An ultra-sensitive and wideband magnetometer based on a superconducting quantum interference device

被引:78
|
作者
Storm, Jan-Hendrik [1 ]
Hoemmen, Peter [1 ]
Drung, Dietmar [1 ]
Koerber, Rainer [1 ]
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
关键词
TO-NOISE RATIO; MRI; FIELDS;
D O I
10.1063/1.4976823
中图分类号
O59 [应用物理学];
学科分类号
摘要
The magnetic field noise in superconducting quantum interference devices (SQUIDs) used for biomagnetic research such as magnetoencephalography or ultra-low-field nuclear magnetic resonance is usually limited by instrumental dewar noise. We constructed a wideband, ultra-low noise system with a 45 mm diameter superconducting pick-up coil inductively coupled to a current sensor SQUID. Thermal noise in the liquid helium dewar is minimized by using aluminized polyester fabric as superinsulation and aluminum oxide strips as heat shields. With a magnetometer pickup coil in the center of the Berlin magnetically shielded room 2 (BMSR2), a noise level of around 150 aT Hz(-1/2) is achieved in the white noise regime between about 20 kHz and the system bandwidth of about 2.5 MHz. At lower frequencies, the resolution is limited by magnetic field noise arising from the walls of the shielded room. Modeling the BMSR2 as a closed cube with continuous l-metal walls, we can quantitatively reproduce its measured field noise. Published by AIP Publishing.
引用
收藏
页数:4
相关论文
共 50 条
  • [22] Characterization of directly coupled dual-superconducting quantum interference device magnetometer
    Wu, C. H.
    Chen, J. H.
    Jhan, F. J.
    Jeng, J. T.
    Yang, H. C.
    JOURNAL OF APPLIED PHYSICS, 2008, 104 (07)
  • [23] Ultra-sensitive Magnetic Microscopy with an Optically Pumped Magnetometer
    Young Jin Kim
    Igor Savukov
    Scientific Reports, 6
  • [24] Development of miniature diamond anvil cell for the superconducting quantum interference device magnetometer
    Mito, M
    Hitaka, M
    Kawae, T
    Takeda, K
    Kitai, T
    Toyoshima, N
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2001, 40 (11): : 6641 - 6644
  • [25] Improved superconducting quantum interference device magnetometer for low cross talk operation
    Granata, C.
    Vettoliere, A.
    Russo, M.
    APPLIED PHYSICS LETTERS, 2006, 88 (21)
  • [26] Design and fabrication of low-noise superconducting quantum interference device magnetometer
    Han Hao-Xuan
    Zhang Guo-Feng
    Zhang Xue
    Liang Tian-Tian
    Ying Li-Liang
    Wang Yong-Liang
    Peng Wei
    Wang Zhen
    ACTA PHYSICA SINICA, 2019, 68 (13)
  • [27] An absolute magnetometer based on dc Superconducting QUantum Interference Devices
    Carelli, P
    Castellano, MG
    Flacco, K
    Leoni, R
    Torrioli, G
    EUROPHYSICS LETTERS, 1997, 39 (05): : 569 - 574
  • [28] Ultra-sensitive Magnetic Microscopy with an Optically Pumped Magnetometer
    Kim, Young Jin
    Savukov, Igor
    SCIENTIFIC REPORTS, 2016, 6
  • [29] Experimental study of a hybrid single flux quantum digital superconducting quantum interference device magnetometer
    Reich, Torsten
    Febvre, Pascal
    Ortlepp, Thomas
    Uhlmann, F. Hermann
    Kunert, Juergen
    Stolz, Ronny
    Meyer, Hans-Georg
    JOURNAL OF APPLIED PHYSICS, 2008, 104 (02)
  • [30] Experimental study of a hybrid single flux quantum digital superconducting quantum interference device magnetometer
    Reich, Torsten
    Febvre, Pascal
    Ortlepp, Thomas
    Uhlmann, F. Hermann
    Kunert, Juergen
    Stolz, Ronny
    Meyer, Hans-Georg
    Journal of Applied Physics, 2008, 104 (02):