Optimal sizing procedure for stand-alone photovoltaic systems by fuzzy logic

被引:6
|
作者
Conti, S
Tina, G
Ragusa, C
机构
[1] Univ Catania, Dip Elettr Elettron & Sistemist, I-95125 Catania, Italy
[2] Politecn Torino, Dip Ingn Elettr Ind, I-10129 Turin, Italy
关键词
D O I
10.1115/1.1433476
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper an automatic procedure to perform the optimal sizing of a stand-alone solar electrical system with battery storage is developed by a fuzzy logic based multi-objective optimization approach. The procedure aims at finding the configuration that yields the best compromise for the two considered objectives: the long-term average performance and the overall cost of the generating system. In particular, the objectives of the optimization problem are: the maximization of the Supplied Load Fraction, that is the fraction of the actual electrical load that can be supplied by the system, and the minimization of the Relative Unit Electricity Cost, that is the net cost of generating each kWh during the lifetime of the stand-alone solar electrical system referred to the UEC calculated in case of loads supplied by the grid. The control variables are the solar cell array surface, the tilt angle of the modules, and the storage system capacity. The fuzzy multi-objective optimization procedure is described and the application results are presented considering different configurations characterized by some parameters, such as the electrical load, the yearly power demand, the distance from the utility grid, and the solar cells unit cost.
引用
收藏
页码:77 / 82
页数:6
相关论文
共 50 条
  • [31] Development of stand-alone photovoltaic systems
    Glasnovic, Zvonimir
    Urli, Natko
    Etlinger, Bozidar
    ENERGY AND THE ENVIRONMENT 2002, VOL II, 2002, : 255 - 263
  • [32] Accurate Sizing of Residential Stand-Alone Photovoltaic Systems Considering System Reliability
    Quiles, Eduardo
    Roldan-Blay, Carlos
    Escriva-Escriva, Guillermo
    Roldán-Porta, Carlos
    SUSTAINABILITY, 2020, 12 (03)
  • [33] Sizing of stand-alone photovoltaic systems using neural network adaptive model
    Mellit, Adel
    Benghanem, Mohamed
    DESALINATION, 2007, 209 (1-3) : 64 - 72
  • [34] Sizing optimisation of stand-alone photovoltaic generators for irrigation water pumping systems
    El-Shimy, M.
    INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2013, 32 (05) : 333 - 350
  • [35] Optimal sizing of stand-alone photovoltaic system by minimizing the loss of power supply probability
    Aziz, Nur Izzati Abdul
    Sulaiman, Shahril Irwan
    Shaari, Sulaiman
    Musirin, Ismail
    Sopian, Kamaruzzaman
    SOLAR ENERGY, 2017, 150 : 220 - 228
  • [36] Optimal sizing of stand-alone hybrid photovoltaic/wind system using BAT algorithm
    Marsa, Nadia
    Houcine, Lassad
    Zaafouri, Abdurrahman
    Chaari, Abdelkader
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2021, 42 (08) : 920 - 928
  • [37] Fuzzy Logic Energy Management Between Stand-Alone PV Systems
    Ben Ammar, Mohsen
    Zdiri, Mohamed Ali
    Ben Ammar, Rim
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2021, 11 (03): : 1238 - 1249
  • [38] Jaya Learning-Based Optimization for Optimal Sizing of Stand-Alone Photovoltaic, Wind Turbine, and Battery Systems
    Khan, Asif
    Javaid, Nadeem
    ENGINEERING, 2020, 6 (07) : 812 - 826
  • [39] Sizing and Parametric Analysis of a Stand-Alone Photovoltaic Power Plant
    Nikhil, P. G.
    Subhakar, D.
    IEEE JOURNAL OF PHOTOVOLTAICS, 2013, 3 (02): : 776 - 784
  • [40] Optimal Sizing Stand-alone PV Systems in Terms of Extreme Value Theory
    Chen, Shin-Guang
    TENCON 2009 - 2009 IEEE REGION 10 CONFERENCE, VOLS 1-4, 2009, : 176 - 181