One Year Change in 6-Minute Walk Test Outcomes is Associated with COPD Prognosis

被引:6
|
作者
Waatevik, Marie [1 ]
Frisk, Bente [2 ,3 ]
Real, Francisco Gomez [4 ,5 ]
Hardie, Jon Andrew [4 ]
Bakke, Per [4 ]
Nilsen, Roy Miodini [6 ]
Eagan, Tomas Mikal [4 ,7 ]
Johannessen, Ane [8 ]
机构
[1] Haukeland Hosp, Ctr Clin Res, N-5021 Bergen, Norway
[2] Western Norway Univ Appl Sci, Dept Hlth & Functioning, Bergen, Norway
[3] Haukeland Hosp, Dept Physiotherapy, Bergen, Norway
[4] Univ Bergen, Dept Clin Sci, Bergen, Norway
[5] Haukeland Hosp, Dept Gynecol & Obstet, Bergen, Norway
[6] Western Norway Univ Appl Sci, Fac Hlth & Social Sci, Bergen, Norway
[7] Haukeland Hosp, Dept Thorac Med, Bergen, Norway
[8] Univ Bergen, Ctr Int Hlth, Dept Global Publ Hlth & Primary Care, Bergen, Norway
关键词
COPD; 6MWT; desaturation; exercise; mortality; lung function; OXYGEN DESATURATION; DISTANCE; GUIDELINES; MORTALITY; TIME;
D O I
10.1080/15412555.2020.1839041
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Six-minute walk test (6MWT) measures walking distance (6MWD) and desaturation status in chronic obstructive pulmonary disease (COPD) patients. This study aimed to examine whether change in 6MWD and desaturation in 1 year were risk factors for later mortality, lung function decline and number of exacerbations. A total of 295 COPD patients performed 6MWT at baseline and 1 year later in the Bergen COPD cohort study 2006-2011. They were clinically examined and interviewed at annual visits. Mortality information was collected from the Norwegian Cause of Death Registry in 2015. We performed cox regression for mortality outcomes, linear mixed effect models for lung function, and negative binomial regression for exacerbations. Patients who desaturated in both 6MWTs had increased risk of all-cause and respiratory mortality, hazard ratio (HR) 2.7 (95% confidence interval [CI] 1.5-5.0) and 3.6 (95% CI 1.7-7.6), respectively, compared to non-desaturators. Patients who desaturated only at second 6MWT were at risk for all-cause mortality (HR 2.0, 95% CI 1.0-3.8). There were no apparent association between 6MWD and mortality. Desaturation in second 6MWT was associated with later increased rate of decline in forced vital capacity (FVC) % predicted (after 1 year predicted mean 4.2% above non-desaturators, after 5 years 0.7% below). Decline in 6MWD >= 30m was borderline (p = 0.06) associated with later decline in forced expiratory volume in 1 second % predicted, and with exacerbations (p = 0.07). Repeated desaturation in the 6MWT over time in COPD patients is a risk factor for all-cause and respiratory mortality, while onset of desaturation is associated with future FVC decline.
引用
收藏
页码:662 / 671
页数:10
相关论文
共 50 条
  • [31] Reproducibility of the 6-minute Walk Test in Obese Adults
    Beriault, K.
    Carpentier, A. C.
    Gagnon, C.
    Menard, J.
    Baillargeon, J. -P.
    Ardilouze, J. -L.
    Langlois, M. -F.
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2009, 30 (10) : 725 - 727
  • [32] Clinical determinants of the 6-Minute Walk Test in bronchiectasis
    Lee, A. L.
    Button, B. M.
    Ellis, S.
    Stirling, R.
    Wilson, J. W.
    Holland, A. E.
    Denehy, L.
    RESPIRATORY MEDICINE, 2009, 103 (05) : 780 - 785
  • [33] Evaluation of the 6-Minute Walk Test in Pet Dogs
    Swimmer, R. A.
    Rozanski, E. A.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2011, 25 (02): : 405 - 406
  • [34] A Smartphone Approach for the 2 and 6-minute Walk Test
    Capela, Nicole A.
    Lemaire, Edward D.
    Baddour, Natalie C.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 958 - 961
  • [35] Reliability and Validity of the 6-Minute Walk Test in Hypophosphatasia
    Phillips, Dawn
    Tomazos, Ioannis C.
    Moseley, Scott
    L'Italien, Gil
    Gomes da Silva, Hugo
    Lerma Lara, Sergio
    JBMR PLUS, 2019, 3 (06)
  • [36] Safety of the 6-minute walk test in severe asthma
    de Oliveira, J.
    Guerrero, Urroz P.
    Lewthwaite, H.
    Clark, V
    Gibson, P.
    McDonald, V
    RESPIROLOGY, 2024, 29 : 132 - 132
  • [37] Factors associated with the 6-minute walk test performance in older adults with hyperkyphosis
    Fukuoka, Yoshimi
    Katzman, Wendy B.
    Gladin, Amy
    Lane, Nancy E.
    Yoo, Jung Oh
    GERIATRIC NURSING, 2022, 47 : 95 - 99
  • [38] FACTORS ASSOCIATED WITH THE 6-MINUTE WALK TEST AMONG PERSONS WITH RHEUMATOID ARTHRITIS
    Houge, I. S.
    Hoff, M.
    Videm, V.
    ANNALS OF THE RHEUMATIC DISEASES, 2022, 81 : 564 - 564
  • [39] May Desaturation During 6-Minute Walk Test Predict Nocturnal Desaturation In COPD Patients?
    Dos Reis, L. V. T.
    Faria, A. C.
    Bessa, E. J. C.
    Chibante, F. D. O.
    Rufino, R.
    Costa, C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 195
  • [40] Clinical characteristics of COPD patients with early-onset desaturation in the 6-minute walk test
    Garcia-Talavera, I.
    Figueira-Goncalves, J. M.
    Gurbani, N.
    Perez-Mendez, L.
    Pedrero-Garcia, A.
    PULMONOLOGY, 2018, 24 (05): : 275 - 279