Evaluation of blood pressure measured by tail-cuff methods (without heating) in spontaneously hypertensive rats

被引:115
|
作者
Kubota, Yoko
Umegaki, Keizo
Kagota, Satomi
Tanaka, Naoka
Nakamura, Kazuki
Kunitomo, Masaru
Shinozuka, Kazumasa [1 ]
机构
[1] Mukogawa Womens Univ, Sch Pharmaceut Sci, Dept Pharmacol, Nishinomiya, Hyogo 6638179, Japan
[2] Natl Inst Hlth & Nutr, Shinjuku Ku, Tokyo 1628636, Japan
[3] Kyushu Univ Hlth & Welf, Sch Pharmaceut Sci, Dept Pharmacol, Nobeoka 8828508, Japan
关键词
blood pressure; spontaneously hypertensive rat; tail-cuff method; telemetry method;
D O I
10.1248/bpb.29.1756
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Conventional noninvasive blood pressure in conscious rats or mice are typically measured using the tail-cuff method after heating the animal. The goal of this study was to assess the validity of a novel tail-cuff method without animal heating when compared with the conventional heating tail-cuff method (unanesthetized rats with heating), telemetry method (unanesthetized restrained rats without heating), or carotid arterial catheter method (anesthetized rats, carotid arterial cannulation). The blood pressure and heart rate of spontaneously hypertensive rats were measured at 13:00-17:00 h for all experiments. Experiments demonstrated similar systolic blood pressure measurements when comparing the unheated-animal tail-cuff method and the telemetry method. Further, values obtained by both methods were lower than those obtained by the heated-animal tail-cuff method. Systolic blood pressure measurements obtained through carotid arterial cannulation were lower than those obtained by any other method. The heart rate was highest using the unheated-animal tail-cuff method when compared with the other methods. These data suggest that the novel unheated-animal tail-cuff method is a sensitive and accurate approach for the noninvasive measurement of blood pressure in conscious rats.
引用
收藏
页码:1756 / 1758
页数:3
相关论文
共 50 条
  • [21] EVALUATION OF A NEW TAIL-CUFF METHOD FOR BLOOD-PRESSURE MEASUREMENT IN RATS WITH SPECIAL REFERENCE TO THE EFFECTS OF AMBIENT-TEMPERATURE
    KUWAHARA, M
    SUGANO, S
    YAYOU, K
    TSUBONE, H
    KOBAYASHI, H
    EXPERIMENTAL ANIMALS, 1991, 40 (03) : 331 - 336
  • [22] COMPARISON OF A TAIL-CUFF METHOD OF MEASURING RAT BLOOD-PRESSURE WITH DIRECT ARTERIAL RECORDINGS OF BLOOD-PRESSURE IN CONSCIOUS RATS
    ANDREWS, DI
    JONES, DR
    PROCEEDINGS OF THE UNIVERSITY OF OTAGO MEDICAL SCHOOL, 1978, 56 (01): : 3 - 4
  • [23] α-lactorphin lowers blood pressure measured by radiotelemetry in normotensive and spontaneously hypertensive rats
    Nurminen, ML
    Sipola, M
    Kaarto, H
    Pihlanto-Leppälä, A
    Piilola, K
    Korpela, R
    Tossavainen, O
    Korhonen, H
    Vapaatalo, H
    LIFE SCIENCES, 2000, 66 (16) : 1535 - 1543
  • [24] An improved technique for tail-cuff blood pressure measurements with dark-tailed mice
    Hagaman, JR
    John, S
    Xu, LQ
    Smithies, O
    Maeda, N
    CONTEMPORARY TOPICS IN LABORATORY ANIMAL SCIENCE, 2005, 44 (05): : 43 - 46
  • [25] Does Tail-Cuff Plethysmography Provide a Reliable Estimate of Central Blood Pressure in Mice?
    Fink, Gregory D.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2017, 6 (06):
  • [26] TAIL-CUFF METHOD FOR MEASURING SYSTOLIC BLOOD-PRESSURE IN SQUIRREL-MONKEYS
    SIA, JB
    SCHWAM, E
    MANN, W
    SEPINWALL, J
    PHYSIOLOGY & BEHAVIOR, 1975, 14 (05) : 659 - 662
  • [27] MEASUREMENT OF MEAN ARTERIAL-PRESSURE IN RATS BY A TAIL-CUFF METHOD WITH SENSITIVE PHOTOELECTRIC SENSORS
    SAKAMAKI, T
    TAJIMA, Y
    ICHIKAWA, S
    MURATA, K
    EXPERIMENTAL ANIMALS, 1987, 36 (04) : 409 - 414
  • [28] Nicorandil Ameliorated Hypertensive Renal Injury without Lowering Blood Pressure in Spontaneously Hypertensive Rats
    Serizawa, Kenichi
    Yogo, Kenji
    Tashiro, Yoshihito
    Koike, Nobuo
    Aizawa, Ken
    Hirata, Michinori
    Ishizuka, Nobuhiko
    PHARMACOLOGY, 2013, 91 (1-2) : 92 - 103
  • [29] A rat-friendly modification of the non-invasive tail-cuff to record blood pressure
    Liptak, Boris
    Kaprinay, Barbara
    Gasparova, Zdenka
    LAB ANIMAL, 2017, 46 (06) : 251 - 253
  • [30] DIASTOLIC AND SYSTOLIC BLOOD-PRESSURE MEASUREMENTS IN MONKEYS DETERMINED BY A NONINVASIVE TAIL-CUFF TECHNIQUE
    WIESTER, MJ
    ILTIS, R
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1976, 87 (02): : 354 - 361