Stability and marginal bone level measurements of unsplinted implants used for mandibular overdentures: a 1-year randomized prospective clinical study comparing early and conventional loading protocols

被引:78
|
作者
Turkyilmaz, Ilser
Sennerby, Lars
Tumer, Celal
Yenigul, Muhittin
Avci, Mehmet
机构
[1] Gothenburg Univ, Sahlgrenska Acad, Inst Surg Sci, Dept Biomat, SE-40530 Gothenburg, Sweden
[2] Hacettepe Univ, Fac Dent, Dept Prosthodont, Ankara, Turkey
[3] Hacettepe Univ, Fac Dent, Dept Oral & Maxillofacial Surg, Ankara, Turkey
关键词
early loading; mandibular overdentures; marginal bone resorption; resonance frequency analysis;
D O I
10.1111/j.1600-0501.2006.01261.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study was to compare the performance of two non-splinted implants used as retention for a mandibular overdenture when applying conventional or early loading protocols. Materials and methods: Twenty edentulous patients were treated with two unsplinted and non-submerged implants (15 mm long, TiUnite RP, Branemark System) in the anterior mandible. The patients were randomly allotted into two groups: (i) test group (Group A), in which the overdenture was connected 1 week after surgery, and (ii) control group (Group B), in which the overdenture was connected after 12 weeks of healing. Resonance frequency analyses (RFA) for implant stability measurements were performed at implant surgery and after 1, 3, 6, 9 and 12 months. Marginal bone levels were evaluated at implant surgery and after 6 and 12 months. Results: No implant from either group was lost and all implants showed less than 1 mm of marginal bone resorption during the first year. The mean implant stability quotient (ISQ) values at implant surgery were 76.2 +/- 2.8 for Group A and 75.6 +/- 4.5 for Group B. The 12-month measurements showed 76.4 +/- 2.5 ISQ and 76.4 +/- 2.8 ISQ for Groups A and B, respectively. There were no statistically significant changes between or within the groups with time. There were no differences in marginal bone loss, which was on average 0.3 mm for both groups after 1 year. Conclusions: Although a limited number of patients were followed for 1 year only, the results of the present study indicate that early loading of two unsplinted 15 mm long implants with an overdenture does not negatively affect implant stability or marginal bone conditions when compared with implants subjected to 12 weeks of healing before loading.
引用
收藏
页码:501 / 505
页数:5
相关论文
共 50 条
  • [21] Early loading of endosseous implants in the augmented maxilla: a 1-year prospective study
    Raghoebar, GM
    Schoen, P
    Meijer, HJA
    Stellingsma, K
    Vissink, A
    CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (06) : 697 - 702
  • [22] Implant Mandibular Overdentures Retained by Immediately Loaded Implants: A 1-Year Randomized Trial Comparing the Clinical and Radiographic Outcomes Between Mini Dental Implants and Standard-Sized Implants
    Zygogiannis, Kostas
    Aartman, Irene H. A.
    Parsa, Azin
    Tahmaseb, Ali
    Wismeijer, Daniel
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (06) : 1377 - 1388
  • [23] Immediate loading of two unsplinted implants retaining the existing complete mandibular denture in elderly edentulous patients: 1-year results from a multicentre prospective cohort study
    Grandi, Tommaso
    Guazzi, Paolo
    Samarani, Rawad
    Garuti, Giovanna
    Grandi, Giovanni
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2012, 5 (01) : 61 - 68
  • [24] Impact of Platform Switched Implants on Marginal Bone Level in Mandibular Overdentures: A Six-Year Follow-Up Longitudinal Study
    Rahim, Neveen S. Abd El
    Ashour, Asmaa A.
    CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2022, 14 : 307 - 319
  • [25] Immediate Loading of Two Freestanding Implants Retaining a Mandibular Overdenture: 1-Year Pilot Prospective Study
    Liao, Kuo-Yang
    Kan, Joseph Y.
    Rungcharassaeng, Kitichai
    Lozada, Jaime L.
    Herford, Alan S.
    Goodacre, Charles J.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (04) : 784 - 790
  • [26] A Prospective Randomized Study on the Immediate Loading of Mandibular Overdentures Supported by One or Two Implants; A 3 Year Follow-Up Report
    Kronstrom, Mats
    Davis, Ben
    Loney, Robert
    Gerrow, Jack
    Hollender, Lars
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2014, 16 (03) : 323 - 329
  • [27] Clinical performance of narrow-diameter implants with hydrophobic and hydrophilic surfaces with mandibular implant overdentures: 1-year results of a randomized clinical trial
    Bielemann, Amalia Machado
    Schuster, Alessandra Julie
    Possebon, Anna Paula da Rosa
    Schinestsck, Andre Ribeiro
    Chagas-Junior, Otacilio Luiz
    Faot, Fernanda
    CLINICAL ORAL IMPLANTS RESEARCH, 2022, 33 (01) : 21 - 32
  • [28] Resilient Stud Versus Bar Attachments for Immediately Loaded Implants Supporting Mandibular Overdentures: 1-year Randomized Controlled Clinical Trial
    Elsyad, Moustafa Abdou
    Alsabri, Mohammed Abdullah
    Elgamal, Mohamed
    Al-Tonbary, Gilan Youssef
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (02) : 346 - 354
  • [29] Early Loading of Mandibular Molar Single Implants: 1 Year Results of a Randomized Controlled Clinical Trial
    Lee, Jungwon
    Lim, Young-Jun
    Kim, Bongju
    Koo, Ki-Tae
    MATERIALS, 2020, 13 (18)
  • [30] Correlation of implant position and crestal bone loss in 2-implant mandibular overdentures with immediate loading protocols: A prospective clinical study
    Patil, Pravinkumar G.
    Seow, Liang Lin
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (04): : 772 - 779