Dual-Energy Computed Tomography-Based Display of Bone Marrow Edema in Incidental Vertebral Compression Fractures Diagnostic Accuracy and Characterization in Oncological Patients Undergoing Routine Staging Computed Tomography

被引:42
|
作者
Frellesen, Claudia [1 ]
Azadegan, Mehrnoush [1 ]
Martin, Simon S. [1 ]
Otani, Katharina [2 ]
D'Angelo, Tommaso [3 ]
Booz, Christian [1 ]
Eichler, Katrin [1 ]
Panahi, Bita [1 ]
Kaup, Moritz [1 ]
Bauer, Ralf W. [4 ]
Vogl, Thomas J. [1 ]
Wichmann, Julian L. [1 ]
机构
[1] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Frankfurt, Germany
[2] Siemens Japan KK, Imaging & Therapy Syst Div, Healthcare Sect, Tokyo, Japan
[3] Univ Messina, Dept Biomed Sci & Morphol & Funct Imaging, Messina, Italy
[4] RNS Gemeinschaftspraxis GbR, Wiesbaden, Germany
关键词
dual-energy CT; bone marrow edema; vertebral compression fracture; qualitative analysis; characterization; VIRTUAL NONCALCIUM TECHNIQUE; MULTIDETECTOR CT; IMAGE-QUALITY; ANGIOGRAPHY; PERFORMANCE; ABDOMEN; CANCER; DIFFERENTIATION; RADIOLOGISTS; FEASIBILITY;
D O I
10.1097/RLI.0000000000000458
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study was to evaluate the diagnostic performance of virtual noncalcium (VNCa) dual-energy computed tomography (DECT) reconstructions enabling visualization of bone marrow edema for characterization of incidental thoracolumbar compression fractures in routine thoracoabdominal staging computed tomography (CT). Materials and Methods: We retrospectively analyzed 51 oncological patients without suspected fracture or indicative complaints presenting at least 1 thoracolumbar compression fracture on routine thoracoabdominal staging DECT who had been examined between October 2015 and June 2017 using third-generation dual-source CT, had a previous CT within 3 months before, and also had undergone additional magnetic resonance imaging within 14 days, which served as the standard of reference. Three independent and blinded radiologists initially evaluated all vertebrae on conventional grayscale DECT series; after at least 8 weeks, observers reevaluated all cases using grayscale and color-coded VNCa DECT images. The age of each fracture was determined as either acute, chronic, or inconclusive. Specificity, sensitivity, and intraobserver and interobserver agreements were calculated taking into account clustering. Results: A total of 98 vertebral compression fractures were detected in 51 patients (20 women, 31 men; median of 1 fracture per patient). The reference standard defined 45 as acute and 53 as chronic. For identification of only acute fractures (cutoff 1), the combination of grayscale and VNCa image series showed a higher sensitivity (91% vs 47%; P < 0.001) but equal specificity (both 100%) compared with analysis of grayscale images alone. When defining a positive finding as a fracture considered either acute or inconclusive (cutoff 2), combined analysis of grayscale and VNCa images showed similar sensitivity (96% vs 93%; P = 0.28) but significantly higher specificity (96% vs 75%; P < 0.001) compared with evaluation of grayscale images alone. Area under the curve analysis for detection of vertebral compression fractures showed superior results for reading of grayscale and VNCa image series (0.98) compared with analysis of grayscale images alone (0.89; P < 0.001). Conclusion: Dual-energy CT-derived color-coded VNCa reconstructions substantially improve the characterization of incidental thoracolumbar compression fractures seen on routine thoracoabdominal staging DECT by allowing for visualization of bone marrow edema.
