Free-breathing dynamic liver examination using a radial 3D T1-weighted gradient echo sequence with moderate undersampling for patients with limited breath-holding capacity

被引:20
|
作者
Kaltenbach, Benjamin [1 ]
Roman, Andrei [1 ]
Polkowski, Christoph [1 ]
Gruber-Rouh, Tatjana [1 ]
Bauer, Ralf W. [1 ,2 ]
Hammerstingl, Renate [1 ]
Vogl, Thomas J. [1 ]
Zangos, Stephan [1 ]
机构
[1] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Frankfurt, Germany
[2] Kantonsspital, Div Radiol & Nucl Med, St Gallen, Switzerland
关键词
Dynamic liver MRI; Respiratory artifacts; Radial data sampling; Undersampled radial acquisition; MRI; RECONSTRUCTION; ARTIFACTS; QUALITY;
D O I
10.1016/j.ejrad.2016.11.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare free-breathing radial VIBE with moderate undersampling (us-radial-VIBE) with a standard breathhold TI-weighted volumetric interpolated sequence (3D GRE VIBE) in patients unable to suspend respiration during dynamic liver examination. Material and methods: 23 consecutive patients underwent dynamic liver MR examination using the free breathing us-radial-VIBE sequence as part of their oncologic follow-up. All patients were eligible for the free-breathing protocol due to severe respiratory artifacts at the planning or precontrast sequences. The us-radial-VIBE acquisitions were compared to the patients1 last staging liver MRI including a standard breathhold 3D GRE VIBE. For an objective image evaluation, signal intensity (SI), image noise (IN), signal-to-noise ratio (SNR) and contrast-enhancement ratio (CER) were compared. Representative image quality parameters, including typical artifacts were independently, retrospectively and blindly scored by four readers. Results: Us-radial-VIBE had significant lower SNR (p < 0.0001) and higher IN (p < 0.0001), whereas SI did not differ (p = 0.62). Temporal resolution assessed with CER in the arterial phase showed higher values for us-radial-VIBE (p = 0.028). Subjective image quality parameters received generally slightly higher scores for 3D GRE VIBE. In a smaller subgroup comprising patients with severe respiratory artifacts also at reference breathhold 3D GRE VIBE examination, us-radial-VIBE showed significantly higher image quality scores. Furthermore, there were generally more severe respiratory artifacts in 3D GRE VIBE, whereas streaking was characteristic in almost all us-radial-VIBE acquisitions but did not affect diagnostic validity. Conclusion: Free-breathing dynamic liver imaging using us-radial-VIBE delivers accurate temporal resolution, low motion artifact susceptibility and good image quality and represents a promising alternative in patients unable to suspend respiration. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:26 / 32
页数:7
相关论文
共 50 条
  • [31] Evaluation of the orbit using contrast-enhanced radial 3D fat-suppressed T1 weighted gradient echo (Radial-VIBE) sequence
    Bangiyev, Lev
    Raz, Eytan
    Block, Tobias K.
    Hagiwara, Mari
    Wu, Xin
    Yu, Eugene
    Fatterpekar, Girish M.
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1054):
  • [32] Advantages of a T1-Weighted Gradient-Recalled Echo (GRE) Sequence With a Radial 3D Sampling Approach Versus 2D Turbo Spin-Echo and Cartesian 3D GRE Sequences in Head and Neck MRI
    Fahlenkamp, Ute Lina
    Siepmann, Stefan
    Fehrenbach, Uli
    Thieme, Nadine
    Doellinger, Felix
    Hamm, Bernd
    Denecke, Timm
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 214 (04) : 747 - 752
  • [33] T1-Weighted 3D Dynamic Contrast-Enhanced MRI of the Breast Using a Dual-Echo Dixon Technique at 3 T
    Dogan, Basak E.
    Ma, Jingfei
    Hwang, Ken
    Liu, Ping
    Yang, Wei Tse
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (04) : 842 - 851
  • [34] B1 Mapping of Short T2* Spins Using a 3D Radial Gradient Echo Sequence
    Kobayashi, Naoharu
    Garwood, Michael
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (05) : 1689 - 1699
  • [35] A comparison of a T1 weighted 3D gradient-echo sequence with three different parallel imaging reduction factors, breath hold and free breathing, using a32 channel coil at 1.5T. A preliminary study
    Heredia, V.
    Dale, B.
    de Campos, R. Op
    Ramalho, M.
    Burke, L. B.
    Sams, C.
    de Toni, M.
    Semelka, R. C.
    RADIOLOGIA, 2014, 56 (06): : 533 - 540
  • [36] Detection of structural lesions of the sacroiliac joints in patients with spondyloarthritis: A comparison of T1-weighted 3D spoiled gradient echo MRI and MRI-based synthetic CT versus T1-weighted turbo spin echo MRI
    Krabbe, Simon
    Moller, Jakob M.
    Hadsbjerg, Anna E. F.
    Ewald, Anne
    Hangaard, Stine
    Pedersen, Susanne J.
    Ostergaard, Mikkel
    SKELETAL RADIOLOGY, 2024, 53 (11) : 2459 - 2468
  • [37] Hepatic Iron Quantification Using a Free-Breathing 3D Radial Gradient Echo Technique and Validation With a 2D Biopsy-Calibrated R2* Relaxometry Method
    Rohani, Shawyon Chase
    Morin, Cara E.
    Zhong, Xiaodong
    Kannengiesser, Stephan
    Shrestha, Utsav
    Goode, Chris
    Holtrop, Joseph
    Khan, Ayaz
    Loeffler, Ralf B.
    Hankins, Jane S.
    Hillenbrand, Claudia M.
    Tipirneni-Sajja, Aaryani
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 55 (05) : 1407 - 1416
  • [38] Hybrid 3D T1-weighted gradient-echo sequence for fiducial marker detection and tumor delineation via magnetic resonance imaging in liver stereotactic body radiation therapy
    Kato, Yutaka
    Kamomae, Takeshi
    Kumagai, Motoki
    Oie, Yumi
    Noguchi, Yumiko
    Okudaira, Kuniyasu
    Kawamura, Mariko
    Taoka, Toshiaki
    Naganawa, Shinji
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 95 : 9 - 15
  • [39] Editorial for "Hepatic Iron Quantification Using a Free-Breathing 3D Radial Gradient Echo Technique and Validation with a 2D Biopsy-Calibrated R2*Relaxometry Method"
    Lindquist, Diana M.
    Dillman, Jonathan R.
    Tkach, Jean A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 55 (05) : 1417 - 1418
  • [40] Clinical Feasibility of Free-Breathing Dynamic T1-Weighted Imaging With Gadoxetic Acid-Enhanced Liver Magnetic Resonance Imaging Using a Combination of Variable Density Sampling and Compressed Sensing
    Yoon, Jeong Hee
    Yu, Mi Hye
    Chang, Won
    Park, Jin-Young
    Nickel, Marcel Dominik
    Son, Yohan
    Kiefer, Berthold
    Lee, Jeong Min
    INVESTIGATIVE RADIOLOGY, 2017, 52 (10) : 596 - 604