 2928 - 2932
  • [9] Vaginal Swabs Are the Optimal Specimen for Detection of Genital Chlamydia trachomatis or Neisseria gonorrhoeae Using the Cobas 4800 CT/NG Test
    Van Der Pol, Barbara
    Taylor, Stephanie N.
    Liesenfeld, Oliver
    Williams, James A.
    Hook, Edward W., III
    SEXUALLY TRANSMITTED DISEASES, 2013, 40 (03) : 247 - 250
  • [10] Processing Optimization of Chlamydia trachomatis and Neisseria gonorrhoeae Simulated Urine Samples from Proficiency Testing Panels on the Cobas CT/NG Test
    Engstrom-Melnyk, J.
    Geraldo, V.
    Rodriguez, P.
    Ruiz, E.
    Osiecki, J.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2013, 15 (06): : 894 - 894