Intrapartum fetal heart rate monitoring

被引:9
|
作者
Boehm, FH [1 ]
机构
[1] Vanderbilt Univ, Ctr Med, B1100 Med Ctr N, Dept Maternal Fetal Med, Nashville, TN 37232 USA
关键词
D O I
10.1016/S0889-8545(05)70103-0
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Intrapartum fetal heart rate monitoring is commonly used to evaluate fetal status in labor, despite a lack of convincing randomized studies to support its use. The National Institutes of Health have helped, standardize fetal heart rate monitoring terminology with their 1997 task force report, which will aid clinicians and scientists in their goal of providing quality care and research. The American College of Obstetricians and Gynecologists has recommended the term nonreassuring fetal status for electronic fetal monitor patterns that are not normal; however, Vanderbilt continues to use the terms fetal stress and fetal distress, using specific criteria for each. The approximately 30% of fetal heart rate tracings labeled as fetal stress (or nonreassuring fetal status) can be evaluated further by the use of fetal pulse oximetry, a new technology currently under evaluation in this country.
引用
收藏
页码:623 / +
页数:19
相关论文
共 50 条
  • [31] Fetal heart rate and maternal heart rate confusion during intrapartum monitoring: comparison of transabdominal fetal ECG and Doppler telemetry
    Signaroldi, Maria
    Mastroianni, Cristina
    Rosti, Eleonora
    Loi, Giorgia
    Di Francesco, Stefania
    Ferrazzi, Enrico
    Stampalija, Tamara
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2011, 204 : S261 - S262
  • [32] INTRAPARTUM FETAL HEART-RATE MONITORING .3. ASSOCIATION OF MECONIUM WITH ABNORMAL FETAL HEART-RATE PATTERNS
    KREBS, HB
    PETRES, RE
    DUNN, LJ
    JORDAAN, HVF
    SEGRETI, A
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1980, 137 (08) : 936 - 943
  • [33] Importance of electronic monitoring of intrapartum fetal heart rate as a predictor of neonatal outcomes
    Fernanda Nozar, Maria
    Fiol, Veronica
    Martinez, Alma
    Enrique Pons, Jose
    Alonso, Justo
    Briozzo, Leonel
    REVISTA MEDICA DEL URUGUAY, 2008, 24 (02): : 94 - 101
  • [34] Intrapartum electronic fetal heart rate monitoring and the prevention of perinatal brain injury
    Graham, Ernest M.
    Petersen, Scott M.
    Christo, Dana K.
    Fox, Harold E.
    OBSTETRICS AND GYNECOLOGY, 2006, 108 (03): : 656 - 666
  • [35] THE CLINICAL-SIGNIFICANCE OF ACCELERATIONS IN INTRAPARTUM FETAL HEART-RATE MONITORING
    RICHTER, R
    HOHL, M
    LUSCHER, KP
    STUCKI, D
    ZEITSCHRIFT FUR GEBURTSHILFE UND PERINATOLOGIE, 1980, 184 (03): : 195 - 199
  • [36] INTRAPARTUM FETAL HEART-RATE ASSESSMENT - MONITORING BY AUSCULTATION OR ELECTRONIC MEANS
    MORRISON, JC
    CHEZ, BF
    DAVIS, ID
    MARTIN, RW
    ROBERTS, WE
    MARTIN, JN
    FLOYD, RC
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1993, 168 (01) : 63 - 66
  • [37] Risk Management in Intrapartum Fetal Monitoring Accidental Recording of the Maternal Heart Rate
    Hanson, Lisa
    JOURNAL OF PERINATAL & NEONATAL NURSING, 2010, 24 (01) : 7 - 9
  • [38] Reliability and agreement in intrapartum fetal heart rate monitoring interpretation: A systematic review
    Engelhart, Christina Hernandez
    Brurberg, Kjetil Gundro
    Aanstad, Kristin Jerve
    Pay, Aase Serine Devold
    Kaasen, Anne
    Blix, Ellen
    Vanbelle, Sophie
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2023, 102 (08) : 970 - 985
  • [39] Utility of Intrapartum Fetal Heart Rate Monitoring in a Contemporary Labor and Delivery Unit
    Taylor, Rachel
    Burk, Camden
    Sugiyama, Nathaniel
    Friedman, Perry
    Ogunyemi, Dotun
    OBSTETRICS AND GYNECOLOGY, 2017, 129 : 174S - 174S
  • [40] Bayesian interpretation of trials: the example of intrapartum electronic fetal heart rate monitoring
    Hornbuckle, J
    Vail, A
    Abrams, KR
    Thornton, JG
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2000, 107 (01): : 3 - 10