Predictors of paravalvular regurgitation and permanent pacemaker implantation after TAVR with a next-generation self-expanding device

被引:38
|
作者
Mauri, Victor [1 ]
Deuschl, Florian [2 ]
Frohn, Thomas [1 ]
Schofer, Niklas [2 ]
Linder, Matthias [3 ]
Kuhn, Elmar [4 ]
Schaefer, Andreas [3 ]
Rudolph, Volker [1 ]
Madershahian, Navid [4 ]
Conradi, Lenard [3 ]
Rudolph, Tanja K. [1 ]
Schaefer, Ulrich [2 ]
机构
[1] Univ Cologne, Dept Cardiol, Heart Ctr, Kerpener Str 62, D-50937 Cologne, Germany
[2] Univ Heart Ctr Hamburg, Dept Gen & Intervent Cardiol, Martinistr 52, D-20246 Hamburg, Germany
[3] Univ Heart Ctr Hamburg, Dept Cardiovasc Surg, Hamburg, Germany
[4] Univ Cologne, Heart Ctr, Dept Cardiothorac Surg, Cologne, Germany
关键词
Transcatheter aortic valve replacement; Permanent pacemaker implantation; Paravalvular regurgitation; Prediction of risk; ACURATE neo TF; Calcium distribution; AORTIC-VALVE-REPLACEMENT; LANDING ZONE CALCIFICATION; EDWARDS SAPIEN; TRANSCATHETER; OUTCOMES; SEVERITY; LOCATION; CALCIUM; SYSTEM; IMPACT;
D O I
10.1007/s00392-018-1235-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To identify predictors of paravalvular regurgitation (PVR) and permanent pacemaker implantation (PPI) following TAVR with a next-generation self-expanding device. Device landing zone (DLZ) calcification, angiographic implantation depth, and baseline and procedural characteristics were analyzed in 212 patients being treated with the ACURATE neo aortic bioprosthesis. PVR was none/trace in 57.1% and mild in 42.9% (37% mild, 6% moderate). DLZ calcification (705 (IQR 240-624) vs. 382 (IQR 240-624) mm(3); P < 0.001) as well as absolute calcium asymmetry (233 +/- 159 vs. 151 +/- 151 mm(3); P < 0.001) was significantly higher in patients with PVR mild. On multivariate analysis, calcification of the aortic valve cusps (AVC) > 410.6 mm(3) was independently associated with PVR mild. PPI rate was 10.3% (n = 20). Patients with and without need for PPI had similar total DLZ calcium volume (740 (IQR 378-920) vs. 536 (IQR 315-822) mm(3); P = 0.263), but exhibited different calcium distribution patterns: LVOT calcium > 41.4 mm(3) in the sector below the left coronary cusp (LVOTLC) was associated with increased PPI risk (26.9 vs. 7.7%; P = 0.008). The quantity of AVC calcium predicts residual PVR. Multivariable analysis identified LVOTLC calcium, pre-existing RBBB, and age > 82.7 years as independent predictors of PPI. Based on these risk factors, a patient's individual PPI risk can be stratified ranging from 3.8 to 100%.
引用
收藏
页码:688 / 697
页数:10
相关论文
共 50 条
  • [21] Pacing Burden in Those Undergoing Permanent Pacemaker Implantation After TAVR With Latest Generation Valves
    Sandhu, Amneet
    Ream, Karen
    Tzou, Wendy
    Tumolo, Alexis
    Fleeman, Blake
    Mantini, Nicholas
    Nguyen, Duy T.
    Sauer, William H.
    Aleong, Ryan G.
    CIRCULATION, 2018, 138
  • [22] Paravalvular regurgitation after transcatheter aortic valve implantation with self-expanding prosthesis: short-term evolution and long term prognostic impact
    Ruiz Ortiz, M.
    Delgado, M.
    Mesa, D.
    Fernandez Cabeza, J.
    Aristizabal, C.
    Gutierrez Ballesteros, G.
    Martin Hidalgo, M.
    Sanchez Fernandez, J.
    Duran, E.
    Ferreiro, C.
    Mazuelos, F.
    De Tejada, J. Suarez De Lezo Herreros
    Segura, J.
    Pan, M.
    Suarez De Lezo, J.
