Free-breathing dynamic liver examination using a radial 3D T1-weighted gradient echo sequence with moderate undersampling for patients with limited breath-holding capacity

被引:20
|
作者
Kaltenbach, Benjamin [1 ]
Roman, Andrei [1 ]
Polkowski, Christoph [1 ]
Gruber-Rouh, Tatjana [1 ]
Bauer, Ralf W. [1 ,2 ]
Hammerstingl, Renate [1 ]
Vogl, Thomas J. [1 ]
Zangos, Stephan [1 ]
机构
[1] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Frankfurt, Germany
[2] Kantonsspital, Div Radiol & Nucl Med, St Gallen, Switzerland
关键词
Dynamic liver MRI; Respiratory artifacts; Radial data sampling; Undersampled radial acquisition; MRI; RECONSTRUCTION; ARTIFACTS; QUALITY;
D O I
10.1016/j.ejrad.2016.11.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare free-breathing radial VIBE with moderate undersampling (us-radial-VIBE) with a standard breathhold TI-weighted volumetric interpolated sequence (3D GRE VIBE) in patients unable to suspend respiration during dynamic liver examination. Material and methods: 23 consecutive patients underwent dynamic liver MR examination using the free breathing us-radial-VIBE sequence as part of their oncologic follow-up. All patients were eligible for the free-breathing protocol due to severe respiratory artifacts at the planning or precontrast sequences. The us-radial-VIBE acquisitions were compared to the patients1 last staging liver MRI including a standard breathhold 3D GRE VIBE. For an objective image evaluation, signal intensity (SI), image noise (IN), signal-to-noise ratio (SNR) and contrast-enhancement ratio (CER) were compared. Representative image quality parameters, including typical artifacts were independently, retrospectively and blindly scored by four readers. Results: Us-radial-VIBE had significant lower SNR (p < 0.0001) and higher IN (p < 0.0001), whereas SI did not differ (p = 0.62). Temporal resolution assessed with CER in the arterial phase showed higher values for us-radial-VIBE (p = 0.028). Subjective image quality parameters received generally slightly higher scores for 3D GRE VIBE. In a smaller subgroup comprising patients with severe respiratory artifacts also at reference breathhold 3D GRE VIBE examination, us-radial-VIBE showed significantly higher image quality scores. Furthermore, there were generally more severe respiratory artifacts in 3D GRE VIBE, whereas streaking was characteristic in almost all us-radial-VIBE acquisitions but did not affect diagnostic validity. Conclusion: Free-breathing dynamic liver imaging using us-radial-VIBE delivers accurate temporal resolution, low motion artifact susceptibility and good image quality and represents a promising alternative in patients unable to suspend respiration. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:26 / 32
页数:7
相关论文
共 50 条
  • [1] Contrast-enhanced free-breathing 3D T1-weighted gradient-echo sequence for hepatobiliary MRI in patients with breath-holding difficulties
    C. S. Reiner
    A. M. Neville
    H. K. Nazeer
    S. Breault
    B. M. Dale
    E. M. Merkle
    M. R. Bashir
    European Radiology, 2013, 23 : 3087 - 3093
  • [2] Contrast-enhanced free-breathing 3D T1-weighted gradient-echo sequence for hepatobiliary MRI in patients with breath-holding difficulties
    Reiner, C. S.
    Neville, A. M.
    Nazeer, H. K.
    Breault, S.
    Dale, B. M.
    Merkle, E. M.
    Bashir, M. R.
    EUROPEAN RADIOLOGY, 2013, 23 (11) : 3087 - 3093
  • [3] Free-Breathing 3D T1-Weighted Gradient-Echo Sequence With Radial Data Sampling in Abdominal MRI: Preliminary Observations
    Azevedo, Rafael M.
    de Campos, Rafael O. P.
    Ramalho, Miguel
    Heredia, Vasco
    Dale, Brian M.
    Semelka, Richard C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (03) : 650 - 657
  • [4] Navigated three-dimensional T1-weighted gradient-echo sequence for gadoxetic acid liver magnetic resonance imaging in patients with limited breath-holding capacity
    Yoon, Jeong Hee
    Lee, Jeong Min
    Lee, Eun Sun
    Baek, Jeehyun
    Lee, Sangwoo
    Iwadate, Yuji
    Han, Joon Koo
    Choi, Byung Ihn
    ABDOMINAL IMAGING, 2015, 40 (02): : 278 - 288
  • [5] Navigated three-dimensional T1-weighted gradient-echo sequence for gadoxetic acid liver magnetic resonance imaging in patients with limited breath-holding capacity
    Jeong Hee Yoon
    Jeong Min Lee
    Eun Sun Lee
    Jeehyun Baek
    Sangwoo Lee
    Yuji Iwadate
    Joon Koo Han
    Byung Ihn Choi
    Abdominal Imaging, 2015, 40 : 278 - 288
  • [6] Free-Breathing Radial 3D Fat-Suppressed T1-Weighted Gradient-Echo Sequence for Contrast-Enhanced Pediatric Spinal Imaging: Comparison With T1-Weighted Turbo Spin-Echo Sequence
    Cho, Hyun-Hae
    Choi, Young Hun
    Cheon, Jung-Eun
    Lee, So Mi
    Kim, Woo Sun
    Kim, In-One
    Paek, MunYoung
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (01) : 177 - 182
  • [7] Free-Breathing Radial 3D Fat-Suppressed T1-Weighted Gradient Echo Sequence A Viable Alternative for Contrast-Enhanced Liver Imaging in Patients Unable to Suspend Respiration
    Chandarana, Hersh
    Block, Tobias K.
    Rosenkrantz, Andrew B.
    Lim, Ruth P.
    Kim, Danny
    Mossa, David J.
    Babb, James S.
    Kiefer, Berthold
    Lee, Vivian S.
    INVESTIGATIVE RADIOLOGY, 2011, 46 (10) : 648 - 653
  • [8] Free-breathing dynamic T1WI using compressed sensing-golden angle radial sparse parallel imaging for liver MRI in patients with limited breath-holding capability
    Park, Jin Young
    Lee, Sang Min
    Lee, Jeong Sub
    Chang, Won
    Yoon, Jeong Hee
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 152
  • [9] Feasibility of free-breathing T1-weighted 3D radial VIBE for fetal MRI in various anomalies
    Sun, Taotao
    Jiang, Ling
    Zhang, Zhongshuai
    Zhang, Chen
    Zhang, He
    Wang, Guangbin
    Qian, Zhaoxia
    MAGNETIC RESONANCE IMAGING, 2020, 69 : 57 - 64
  • [10] Free-breathing radial 3D fat-suppressed T1-weighted gradient echo (r-VIBE) sequence for assessment of pulmonary lesions: a prospective comparison of CT and MRI
    Yu, Nan
    Duan, Haifeng
    Yang, Chuangbo
    Yu, Yong
    Dang, Shan
    CANCER IMAGING, 2021, 21 (01)