Evaluation of blood pressure measured by tail-cuff methods (without heating) in spontaneously hypertensive rats

被引:114
|
作者
Kubota, Yoko
Umegaki, Keizo
Kagota, Satomi
Tanaka, Naoka
Nakamura, Kazuki
Kunitomo, Masaru
Shinozuka, Kazumasa [1 ]
机构
[1] Mukogawa Womens Univ, Sch Pharmaceut Sci, Dept Pharmacol, Nishinomiya, Hyogo 6638179, Japan
[2] Natl Inst Hlth & Nutr, Shinjuku Ku, Tokyo 1628636, Japan
[3] Kyushu Univ Hlth & Welf, Sch Pharmaceut Sci, Dept Pharmacol, Nobeoka 8828508, Japan
关键词
blood pressure; spontaneously hypertensive rat; tail-cuff method; telemetry method;
D O I
10.1248/bpb.29.1756
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Conventional noninvasive blood pressure in conscious rats or mice are typically measured using the tail-cuff method after heating the animal. The goal of this study was to assess the validity of a novel tail-cuff method without animal heating when compared with the conventional heating tail-cuff method (unanesthetized rats with heating), telemetry method (unanesthetized restrained rats without heating), or carotid arterial catheter method (anesthetized rats, carotid arterial cannulation). The blood pressure and heart rate of spontaneously hypertensive rats were measured at 13:00-17:00 h for all experiments. Experiments demonstrated similar systolic blood pressure measurements when comparing the unheated-animal tail-cuff method and the telemetry method. Further, values obtained by both methods were lower than those obtained by the heated-animal tail-cuff method. Systolic blood pressure measurements obtained through carotid arterial cannulation were lower than those obtained by any other method. The heart rate was highest using the unheated-animal tail-cuff method when compared with the other methods. These data suggest that the novel unheated-animal tail-cuff method is a sensitive and accurate approach for the noninvasive measurement of blood pressure in conscious rats.
引用
收藏
页码:1756 / 1758
页数:3
相关论文
共 50 条
  • [1] Comparison of simultaneous measurements of blood pressure by tail-cuff and carotid arterial methods in conscious spontaneously hypertensive and Wistar-Kyoto rats
    Ibrahim, J
    Berk, BC
    Hughes, AD
    CLINICAL AND EXPERIMENTAL HYPERTENSION, 2006, 28 (01) : 57 - 72
  • [2] TAIL-CUFF BLOOD-PRESSURE MEASUREMENT WITHOUT EXTERNAL PREHEATING IN AWAKE RATS
    BUNAG, RD
    BUTTERFIELD, J
    HYPERTENSION, 1982, 4 (06) : 898 - 903
  • [3] INTRAARTERIAL PRESSURE ALTERATIONS DURING TAIL-CUFF BLOOD-PRESSURE MEASUREMENTS IN NORMOTENSIVE AND HYPERTENSIVE RATS
    FERRARI, AU
    DAFFONCHIO, A
    ALBERGATI, F
    BERTOLI, P
    MANCIA, G
    JOURNAL OF HYPERTENSION, 1990, 8 (10) : 909 - 911
  • [4] VALIDITY OF AN INDIRECT TAIL-CUFF METHOD FOR DETERMINING SYSTOLIC ARTERIAL PRESSURE IN UNANESTHETIZED NORMOTENSIVE AND SPONTANEOUSLY HYPERTENSIVE RATS
    PFEFFER, JM
    PFEFFER, MA
    FROHLICH, ED
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1971, 78 (06): : 957 - &
  • [5] Tail-Cuff Versus Radiotelemetry to Measure Blood Pressure in Mice and Rats
    Harrison, D. G.
    Bader, M.
    Lerman, L. O.
    Fink, G.
    Karumanchi, S. A.
    Reckelhoff, J. F.
    Sequeira-Lopez, M. L. S.
    Touyz, R. M.
    HYPERTENSION, 2024, 81 (01) : 3 - 5
  • [6] LIMITATIONS OF THE TAIL-CUFF METHOD FOR MEASURING BLOOD-PRESSURE IN RATS
    FERRARI, AU
    DAFFONCHIO, A
    ALBERGATI, F
    MANCIA, G
    JOURNAL OF HYPERTENSION, 1986, 4 : S179 - S181
  • [7] Blood pressure measurement in mice: tail-cuff or telemetry?
    Drueke, Tilman B.
    Devuyst, Olivier
    KIDNEY INTERNATIONAL, 2019, 96 (01) : 36 - 36
  • [8] PRESSOR EFFECTS OF TAIL-CUFF METHOD IN AWAKE NORMOTENSIVE AND HYPERTENSIVE RATS
    BUNAG, RD
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1971, 78 (04): : 675 - &
  • [9] LIMITATIONS OF THE TAIL-CUFF METHOD (TC) FOR MEASURING BLOOD-PRESSURE (BP) IN RATS
    FERRARI, AU
    DAFFONCHIO, A
    ALBERGATI, F
    MANCIA, G
    JOURNAL OF HYPERTENSION, 1986, 4 : S574 - S574
  • [10] Rodent Thermoregulation: Considerations for Tail-Cuff Blood Pressure Measurements
    Bigiarelli, Krista J.
    JOURNAL OF THE AMERICAN ASSOCIATION FOR LABORATORY ANIMAL SCIENCE, 2022, 61 (05): : 406 - 411