Wideband 2-D Array Design Optimization With Fabrication Constraints for 3-D US Imaging

被引:37
|
作者
Roux, Emmanuel [1 ,2 ,3 ]
Ramalli, Alessandro [1 ]
Liebgott, Herve [2 ,3 ]
Cachard, Christian [2 ,3 ]
Robini, Marc C. [2 ,3 ]
Tortoli, Piero [1 ]
机构
[1] Univ Florence, Dept Informat Engn, I-50139 Florence, Italy
[2] Univ Lyon, INSA Lyon, CREATIS Lab, F-69007 Lyon, France
[3] Univ Claude Bernard Lyon 1, F-69100 Villeurbanne, France
关键词
COLUMN-ADDRESSED ARRAYS; 3D ULTRASOUND; SYSTEM; TRANSDUCER; ALGORITHM; ELEMENTS; PROBE;
D O I
10.1109/TUFFC.2016.2614776
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasound (US) 2-D arrays are of increasing interest due to their electronic steering capability to investigate 3-D regions without requiring any probe movement. These arrays are typically populated by thousands of elements that, ideally, should be individually driven by the companion scanner. Since this is not convenient, the so-called microbeamforming methods, yielding a prebeamforming stage performed in the probe handle by suitable custom integrated circuits, have so far been implemented in a few commercial high-end scanners. A possible approach to implement relatively cheap and efficient 3-D US imaging systems is using 2-D sparse arrays in which a limited number of elements can be coupled to an equal number of independent transmit/receive channels. In order to obtain US beams with adequate characteristics all over the investigated volume, the layout of such arrays must be carefully designed. This paper provides guidelines to design, by using simulated annealing optimization, 2-D sparse arrays capable of fitting specific applications or fabrication/implementation constraints. In particular, an original energy function based on multidepth 3-D analysis of the beam pattern is also exploited. A tutorial example is given, addressed to find the Ne elements that should be activated in a 2-D fully populated array to yield efficient acoustic radiating performance over the entire volume. The proposed method is applied to a 32x32 array centered at 3 MHz to select the 128, 192, and 256 elements that provide the best acoustic performance. It is shown that the 256-element optimized array yields sidelobe levels even lower (by 5.7 dB) than that of the reference 716-element circular and (by 10.3 dB) than that of the reference 1024-element array.
引用
收藏
页码:108 / 125
页数:18
相关论文
共 50 条
  • [41] Quantification of 3-D field effects during 2-D microwave imaging
    Meaney, PM
    Paulsen, KD
    Geimer, SD
    Haider, SA
    Fanning, MW
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (07) : 708 - 720
  • [42] Efficient Sample Delay Calculation for 2-D and 3-D Ultrasound Imaging
    Ibrahim, Aya
    Hager, Pascal A.
    Bartolini, Andrea
    Angiolini, Federico
    Arditi, Marcel
    Thiran, Jean-Philippe
    Benini, Luca
    De Micheli, Giovanni
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2017, 11 (04) : 815 - 831
  • [43] Polyelectrolytes of 2-D and 3-D polyphenylenes
    Mihov, G
    Bauer, RE
    Tchebotareva, N
    Knoll, W
    Schmidt, M
    Thünemann, AF
    Müllen, K
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2004, 227 : U476 - U476
  • [44] 3-D SINGLETONS AND 2-D CFT
    ARRASHID, AMH
    FRONSDAL, C
    FLATO, M
    INTERNATIONAL JOURNAL OF MODERN PHYSICS A, 1992, 7 (10): : 2193 - 2206
  • [45] 3-D to 2-D recognition with regions
    Jacobs, DW
    Basri, R
    1997 IEEE COMPUTER SOCIETY CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, PROCEEDINGS, 1997, : 547 - 553
  • [46] 2-D and 3-D endoluminal ultrasound
    Liu, JB
    Goldberg, BB
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 : S137 - S139
  • [47] A comparative analysis of 2-D and 3-D simulation for savonius hydrokinetic turbine array
    Chen, Yunrui
    Zhang, Dayu
    Guo, Penghua
    Hu, Qiao
    Li, Jingyin
    OCEAN ENGINEERING, 2024, 295
  • [48] A comparison of 2-D and 3-D FSE imaging in MR of the cervical spine
    Swainson, CJ
    Hutchinson, CE
    Watson, Y
    CLINICAL RADIOLOGY, 1997, 52 (03) : 194 - 197
  • [49] 2-D/3-D switchable displays
    Willemsen, O. H.
    De Zwart, S. T.
    Hiddink, M. G. H.
    Willemsen, Oscar
    JOURNAL OF THE SOCIETY FOR INFORMATION DISPLAY, 2006, 14 (08) : 715 - 722
  • [50] Scattering probes:: From 2-D to 3-D near field imaging
    Moneron, G
    Fragola, A
    Formanek, F
    Williame, L
    Dubois, A
    Aigouy, L
    de Wilde, Y
    Grésillon, S
    Boccara, C
    NANOPHOTONICS: INTEGRATING PHOTOCHEMISTRY, OPTICS AND NANO/BIO MATERIALS STUDIES, 2004, 1 : 139 - 152