A novel, molecularly imprinted polymer sensor made using an oligomeric methyl silsesquioxane-TiO2 composite sol on a glassy carbon electrode for the detection of procainamide hydrochloride

被引:17
|
作者
Wang, Kai [1 ]
Guan, Xiwen [1 ]
Chai, Shigan [1 ]
Zou, Qichao [1 ]
Zhang, Xiuhua [1 ]
Zhang, Jinzhi [1 ]
机构
[1] Hubei Univ, Coll Chem & Chem Engn, Hubei Collaborat Innovat Ctr Adv Organ Chem Mat, Key Lab Synth & Applicat Organ Funct Mol,Minist E, Wuhan 430062, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Procainamide hydrochloride; MIP; O-MSSQ; TiO2; Composite sol; PERFORMANCE LIQUID-CHROMATOGRAPHY; INDIUM TIN OXIDE; ELECTROCHEMICAL SENSOR; N-ACETYLPROCAINAMIDE; SELECTIVE DETECTION; CHEMICAL-MODIFICATION; ULTRATHIN FILMS; TIO2; GEL; LAYER;
D O I
10.1016/j.bios.2014.08.053
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this study, we designed a novel molecularly imprinted polymer (MIP), oligomeric methyl silsesquioxane (O-MSSQ)-TiO2 composite sal, which was made using a sol-gel reaction. This polymer has structural rigidity and high surface area of O-MSSQ as well as high bio-compatibility and relatively good conductivity of the TiO2. Next, a sensitive and selective imprinted electrochemical sensor was successfully constructed for the direct detection of procainamide hydrochloride by molecularly imprinting a film onto the surface of a glassy carbon electrode. Adding TiO2 resulted in a noticeable enhancement in the sensitivity of the MIP sensor. The performance of the O-MSSQ-TiO2 film was discussed, and the optimal conditions for detection were determined. The oxidative peak current increased linearly with the concentration of procainamide hydrochloride in the range of 4.00 x 10(-9)-4.97 x 10(-5) M using differential pulse voltammetry, and the detection limit was 1.30 x 10(-9) M with S/N=3. Furthermore, the sensor was applied to determine the procainamide hydrochloride content in a human blood serum sample. The recoveries of the sensors varied from 96.77% to 101.35%, indicating that the prepared sensor might be promising for the determination of procainamide hydrochloride in clinical tests. Moreover, the imprinted electrochemical sensor was used to selectively detect procainarnide hydrochloride. The analytical application was conducted successfully and yielded accurate and precise results. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:94 / 101
页数:8
相关论文
共 34 条
  • [31] Novel electrochemical sensor based on rGO@TiO2 composite material and ion-imprinted polymer modification for highly selective detection of cadmium ions in real samples
    Zhang, Yi
    Liu, Yanmeng
    Xu, Wanzhen
    Huang, Weihong
    Chen, Ting
    Ding, Hua
    Wang, Baozhi
    Yang, Wenming
    IONICS, 2024, 30 (04) : 2345 - 2355
  • [32] Novel dual-sensor for creatinine and 8-hydroxy-2′-deoxyguanosine using carbon-paste electrode modified with molecularly imprinted polymers and multiple-pulse amperometry
    Nontawong, Nongyao
    Amatatongchai, Maliwan
    Jarujamrus, Purim
    Nacapricha, Duangjai
    Lieberzeit, Peter A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 334
  • [33] Electrochemical Detection of Paracetamol in Real Samples Using Sensor Based on a Glassy Carbon Electrode Modified with Chitosan@SiO2-APTES Composite: Synthesis, Characterization and Analytical Applications
    Dhaffouli, Afef
    Ali, Emna
    Moussaoui, Younes
    Holzinger, Michael
    Salazar-Carballo, Pedro A.
    Carinelli, Soledad
    Barhoumi, Houcine
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2025, 172 (01)
  • [34] Novel Chemoresistive Sensor for Sensitive Detection of Pb2+ Ions Using an Interdigital Gold Electrode Fabricated with a Reduced Graphene Oxide-Based Ion-Imprinted Polymer
    Letsoalo, Mokgehle R.
    Ambushe, Abayneh A.
    Mamo, Messai A.
    ACS OMEGA, 2021, 6 (47): : 31528 - 31538