引用
收藏
页码:409 / 416
页数:8
相关论文
共 50 条
  • [21] Accuracy and applicability of dual-energy computed tomography in quantifying vertebral bone marrow adipose tissue compared with magnetic resonance imaging
    Liu, Zhenghua
    Huang, Dageng
    Zhang, Yuting
    Chang, Rong
    Zhang, Xiaoyue
    Jiang, Yonghong
    Ma, Xiaowen
    INSIGHTS INTO IMAGING, 2022, 13 (01)
  • [22] Dual-energy computed tomography-based radiomics for differentiating patients with and without gout flares
    Hu, Yabin
    Liu, Shunli
    Ren, Wei
    Dalbeth, Nicola
    Zhou, Rui
    Chen, Yizhe
    Pan, Yuehai
    He, Yuwei
    Liu, Zhen
    Jia, Zhaotong
    Ge, Yaqiong
    Du, Yue
    Han, Lin
    CLINICAL RHEUMATOLOGY, 2024, 43 (12) : 3869 - 3877
  • [23] Diagnostic accuracy of dual-energy computed tomography (DECT) to detect non-traumatic bone marrow edema: A systematic review and meta-analysis
    Chen, Zheng
    Chen, Yingmin
    Zhang, Hui
    Jia, Xiuchuan
    Zheng, Xuechao
    Zuo, Tianzi
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 153
  • [24] Diagnostic accuracy of dual-energy CT and virtual non-calcium techniques to evaluate bone marrow edema in vertebral compression fractures
    Giovanni Foti
    Alberto Beltramello
    Matteo Catania
    Stefano Rigotti
    Gerardo Serra
    Giovanni Carbognin
    La radiologia medica, 2019, 124 : 487 - 494
  • [25] Diagnostic accuracy of dual-energy CT and virtual non-calcium techniques to evaluate bone marrow edema in vertebral compression fractures
    Foti, Giovanni
    Beltramello, Alberto
    Catania, Matteo
    Rigotti, Stefano
    Serra, Gerardo
    Carbognin, Giovanni
    RADIOLOGIA MEDICA, 2019, 124 (06): : 487 - 494
  • [26] Detection of bone marrow edema in osteonecrosis of the femoral head using virtual noncalcium dual-energy computed tomography
    Zuo, Tianzi
    Chen, Yingmin
    Zheng, Hongming
    Jia, Xiuchuan
    Bao, Yunfeng
    Wang, Yuhang
    Li, Ling
    Huang, Xiaoying
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 139
  • [27] Dual-Energy CT-based Display of Bone Marrow Edema in Osteoporotic Vertebral Compression Fractures: Impact on Diagnostic Accuracy of Radiologists with Varying Levels of Experience in Correlation to MR Imaging
    Kaup, Moritz
    Wichmann, Julian L.
    Scholtz, Jan-Erik
    Beeres, Martin
    Kromen, Wolfgang
    Albrecht, Moritz H.
    Lehnert, Thomas
    Boettcher, Marie
    Vogl, Thomas J.
    Bauer, Ralf W.
    RADIOLOGY, 2016, 280 (02) : 510 - 519
  • [28] Dual-Energy CT of Material Decomposition Analysis for Detection with Bone Marrow Edema in Patients with Vertebral Compression Fractures
    Akisato, Kyouhei
    Nishihara, Reisuke
    Okazaki, Hajime
    Masuda, Takanori
    Hironobe, Ayako
    Ishizaki, Hiromi
    Shota, Kondo
    Yamaguchi, Hiroshi
    Funama, Yoshinori
    ACADEMIC RADIOLOGY, 2020, 27 (02) : 227 - 232
  • [30] A quantitative assessment of dual energy computed tomography-based material decomposition for imaging bone marrow edema associated with acute knee injury
    de Bakker, Chantal M. J.
    Walker, Richard E. A.
    Besler, Bryce A.
    Tse, Justin J.
    Manske, Sarah L.
    Martin, C. Ryan
    French, Stephen J.
    Dodd, Andrew E.
    Boyd, Steven K.
    MEDICAL PHYSICS, 2021, 48 (04) : 1792 - 1803