The Spectrum-Beamformer for Conventional B-Mode Ultrasound Imaging System: Principle, Validation, and Robustness

被引:2
|
作者
Jiang, Chen [1 ]
Liu, Chengcheng [2 ,3 ]
Zhan, Yiqiang [1 ]
Ta, Dean [2 ,3 ,4 ]
机构
[1] Fudan Univ, Micronano Syst Ctr, Sch Informat Sci & Technol, 220 Handan Rd, Shanghai 200433, Peoples R China
[2] Fudan Univ, Acad Engn & Technol, 220 Handan Rd, Shanghai 200433, Peoples R China
[3] Shanghai Key Lab Med Image Comp & Comp Assisted I, Shanghai, Peoples R China
[4] Fudan Univ, Ctr Biomed Engn, Sch Informat Sci & Technol, 220 Handan Rd, Shanghai 200433, Peoples R China
关键词
Focused ultrasound imaging; spectrum domain beamformer; virtual sources; full-matrix capture-stolt; computational efficiency; RECONSTRUCTION;
D O I
10.1177/01617346221085184
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Fast and efficient imaging techniques are important for real-time ultrasound imaging. The delay and sum (DAS) beamformer is the most widely-used strategy in focused ultrasound imaging (FUI) modality. However, calculating the time delays and coherently summing the amplitude response in DAS is computationally expensive and generally require a high-performance processor to realize real-time processing. In this study, an efficient spectrum beamformer, namely full-matrix capture (FMC)-stolt, is proposed in FUI system with a linear phased array. The imaging performance of FMC-stolt was validated with the point-scatter simulation and in vitro point and cyst phantoms, and then compared with that of five beamformers, that is, Multiline acquisition (MLA), retrospective transmit beamforming (RTB) in the FUI modality, as well as DAS, Garcia's frequency-wavenumber (f-k), Lu's f-k in the coherent plane wave compounding imaging (CPWCI) modality, under specific conditions. We show that the imaging performance of FMC-stolt is better than MLA-DAS in non-transmit-focal regions, and comparable with RTB-DAS at all imaging depths. FMC-stolt also shows better discontinuity alleviation than MLA and RTB. In addition, FMC-stolt has similar imaging characteristics (e.g., off-axis resolution, computational cost) as the f-k beamformers. The computational complexity and actual computational time indicate that FMC-stolt is comparable to Garcia's f-k, Lu's f-k, and faster than RTB and CPWCI-DAS if the transmitting numbers are close for FUI and CPWCI. The study demonstrates that the proposed FMC-stolt could achieve good reconstruction speed while preserving high-quality images and thus provide a choice for software beamforming for conventional B-mode ultrasound imaging, especially for hand-held devices with limited performance processors.
引用
收藏
页码:59 / 76
页数:18
相关论文
共 50 条
  • [21] A system for analyzing intraoperative B-Mode ultrasound scans of the liver
    Nowatschin, Stephan
    Markert, Mathias
    Weber, Stefan
    Lueth, Tim C.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 1346 - 1349
  • [22] A computerised quality control testing system for B-mode ultrasound
    Gibson, NM
    Dudley, NJ
    Griffith, K
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (12): : 1697 - 1711
  • [23] ULTRASOUND B-MODE IMAGING FOR ARTERIAL-WALL THICKNESS MEASUREMENT
    PIGNOLI, P
    ATHEROSCLEROSIS REVIEWS, 1984, 12 : 177 - 184
  • [24] A New Nonlinear Compounding Technique for Ultrasound B-mode Medical Imaging
    Moubark, Asraf Mohamed
    Nie, Luzhen
    Cowell, David M. J.
    Md, Sawal Hamid
    Freear, Steven
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 1021 - 1024
  • [25] The use of ultrasound contrast to quantify kidney perfusion with B-mode imaging
    Mattrey, RF
    Peterson, TM
    Baker, KG
    Dieranieh, L
    Lee, YZ
    Steinbach, GC
    RADIOLOGY, 1998, 209P : 461 - 462
  • [26] PDMS Composites with Photostable NIR Dyes for B-Mode Ultrasound Imaging
    Thompson, India Lewis
    Mathews, Sunish
    Zhang, Edward
    Beard, Paul
    Desjardins, Adrien
    Colchester, Richard
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [27] Effect of B-mode ultrasound imaging in the assessment of carotid artery stenosis
    Hingorani, A
    Ascher, E
    Markevich, N
    Schutzer, R
    Kallakuri, S
    Hou, A
    Salles-Cunha, S
    CIRCULATION, 2003, 107 (19) : E176 - E176
  • [28] An Ideal Observer Approach to Mechanical Limits in B-Mode Ultrasound Imaging
    Abbey, Craig K.
    Nguyen, Nghia Q.
    O'Brien, William D., Jr.
    Insana, Michael F.
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 2306 - 2309
  • [29] TRANS-STENT B-MODE ULTRASOUND AND PASSIVE CAVITATION IMAGING
    Haworth, Kevin J.
    Raymond, Jason L.
    Radhakrishnan, Kirthi
    Moody, Melanie R.
    Huang, Shao-Ling
    Peng, Tao
    Shekhar, Himanshu
    Klegerman, Melvin E.
    Kim, Hyunggun
    McPherson, David D.
    Holland, Christy K.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (02): : 518 - 527
  • [30] The value of contrast-enhanced ultrasound fusion imaging in percutaneous liver biopsy for liver lesions invisible on conventional B-mode ultrasound
    He, Yuhong
    Gong, Li
    Wu, Jie
    Wen, Baojie
    Kong, Wentao
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2025, 15 (02) : 1528 - 1542