Influence of inspiratory capacity on bronchodilatation via Turbuhaler(R) or pressurized metered-dose inhaler in asthmatic children: A comparison

被引:15
|
作者
Hirsch, T
PeterKern, M
Koch, R
Leupold, W
机构
[1] UNIV HOSP,CHILDRENS CLIN PEDIAT PULMONOL,DRESDEN,GERMANY
[2] UNIV HOSP,INST MED INFORMAT & BIOMETR,DRESDEN,GERMANY
关键词
D O I
10.1016/S0954-6111(97)90060-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study was designed to compare the bronchodilatatory effect of terbutaline inhaled through Turbuhaler(R) (TH) or pressurized metered-dose inhaler (pMDI) in young asthmatics, and to assess the possible relationship between patients' inspiratory capacity and bronchodilatation for both devices. One hundred and eighteen asthmatics (aged 4 10/12-20 6/12 years) with bronchial obstruction (mean (V) over dotmax 50%: 59.5%(pred), SD 17.8%(pred)) were allocated at random to two groups of 59 patients to inhale 0.5 mg terbutaline either by TH or by pMDI (and placebo by dummy of the other device). In- and expiratory spirometry and bodyplethysmography were conducted before and 10 min after inhalation. Bronchodilatation was effective [change in airways resistance (Delta R-AW) -50%, change in forced expiratory volume in 1 s (Delta FEV1) + 15%, Delta(V) over dotmax 50% or 25% + 25% of baseline] in 41 of 59 patients with pMDI (69.5%) and 33 of 59 patients with TH (55.9%). The effect on (V) over dotmax 50% was significantly better with pMDI than with TH. Turbuhaler(R) users with higher inspiratory flow [forced inspiratory volume in 1 s (FIV1), forced inspiratory flow at 50% vital capacity (FIF50] reached better bronchodilatation, while bronchodilatatory effect was not correlated with inspiratory performance in MDI users. Peak inspiratory flow (PIF) did not correlate well with bronchodilatation by TH. When using TH for bronchodilatation, the effectiveness of terbutaline depends upon the degree of inspiratory capacity. This can lead to impaired bronchodilatatory effect in subgroups of obstructive young asthmatics with low inspiratory flow. In contrast, when using a pMDI, inspiratory capacity does not seem to influence the effectiveness of terbutaline.
引用
收藏
页码:341 / 346
页数:6
相关论文
共 50 条
  • [21] Efficacy and safety of budesonide administered by pressurized metered-dose inhaler in children with asthma
    Meltzer, Eli O.
    Pearlman, David S.
    Eckerwall, Goran
    Uryniak, Tom
    DePietro, Michael
    Lampl, Kathy
    ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2015, 115 (06) : 516 - 522
  • [22] Comparison of Easyhaler® metered-dose, dry powder inhaler and a pressurised metered-dose inhaler plus spacer in the treatment of asthma in children
    Juntunen-Backman, K
    Kajosaari, M
    Laurikainen, K
    Malinen, A
    Kaila, M
    Mustala, L
    Kaski, U
    Linna, O
    Marenk, M
    Toivanen, P
    CLINICAL DRUG INVESTIGATION, 2002, 22 (12) : 827 - 835
  • [23] Influence of propellant composition on drug delivery from a pressurized metered-dose inhaler
    Williams, RO
    Repka, M
    Liu, J
    DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1998, 24 (08) : 763 - 770
  • [24] COMPARISON OF INHALED TERBUTALINE ADMINISTERED BY EITHER THE TURBUHALER DRY POWDER INHALER OR A METERED-DOSE INHALER WITH SPACER IN PRESCHOOL-CHILDREN WITH ASTHMA
    LABERGE, S
    SPIER, S
    DRBLIK, SP
    TURGEON, JP
    JOURNAL OF PEDIATRICS, 1994, 124 (05): : 815 - 817
  • [25] Lung deposition and protective effect of terbutaline delivered from pressurized metered-dose inhalers and the turbuhaler in asthmatic individuals
    Derom, E
    Borgström, L
    Van Schoor, J
    Löfroos, AB
    Pauwels, R
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 164 (08) : 1398 - 1402
  • [26] Differences in bronchodilating potency of salbutamol in Turbuhaler® as compared with a pressurized metered-dose inhaler formulation in patients with reversible airway obstruction
    Lofdahl, CG
    Andersson, L
    Bondesson, E
    Carlsson, LG
    Friberg, K
    Hedner, J
    Hornblad, Y
    Jemsby, P
    Kallen, A
    Ullman, A
    Werner, S
    Svedmyr, N
    EUROPEAN RESPIRATORY JOURNAL, 1997, 10 (11) : 2474 - 2478
  • [27] Evaluation of Metered-Dose Inhaler Administration Technique among Asthmatic Children and Their Caregivers in Thailand
    Deerojanawong, Jitladda
    Sakolnakorn, Vimonmas Promsaka Na
    Prapphal, Nuanchan
    Hanrutakorn, Chantana
    Sritippayawan, Suchada
    ASIAN PACIFIC JOURNAL OF ALLERGY AND IMMUNOLOGY, 2009, 27 (2-3): : 87 - 93
  • [28] USE OF A TUBE SPACER TO IMPROVE THE EFFICACY OF A METERED-DOSE INHALER IN ASTHMATIC-CHILDREN
    RACHELEFSKY, GS
    ROHR, AS
    WO, J
    GRACEY, V
    SPECTOR, SL
    SIEGEL, SC
    KATZ, RM
    MICKEY, MR
    AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1986, 140 (11): : 1191 - 1193
  • [29] INHALATION TREATMENT WITH BUDENOSIDE IN ASTHMA - A COMPARISON OF TURBUHALER(R) AND METERED-DOSE INHALATION WITH NEBUHALER(R)
    NIEMINEN, MM
    LAHDENSUO, A
    ACTA THERAPEUTICA, 1995, 21 (3-4) : 179 - 192
  • [30] BRONCHODILATOR EFFECTS OF FORMOTEROL SINGLE DOSES ADMINISTERED BY PRESSURIZED METERED-DOSE INHALER IN ASTHMATIC CHILDREN AGED 6 TO 11 YEARS
    Berger, W. E.
    Lampl, K.
    Trudo, F.
    Uryniak, T.
    Gillen, M.
    ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2013, 111 (05) : A39 - A40