A novel, molecularly imprinted polymer sensor made using an oligomeric methyl silsesquioxane-TiO2 composite sol on a glassy carbon electrode for the detection of procainamide hydrochloride

被引:17
|
作者
Wang, Kai [1 ]
Guan, Xiwen [1 ]
Chai, Shigan [1 ]
Zou, Qichao [1 ]
Zhang, Xiuhua [1 ]
Zhang, Jinzhi [1 ]
机构
[1] Hubei Univ, Coll Chem & Chem Engn, Hubei Collaborat Innovat Ctr Adv Organ Chem Mat, Key Lab Synth & Applicat Organ Funct Mol,Minist E, Wuhan 430062, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Procainamide hydrochloride; MIP; O-MSSQ; TiO2; Composite sol; PERFORMANCE LIQUID-CHROMATOGRAPHY; INDIUM TIN OXIDE; ELECTROCHEMICAL SENSOR; N-ACETYLPROCAINAMIDE; SELECTIVE DETECTION; CHEMICAL-MODIFICATION; ULTRATHIN FILMS; TIO2; GEL; LAYER;
D O I
10.1016/j.bios.2014.08.053
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this study, we designed a novel molecularly imprinted polymer (MIP), oligomeric methyl silsesquioxane (O-MSSQ)-TiO2 composite sal, which was made using a sol-gel reaction. This polymer has structural rigidity and high surface area of O-MSSQ as well as high bio-compatibility and relatively good conductivity of the TiO2. Next, a sensitive and selective imprinted electrochemical sensor was successfully constructed for the direct detection of procainamide hydrochloride by molecularly imprinting a film onto the surface of a glassy carbon electrode. Adding TiO2 resulted in a noticeable enhancement in the sensitivity of the MIP sensor. The performance of the O-MSSQ-TiO2 film was discussed, and the optimal conditions for detection were determined. The oxidative peak current increased linearly with the concentration of procainamide hydrochloride in the range of 4.00 x 10(-9)-4.97 x 10(-5) M using differential pulse voltammetry, and the detection limit was 1.30 x 10(-9) M with S/N=3. Furthermore, the sensor was applied to determine the procainamide hydrochloride content in a human blood serum sample. The recoveries of the sensors varied from 96.77% to 101.35%, indicating that the prepared sensor might be promising for the determination of procainamide hydrochloride in clinical tests. Moreover, the imprinted electrochemical sensor was used to selectively detect procainarnide hydrochloride. The analytical application was conducted successfully and yielded accurate and precise results. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:94 / 101
页数:8
相关论文
共 34 条
  • [1] Electrochemical Sensor for Detection of Trichlorfon Based on Molecularly Imprinted Sol–Gel Films Modified Glassy Carbon Electrode
    Weiqiang Gao
    Fuwei Wan
    Wei Ni
    Shaowei Wang
    Meng Zhang
    Jinghua Yu
    Journal of Inorganic and Organometallic Polymers and Materials, 2012, 22 : 37 - 41
  • [2] Molecularly Imprinted Polymer Based Sensor for Measuring of Levodopa: Evaluation as a Modifier for Glassy Carbon Electrode in Electrochemically Detection
    Siavashi, Reza
    Beitollahi, Hadi
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2023, 59 (01) : 70 - 78
  • [4] Electrochemical Sensor for Detection of Trichlorfon Based on Molecularly Imprinted Sol-Gel Films Modified Glassy Carbon Electrode
    Gao, Weiqiang
    Wan, Fuwei
    Ni, Wei
    Wang, Shaowei
    Zhang, Meng
    Yu, Jinghua
    JOURNAL OF INORGANIC AND ORGANOMETALLIC POLYMERS AND MATERIALS, 2012, 22 (01) : 37 - 41
  • [5] Voltammetric lidocaine sensor by using a glassy carbon electrode modified with porous carbon prepared from a MOF, and with a molecularly imprinted polymer
    Junjie Zhang
    Jiang Liu
    Yang Zhang
    Feng Yu
    Fu Wang
    Zhengchun Peng
    Yingchun Li
    Microchimica Acta, 2018, 185
  • [6] Voltammetric lidocaine sensor by using a glassy carbon electrode modified with porous carbon prepared from a MOF, and with a molecularly imprinted polymer
    Zhang, Junjie
    Liu, Jiang
    Zhang, Yang
    Yu, Feng
    Wang, Fu
    Peng, Zhengchun
    Li, Yingchun
    MICROCHIMICA ACTA, 2018, 185 (01)
  • [7] Cefixime detection by a novel electrochemical sensor based on glassy carbon electrode modified with surface imprinted polymer/multiwall carbon nanotubes
    Karimian, N.
    Gholivand, M. B.
    Malekzadeh, Gh.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 771 : 64 - 72
  • [8] Electrochemical Detection of Gallic Acid in Green Tea Using Molecularly Imprinted Polymers on TiO2@CNTs Nanocomposite Modified Glassy Carbon Electrode
    Qin, Fengxian
    Hu, Tiejun
    You, Lixin
    Chen, Wei
    Jia, Dongshu
    Hu, Nannan
    Qi, Weihua
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (04):
  • [9] An electrochemical sensor based on the molecularly imprinted polymer/ single walled carbon nanotube-modified glassy carbon electrode for detection of zineb fungicide in food samples
    Mahmodnezhad, Shokofeh
    Roushani, Mahmoud
    Karazan, Zahra Mirzaei
    FOOD CONTROL, 2025, 168
  • [10] A novel sensor made of Antimony Doped Tin Oxide-silica composite sol on a glassy carbon electrode modified by single-walled carbon nanotubes for detection of norepinephrine
    Wang, Zhao
    Wang, Kai
    Zhao, Lu
    Chai, Shigan
    Zhang, Jinzhi
    Zhang, Xiuhua
    Zou, Qichao
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 80 : 180 - 186