Liquid Biopsy of Bile based on Targeted Mass Spectrometry for the Diagnosis of Malignant Biliary Strictures

被引:7
|
作者
Adrait, Annie [1 ]
Dumonceau, Jean-Marc [2 ]
Delhaye, Myriam [3 ]
Annessi-Ramseyer, Isabelle [4 ]
Frossard, Jean-Louis [4 ,5 ]
Coute, Yohann [1 ]
Farina, Annarita [4 ,5 ]
机构
[1] Univ Grenoble Alpes, CEA, INSERM, IRIG,BGE, Grenoble, France
[2] Hop Civil Marie Curie, Gastroenterol Serv, Charleroi, Belgium
[3] Erasme Univ Hosp, Dept Gastroenterol Hepatopancreatol & GI Oncol, Brussels, Belgium
[4] Univ Geneva, Dept Med, Geneva, Switzerland
[5] Geneva Univ Hosp, Div Gastroenterol, Geneva, Switzerland
来源
关键词
PROTEOMIC ANALYSIS; EXTRACELLULAR VESICLES; CANCER; BIOMARKERS;
D O I
10.1111/cts.12890
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Bile holds biomarkers of malignant biliary strictures (MBS) but is unsuited for automated analyzers used in routine diagnostic laboratories. Selected reaction monitoring (SRM) is a flexible high-throughput analytical approach based on targeted mass spectrometry (MS) already implemented in clinical settings. We tested the hypothesis that SRM could be used to quantify cancer biomarkers in human bile. An SRM-based assay was developed to simultaneously quantify up to 37 peptides from 13 bile proteins in a developmental cohort of 15 patients (MBS, n = 8; benign biliary stricture or obstruction (BBS), n = 7). The most reliable biomarkers were then absolutely quantified by SRM in a verification cohort of 67 patients (MBS, n = 37; BBS, n = 30). The diagnostic performances of single and combined biomarkers were assessed. In the developmental cohort, SRM-based analysis revealed six protein biomarkers with significantly higher peptide ratios (endogenous vs. standard) in bile from MBS vs. BBS. In the verification cohort, five of these biomarkers proved good diagnostic ability (individual receiver operating characteristic-area under the receiver operating characteristic curve (ROC-AUC) up to 0.889, accuracies from 67.8% to 83.1%). Combining bile biomarkers and serum CA19-9 in 2 panels allowed differentiating MBS from BBS with up to 0.929 ROC-AUC and 89.8% accuracy. In this study, a newly developed SRM-based assay proved able to simultaneously quantify multiple biomarkers in bile samples. The combination of bile biomarkers with serum CA19-9 was highly accurate for the diagnosis of MBS. Liquid biopsy of bile based on targeted MS is eligible to support MBS diagnosis in clinical practice.
引用
收藏
页码:148 / 152
页数:5
相关论文
共 50 条
  • [21] Transpapillary biliary biopsy for malignant biliary strictures: comparison between cholangiocarcinoma and pancreatic cancer
    Chen, Wei-Ming
    Wei, Kuo-Liang
    Chen, Yi-Shing
    Chang, Pey-Jium
    Tung, Shui-Yi
    Chang, Te-Sheng
    Huang, Hao-Chun
    Shen, Chein-Heng
    Hsieh, Yung-Yu
    Wu, Cheng-Shyong
    WORLD JOURNAL OF SURGICAL ONCOLOGY, 2016, 14
  • [22] ENDOSCOPIC NEEDLE ASPIRATION BIOPSY AT ERCP IN THE DIAGNOSIS OF BILIARY STRICTURES
    HOWELL, DA
    BEVERIDGE, RP
    BOSCO, J
    JONES, M
    GASTROINTESTINAL ENDOSCOPY, 1992, 38 (05) : 531 - 535
  • [23] Diagnostic value of new biliary biopsy cannulae for malignant bile duct strictures via endoscopic retrograde cholangiopancreatography pathway
    Zhuang, Meng-Qi
    Zheng, Cheng
    Xie, Wei-Wei
    Xu, Lin
    Wu, Jia-Li
    Zhang, Dao-Quan
    Chen, Yuan-Gan
    Niu, Sen-Sen
    Zhan, Xiang
    Zhou, Yu-Bao
    ASIAN JOURNAL OF SURGERY, 2024, 47 (01) : 471 - 476
  • [24] Clinical significance of bile cytology via an endoscopic nasobiliary drainage tube for pathological diagnosis of malignant biliary strictures
    Yagioka, Hiroshi
    Hirano, Kenji
    Isayama, Hiroyuki
    Tsujino, Takeshi
    Sasahira, Naoki
    Nagano, Rie
    Hamada, Tsuyoshi
    Miyabayashi, Koji
    Ito, Yukiko
    Mohri, Dai
    Kawakubo, Kazumichi
    Kogure, Hirofumi
    Sasaki, Takashi
    Tada, Minoru
    Koike, Kazuhiko
    JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES, 2011, 18 (02) : 211 - 215
  • [25] Utility of methylated DNA markers for the diagnosis of malignant biliary strictures
    Cooley, Matthew A.
