High-Throughput Biophysical Analysis and Data Visualization of Conformational Stability of an IgG1 Monoclonal Antibody After Deglycosylation

被引:25
|
作者
Alsenaidy, Mohammad A. [1 ]
Kim, Jae Hyun [2 ]
Majumdar, Ranajoy [1 ]
Weis, David D. [2 ]
Joshi, Sangeeta B. [1 ]
Tolbert, Thomas J. [1 ]
Middaugh, C. Russell [1 ]
Volkin, David B. [1 ]
机构
[1] Univ Kansas, Macromol & Vaccine Stabilizat Ctr, Dept Pharmaceut Chem, Lawrence, KS 66047 USA
[2] Univ Kansas, Dept Chem, Lawrence, KS 66045 USA
关键词
glycosylation; monoclonal antibody; stability; structure; conformation; biophysical; formulation; HIGH-MANNOSE; POSTTRANSLATIONAL MODIFICATIONS; THERMAL-STABILITY; SERUM CLEARANCE; FC DOMAIN; GLYCOSYLATION; AGGREGATION; DYNAMICS; IMPACT; ACID;
D O I
10.1002/jps.23730
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
The structural integrity and conformational stability of an IgG1 monoclonal antibody (mAb), after partial or complete enzymatic removal of the N-linked Fc glycan, were compared with the untreated mAb over a wide range of temperature (10 degrees C-90 degrees C) and solution pH (3-8) using circular dichroism, fluorescence spectroscopy, and static light scattering combined with data visualization employing empirical phase diagrams. Subtle-to-larger stability differences between the different glycoforms were observed. Improved detection of physical stability differences was then demonstrated over narrower pH range (4.0-6.0) using smaller temperature increments, especially when combined with an alternative data visualization method (radar plots). Differential scanning calorimetry and differential scanning fluorimetry were then utilized and also showed an improved ability to detect differences in the physical stability of a mAb glycoform. On the basis of these results, a two-step methodology was used in which conformational stability of a mAb glycoform is first screened with a wide variety of instruments and environmental stresses, followed by a second evaluation with optimally sensitive experimental conditions, analytical techniques, and data visualization methods. With this approach, a high-throughput biophysical analysis to assess relatively subtle conformational stability differences in protein glycoforms is demonstrated. (c) 2013 Wiley Periodicals, Inc. and the American Pharmacists Association J Pharm Sci 102:3942-3956, 2013
引用
收藏
页码:3942 / 3956
页数:15
相关论文
共 50 条
  • [41] Application of a High-Throughput Screening Procedure with PEG-Induced Precipitation to Compare Relative Protein Solubility During Formulation Development with IgG1 Monoclonal Antibodies
    Gibson, Todd J.
    Mccarty, Katie
    Mcfadyen, Iain J.
    Cash, Ethan
    Dalmonte, Paul
    Hinds, Kenneth D.
    Dinerman, Adam A.
    Alvarez, Juan C.
    Volkin, David B.
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2011, 100 (03) : 1009 - 1021
  • [42] NASQAR: a web-based platform for high-throughput sequencing data analysis and visualization
    Yousif, Ayman
    Drou, Nizar
    Rowe, Jillian
    Khalfan, Mohammed
    Gunsalus, Kristin C.
    BMC BIOINFORMATICS, 2020, 21 (01)
  • [43] HTSvis: a web app for exploratory data analysis and visualization of arrayed high-throughput screens
    Scheeder, Christian
    Heigwer, Florian
    Boutros, Michael
    BIOINFORMATICS, 2017, 33 (18) : 2960 - 2962
  • [44] NASQAR: a web-based platform for high-throughput sequencing data analysis and visualization
    Ayman Yousif
    Nizar Drou
    Jillian Rowe
    Mohammed Khalfan
    Kristin C. Gunsalus
    BMC Bioinformatics, 21
  • [45] Parallel development of chromatographic and mass-spectrometric methods for quantitative analysis of glycation on an IgG1 monoclonal antibody
    Viski, Kornel
    Gengeliczki, Zsolt
    Lenkey, Krisztian
    Ganzler, Katalin Baranyane
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1032 : 198 - 204
  • [46] Variable domain mutational analysis to probe the molecular mechanisms of high viscosity of an IgG1 antibody
    Dai, Jing
    Izadi, Saeed
    Zarzar, Jonathan
    Wu, Patrick
    Oh, Angela
    Carter, Paul J.
    MABS, 2024, 16 (01)
  • [47] High Resolution LC-MS Analysis of Reduced IgG1 Monoclonal Antibody Fragments Using HALO Protein C4
    Schuster, Stephanie A.
    Boyes, Barry E.
    LC GC NORTH AMERICA, 2014, : 10 - 10
  • [48] High-throughput melting-temperature analysis of a monoclonal antibody by differential scanning fluorimetry in the presence of surfactants
    Menzen, Tim
    Friess, Wolfgang
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2013, 102 (02) : 415 - 428
  • [49] ExpoSeq: simplified analysis of high-throughput sequencing data from antibody discovery campaigns
    Sorensen, Christoffer, V
    Hofmann, Nils
    Rawat, Puneet
    Sorensen, Frederik, V
    Ljungars, Anne
    Greiff, Victor
    Laustsen, Andreas H.
    Jenkins, Timothy P.
    BIOINFORMATICS ADVANCES, 2024, 4 (01):
  • [50] High-throughput analysis system of interaction kinetics for data-driven antibody design
    Matsunaga R.
    Ujiie K.
    Inagaki M.
    Fernández Pérez J.
    Yasuda Y.
    Mimasu S.
    Soga S.
    Tsumoto K.