Effect of Implant Divergence on the Accuracy of Definitive Casts Created from Traditional and Digital Implant-Level Impressions: An In Vitro Comparative Study

被引:66
|
作者
Lin, Wei-Shao [1 ]
Harris, Bryan T. [1 ]
Elathamna, Eiad N. [1 ]
Abdel-Azim, Tamer [1 ]
Morton, Dean [1 ,2 ]
机构
[1] Univ Louisville, Sch Dent, Dept Oral Hlth & Rehabil, Louisville, KY 40292 USA
[2] Univ Louisville, Sch Dent, Adv Educ Prosthodont, Louisville, KY 40292 USA
关键词
dental implants; dental impression technique; digital impression; implant divergence; parallel confocal technology; RESTORATIONS; ANGULATION; PROSTHESES; FIT; TECHNOLOGY; FRAMEWORK; ABUTMENT;
D O I
10.11607/jomi.3592
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this research was to compare the accuracy of definitive casts created with digital and conventional methods for implants with internal-octagon connections placed parallel or at different angles (15, 30, or 45 degrees). Materials and Methods: Four customized epoxy resin master casts were fabricated with two-implant analogs placed in the posterior mandible with different degrees of divergence. For the conventional (control) group, 10 traditional impressions were taken on each master cast with custom trays, open-tray impression copings, and polyvinyl siloxane; definitive stone casts were poured with type IV dental stone. For the digital group, 10 digital impressions were taken on each master cast with two-piece scannable impression copings and an intraoral digital scanner; definitive milled polyurethane casts were fabricated by the manufacturer. All four master casts and 80 control and test casts were scanned and digitized, and the data sets were compared. Any deviations in measurements between the definitive and corresponding master casts were analyzed statistically. Results: The amount of divergence between implants did not affect the accuracy of the stone casts created conventionally; however, it significantly affected the accuracy of the milled casts created digitally. A decreasing linear trend in deviations for both distance and angle measurements suggested that the digital technique was more accurate when the implants diverged more. At 0 and 15 degrees of divergence, the digital method resulted in highly significantly less accurate definitive casts. At 30 and 45 degrees of divergence, however, the milled casts showed either no difference or marginal differences with casts created conventionally. Conclusion: The digital pathway produced less accurate definitive casts than the conventional pathway with the tested two-implant scenarios. To ensure passive fit of definitive prostheses, verification devices and casts may be used when materials are produced digitally.
引用
收藏
页码:102 / 109
页数:8
相关论文
共 50 条
  • [31] Accuracy of a milled digital implant surgical guide: An in vitro study
    Liu, Xiaoqian
    Liu, Jianzhang
    Feng, Hailan
    Pan, Shaoxia
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (03): : 453 - 461
  • [32] In Vitro Accuracy of Digital and Conventional Impressions for Full-Arch Implant-Supported Prostheses
    D'haese, Rani
    Vrombaut, Tom
    Roeykens, Herman
    Vandeweghe, Stefan
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (03)
  • [33] Comparison of the accuracy between conventional and various digital implant impressions for an implant-supported mandibular complete arch-fixed prosthesis: An in vitro study
    Kosago, Pitchaporn
    Ungurawasaporn, Chatcharwin
    Kukiattrakoon, Boonlert
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (07): : 616 - 624
  • [34] Accuracy of 3D Printed Implant Casts Versus Stone Casts: A Comparative Study in the Anterior Maxilla
    Banjar, Ayman
    Chen, Yo-wei
    Kostagianni, Aikaterini
    Finkelman, Matthew
    Papathanasiou, Aikaterini
    Chochlidakis, Konstantinos
    Papaspyridakos, Panos
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (09): : 783 - 788
  • [35] Digital workflow: In vitro accuracy of 3D printed casts generated from complete-arch digital implant scans
    Papaspyridakos, Panos
    Chen, Yo-Wei
    Alshawaf, Bahaa
    Kang, Kiho
    Finkelman, Matthew
    Chronopoulos, Vasilios
    Weber, Hans-Peter
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (05): : 589 - 593
  • [36] Effect of subgingival depth of implant placement on the dimensional accuracy of the implant impression: An in vitro study
    Lee, Heeje
    Ercoli, Carlo
    Funkenbusch, Paul D.
    Feng, Changyong
    JOURNAL OF PROSTHETIC DENTISTRY, 2008, 99 (02): : 107 - 113
  • [37] Impact of Different Scan Bodies and Scan Strategies on the Accuracy of Digital Implant Impressions Assessed with an Intraoral Scanner: An In Vitro Study
    Motel, Constantin
    Kirchner, Elena
    Adler, Werner
    Wichmann, Manfred
    Matta, Ragai Edward
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (04): : 309 - 314
  • [38] Do digital impressions have a greater accuracy for full-arch implant-supported reconstructions compared to conventional impressions? An in vitro study
    Shaikh, Mohsin
    Lakha, Tabrez
    Kheur, Supriya
    Qamri, Batul
    Kheur, Mohit
    THE JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2022, 22 (04) : 398 - 404
  • [39] Digital vs. conventional full-arch implant impressions: a comparative study
    Amin, Sarah
    Weber, Hans Peter
    Finkelman, Matthew
    El Rafie, Khaled
    Kudara, Yukio
    Papaspyridakos, Panos
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (11) : 1360 - 1367
  • [40] Effect of a Novel 'Scan Body' on the In Vitro Scanning Accuracy of Full-Arch Implant Impressions
    Zhang, Tingting
    Yang, Bo
    Ge, Ruihan
    Zhang, Chaobiao
    Zhang, Hui
    Wang, Yan
    INTERNATIONAL DENTAL JOURNAL, 2024, 74 (04) : 847 - 854