    Schneider, Amber R.
    Barr Fritcher, Emily G.
    Milosevic, Dragana
    Levy, Michael J.
    Bridgeman, Amber R.
    Martin, John A.
    Petersen, Bret T.
    Abu Dayyeh, Barham K.
    Storm, Andrew C.
    Law, Ryan J.
    Vargas, Eric J.
    Garimella, Vishal
    Zemla, Tyler
    Jenkins, Sarah M.
    Yin, Jun
    Gores, Gregory J.
    Roberts, Lewis R.
    Kipp, Benjamin R.
    Chandrasekhara, Vinay
    HEPATOLOGY, 2024,
  • [26] Bile proteomics for differentiation of malignant from benign biliary strictures: a pilot study
    Navaneethan, Udayakumar
    Lourdusamy, Vennisvasanth
    Venkatesh, Preethi G. K.
    Willard, Belinda
    Sanaka, Madhusudhan R.
    Parsi, Mansour A.
    GASTROENTEROLOGY REPORT, 2015, 3 (02): : 136 - 143
  • [27] ASSESSMENT OF INTRADUCTAL BIOPSY AND BRUSH CYTOLOGY IN THE ETIOLOGIC DIAGNOSIS OF BILIARY STRICTURES
    PALIARD, P
    PONCHON, T
    LABADIE, M
    BERGER, F
    BRET, PA
    MAIZA, E
    BRETAGNOLLE, M
    CHAVAILLON, A
    VALETTE, PJ
    GASTROENTEROLOGIE CLINIQUE ET BIOLOGIQUE, 1987, 11 (6-7): : 449 - 452
  • [28] Percutaneous transluminal forceps biopsy: Experience in 130 patients with malignant biliary strictures
    Jung, GS
    Lee, S
    Han, B
    Chang, H
    Huh, J
    Cho, YD
    RADIOLOGY, 2001, 221 : 352 - 352
  • [29] The utilities and complications of the endoscopic transpapillary forceps biopsy for diagnosis of the biliary strictures
    Kawashima, H.
    Hirooka, Y.
    Itoh, A.
    Ohno, E.
    Ishikawa, T.
    Matsubara, H.
    Itoh, Y.
    Nakamura, M.
    Miyahara, R.
    Ohmiya, N.
    Niwa, Y.
    Goto, H.
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2009, 24 : A124 - A125
  • [30] Prospective evaluation of the performance of per ERCP bile aspiration combined to endobiliary brushing in the diagnosis of malignant strictures of the biliary tract
    Gael, Roth
    Philippe, Bichard
    Michele, Fior-Gozlan
    Jean, Auroux
    Letoublon, Christian
    Bricault, Ivan
    Leroy, Vincent
    Decaens, Thomas
    HEPATOLOGY, 2014, 60 : 840A - 841A