    EUROPEAN HEART JOURNAL, 2016, 37 : 462 - 462
  • [23] Permanent pacemaker implantation and left bundle branch block with self-expanding valves - a SCOPE 2 subanalysis
    Pellegrini, Costanza
    Garot, Philippe
    Morice, Marie-Claude
    Tamburino, Corrado
    Bleiziffer, Sabine
    Thiele, Holger
    Scholtz, Smita
    Schramm, Rene
    Cockburn, James
    Cunnington, Michael
    Wolf, Alexander
    Barbanti, Marco
    Tchetche, Didier
    Pagnotta, Paolo
    Gilard, Martine
    Bedogni, Francesco
    Van Belle, Eric
    Vasa-Nicotera, Mariuca
    Chieffo, Alaide
    Bogaerts, Kris
    Hengstenberg, Christian
    Capodanno, Davide
    Joner, Michael
    Neumann, Franz-Josef
    EUROINTERVENTION, 2023, 18 (13) : E1077 - +
  • [24] Predictors for Paravalvular Regurgitation After Transcatheter Aortic Valve Replacement With the Self-Expanding CoreValve Prosthesis: Quantitative Measurement of Multidetector Computed Tomographic Analysis
    Yoon, Sung-Han
    Ohno, Yohei
    Barbanti, Marco
    Ahn, Jung-Min
    Chan, Jason Leung Kwai
    Lin, Mao-Shin
    Kim, Young-Hak
    Yang, Dong Hyun
    Imme, Sebastiano
    Tamburino, Claudia
    Sgroi, Carmelo
    Park, Duk-Woo
    Kang, Soo-Jin
    Lee, Seung-Whan
    Lee, Cheol Whan
    Park, Seong-Wook
    Chan, Kam-Tim
    Lee, Michael K.
    Kao, Paul Hsien-Li
    Tamburino, Corrado
    Park, Seung-Jung
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B259 - B259
  • [25] New insights on potential permanent pacemaker predictors in TAVR using the largest self-expandable device
    Veulemans, Verena
    Frank, Derk
    Seoudy, Hatim
    Wundram, Steffen
    Piayda, Kerstin
    Maier, Oliver
    Jung, Christian
    Polzin, Amin
    Frey, Norbert
    Kelm, Malte
    Zeus, Tobias
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2020, 10 (06) : 1816 - +
  • [26] Percutaneous treatment of paravalvular leaks after transcatheter aortic valve implantation with the CoreValve self-expanding bioprosthesis
    Saia, Francesco
    Marrozzini, Cinzia
    Moretti, Carolina
    Bordoni, Barbara
    Ciuca, Cristina
    Marzocchi, Antonio
    EUROINTERVENTION, 2013, 9 (02) : 292 - 292
  • [27] AORTIC VALVE CALCIFICATION PREDICTS PARAVALVULAR AORTIC REGURGITATION AFTER SELF-EXPANDING TRANSCATHETER AORTIC VALVE REPLACEMENT
    Agha, Ahmad
    Ali, Nisreen
    Memon, Shermeen
    Bakhos, Lara
    Dajani, Khaled
    Rabbat, Mark
    Leya, Ferdinand
    Syed, Mushabbar
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 1506 - 1506
  • [28] Impact of device landing zone calcification patterns on paravalvular regurgitation after transcatheter aortic valve replacement with different next-generation devices
    Mauri, Victor
    Frohn, Thomas
    Deuschl, Florian
    Mohemed, Kawa
    Kuhr, Kathrin
    Reimann, Andreas
    Koerber, Maria Isabel
    Schofer, Niklas
    Adam, Matti
    Friedrichs, Kai
    Kuhn, Elmar W.
    Scholtz, Smita
    Rudolph, Volker
    Wahlers, Thorsten C. W.
    Baldus, Stephan
    Mader, Navid
    Schafer, Ulrich
    Rudolph, Tanja K.
    OPEN HEART, 2020, 7 (01):
  • [29] Pacemaker dependency after transcatheter aortic valve implantation with the self-expanding Medtronic CoreValve System
    van der Boon, Robert M. A.
    Van Mieghem, Nicolas M.
    Theuns, Dominic A.
    Nuis, Rutger-Jan
    Nauta, Sjoerd T.
    Serruys, Patrick W.
    Jordaens, Luc
    van Domburg, Ron T.
    de Jaegere, Peter P. T.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (02) : 1269 - 1273
  • [30] Small balloon strategy associated with low pacemaker implantation rate after self-expanding transcatheter valve implantation
    Yuan Zhang
    Wen-zhi Pan
    Li-hua Guan
    Xiao-chun Zhang
    Sha-sha Chen
    Li-fan Yang
    Lei Zhang
    Ming-fei Li
    Dan-dan Chen
    Da-xin Zhou
    Jun-bo Ge
    World Journal of Emergency Medicine, 2021, 12 (01) : 48 - 53