Accuracy of 2 impression techniques for ITI implants

被引:1
|
作者
Akça, K [1 ]
Çehreli, MC [1 ]
机构
[1] Hacettepe Univ, Fac Dent, Dept Prosthodont, Ankara, Turkey
关键词
dental implants; impression materials; impression techniques;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to compare the accuracy of casts produced by 2 impression techniques and elastomeric impression materials commonly used for the fabrication of implant-supported fixed prostheses. Materials and Methods: A master model with 4 synOcta ITI implants placed unilaterally in place of the mandibular right central incisor, canine, first premolar, and first molar was constructed. Implant-level impressions were made by direct and indirect techniques. In the direct technique, synOcta impression caps with integral guide screws were used to transfer the implants using a custom-made acrylic resin tray and a polyether impression material (the PE direct technique). In the indirect technique, synOcta plastic positioning cylinders with impression caps were used to transfer the implants with either a custom-made acrylic resin tray and polyether impression material (the PE indirect technique) or with a stock tray with a vinylpolysiloxane impression material (the VPS indirect technique). After impression making, all casts (n = 21) were poured in type IV dental stone. Linear changes in -x or -y direction and numeric and descriptive angular changes between the implants were quantified using a coordinate measuring machine. Results: Seven of 12 distance measurements (6 for -x direction, 6 for -y direction) showed differences between groups (P < .05). Of these, 5 were associated with the PE direct versus PE indirect and PE indirect versus VPS indirect, and 3 were associated with PE direct versus VPS indirect. Two implants also showed angular changes but only for the PE indirect technique versus the VPS indirect technique (P < .05). Conclusion: The snap-on VPS indirect impression technique using a stock tray, which has the advantages of being clinically convenient and eliminating repositioning after removal of the impression, resulted in dimensional accuracy similar to that achieved with the PE direct technique.
引用
收藏
页码:517 / 523
页数:7
相关论文
共 50 条
  • [21] Accuracy of Digital Dental Implants Impression Taking with Intraoral Scanners Compared with Conventional Impression Techniques: A Systematic Review of In Vitro Studies
    Albanchez-Gonzalez, Maria Isabel
    Brinkmann, Jorge Cortes-Breton
    Pelaez-Rico, Jesus
    Lopez-Suarez, Carlos
    Rodriguez-Alonso, Veronica
    Suarez-Garcia, Maria Jesus
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (04)
  • [22] Comparative Analysis of 4 Impression Techniques for Implants
    Cabral, Leonardo Moreira
    Guedes, Carlos Gramani
    IMPLANT DENTISTRY, 2007, 16 (02) : 187 - 194
  • [23] ACCURACY OF IMPRESSION TECHNIQUES IN IMPLANT DENTISTRY
    Alrumi, Bader Abdullah
    al Yami, Ibrahim Mohammed
    Alghamdi, Randah Abdulrhman
    Aldajani, Ali Mohammed
    Alhelaly, Hussein Mohammed
    Mohammed, Abdulrahman Thabet
    Abotaleb, Mohannd Talebalrahman
    Aljuaid, Mohammed Mbearak
    Alotaibi, Jamal Mousa
    Alelyani, Mohammed Dakhil
    INDO AMERICAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2019, 6 (01): : 1396 - 1402
  • [24] Accuracy of impressions with different impression materials in angulated implants
    Reddy, S.
    Prasad, K.
    Vakil, H.
    Jain, A.
    Chowdhary, R.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2013, 16 (03) : 279 - 284
  • [25] Prosthetic transfer impression accuracy evaluation for osseointegrated implants
    Assuncao, Wirley Goncalves
    Tabata, Lucas Fernando
    Cardoso, Alessandra
    Rocha, Eduardo Passos
    Gomes, Erica Alves
    IMPLANT DENTISTRY, 2008, 17 (03) : 248 - 252
  • [26] Accuracy of digital impression in dental implants: A literature review
    Kulivand, Sudabe
    Moslemion, Maryam
    INTERNATIONAL JOURNAL OF ADVANCED BIOTECHNOLOGY AND RESEARCH, 2016, 7 (04): : 2093 - 2100
  • [27] Accuracy of Impression Techniques for Impants. Part 2-Comparison of Splinting Techniques
    Gennari Filho, Humberto
    Quinelli Mazaro, Jose Vitor
    Vedovatto, Eduardo
    Assuncao, Wirley Goncalves
    dos Santos, Paulo Henrique
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2009, 18 (02): : 172 - 176
  • [28] Accuracy of Three Implant Impression Techniques with Different Impression Materials and Stones
    Chang, Won-Gun
    Vahidi, Farhad
    Bae, Kwang-Hak
    Lim, Bum-Soon
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2012, 25 (01) : 44 - 47
  • [29] EVALUATION OF 3 IMPRESSION TECHNIQUES FOR OSSEOINTEGRATED ORAL IMPLANTS
    INTURREGUI, JA
    AQUILINO, SA
    RYTHER, JS
    LUND, PS
    SOUTHARD, TE
    JOURNAL OF PROSTHETIC DENTISTRY, 1993, 69 (05): : 503 - 509
  • [30] Influence of materials and impression techniques in asseointegrated implants.
    Kleine, A
    Nóbilo, MAA
    Henriques, GEP
    Mesquita, MF
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B144 - B144