Concurrent Validity of Wearable Activity Trackers Under Free-Living Conditions

被引:52
|
作者
Brooke, Skyler M. [1 ]
An, Hyun-Sung [1 ]
Kang, Seoung-Ki [2 ]
Noble, John M. [1 ]
Berg, Kris E. [1 ]
Lee, Jung-Min [1 ]
机构
[1] Univ Nebraska, Sch Hlth Phys Educ & Recreat, Omaha, NE 68182 USA
[2] Yong In Univ, Grad Sch Educ, Yongin, South Korea
关键词
sleep period time; energy expenditure; physical activity assessment; PHYSICAL-ACTIVITY; ACTIVITY MONITORS; ENERGY-EXPENDITURE; HEALTHY-ADULTS; SLEEP; CHILDREN; ADOLESCENTS; VALIDATION; CONSUMER; POLYSOMNOGRAPHY;
D O I
10.1519/JSC.0000000000001571
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Brooke, SM, An, H-S, Kang, S-K, Noble, JM, Berg, KE, and Lee, J-M. Concurrent validity of wearable activity trackers under free-living conditions. J Strength Cond Res 31(4): 1097-1106, 2017The purpose of this study is to evaluate the concurrent validity of wearable activity trackers in energy expenditure (EE) and sleep period time (SPT) under free-living conditions. Ninety-five (28.5 +/- 9.8 years) healthy men (n = 34) and women (n = 61) participated in this study. The total EE and SPT were measured using 8 monitors: Nike+ FuelBand SE (NFB), Garmin VivoFit (VF), Misfit Shine (MF), Fitbit Flex (FF), Jawbone UP (JU), Polar Loop (PL), Fitbit Charge HR (FC), and SenseWear Armband Mini (SWA) (criterion measures: SWA for EE and a sleep log for SPT). The mean absolute percent error (MAPE) for EE was 13.0, 15.2, 15.5, 16.1, 16.2, 22.8, and 24.5% for PL, MF, FF, NFB, FC, JU, and VF, respectively. Mean absolute percent errors were calculated for SPT to be 4.0, 8.8, 10.2, 11.5, 12.9, 13.6, 17.5, and 21.61% for VF, FF, JU, FC, MF, SWA laying down, PL, and SWA, respectively. Concurrent validity was examined using equivalence testing on EE (equivalence zone: 2,889.7-3,531.9 kcal); 2 trackers fell short of falling in the zone: PL (2,714.4-3,164.8 kcal) and FC (2,473.8-3,066.5 kcal). For SPT (equivalence zone: 420.6-514.0 minutes), several monitors fell in the zone: PL (448.3-485.6 minutes), MS (442.8-492.2 minutes), and FF (427.7-486.7 minutes). This study suggests that the PL and FC provide a reasonable estimate of EE under free-living conditions. The PL, FC, and MF were the most valid monitors used for measuring SPT.
引用
收藏
页码:1097 / 1106
页数:10
相关论文
共 50 条
  • [41] Development of a Multisensory Wearable System for Monitoring Cigarette Smoking Behavior in Free-Living Conditions
    Imtiaz, Masudul Haider
    Ramos-Garcia, Raul I.
    Senyurek, Volkan Yusuf
    Tiffany, Stephen
    Sazonov, Edward
    ELECTRONICS, 2017, 6 (04): : 1 - 21
  • [42] Systematic review of the validity and reliability of consumer-wearable activity trackers
    Evenson, Kelly R.
    Goto, Michelle M.
    Furberg, Robert D.
    INTERNATIONAL JOURNAL OF BEHAVIORAL NUTRITION AND PHYSICAL ACTIVITY, 2015, 12
  • [43] Systematic review of the validity and reliability of consumer-wearable activity trackers
    Kelly R. Evenson
    Michelle M. Goto
    Robert D. Furberg
    International Journal of Behavioral Nutrition and Physical Activity, 12
  • [44] Concurrent validity of the ActiGraph GT3X+and activPAL for assessing sedentary behaviour in 2-3-year-old children under free-living conditions
    Pereira, Joao R.
    Sousa-Sa, Eduarda
    Zhang, Zhiguang
    Cliff, Dylan P.
    Santos, Rute
    JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2020, 23 (02) : 151 - 156
  • [45] Validity of Wearable Monitors and Smartphone Applications for Measuring Steps in Semi-Structured and Free-Living Settings
    Adamakis, Manolis
    TECHNOLOGIES, 2023, 11 (01)
  • [46] The Smart Fall Detection Mechanism for Healthcare Under Free-Living Conditions
    Gwo-Jiun Horng
    Kai-Hong Chen
    Wireless Personal Communications, 2021, 118 : 715 - 753
  • [47] Comparison of Lifecorder EX and ActiGraph accelerometers under free-living conditions
    McClain, James J.
    Craig, Cora L.
    Sisson, Susan B.
    Tudor-Locke, Catrine
    APPLIED PHYSIOLOGY NUTRITION AND METABOLISM, 2007, 32 (04) : 753 - 761
  • [48] The Smart Fall Detection Mechanism for Healthcare Under Free-Living Conditions
    Horng, Gwo-Jiun
    Chen, Kai-Hong
    WIRELESS PERSONAL COMMUNICATIONS, 2021, 118 (01) : 715 - 753
  • [49] Impact of Placement of Fitbit HR under Laboratory and Free-Living Conditions
    Jung, Hyun Chul
    Kang, Minsoo
    Lee, Nan Hee
    Jeon, Soeun
    Lee, Sukho
    SUSTAINABILITY, 2020, 12 (16)
  • [50] Appetite changes under free-living conditions during Ramadan fasting
    Finch, GM
    Day, JEL
    Razak
    Welch, DA
    Rogers, PJ
    APPETITE, 1998, 31 (02) : 159 - 170