An ultra-sensitive and wideband magnetometer based on a superconducting quantum interference device

被引:78
|
作者
Storm, Jan-Hendrik [1 ]
Hoemmen, Peter [1 ]
Drung, Dietmar [1 ]
Koerber, Rainer [1 ]
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
关键词
TO-NOISE RATIO; MRI; FIELDS;
D O I
10.1063/1.4976823
中图分类号
O59 [应用物理学];
学科分类号
摘要
The magnetic field noise in superconducting quantum interference devices (SQUIDs) used for biomagnetic research such as magnetoencephalography or ultra-low-field nuclear magnetic resonance is usually limited by instrumental dewar noise. We constructed a wideband, ultra-low noise system with a 45 mm diameter superconducting pick-up coil inductively coupled to a current sensor SQUID. Thermal noise in the liquid helium dewar is minimized by using aluminized polyester fabric as superinsulation and aluminum oxide strips as heat shields. With a magnetometer pickup coil in the center of the Berlin magnetically shielded room 2 (BMSR2), a noise level of around 150 aT Hz(-1/2) is achieved in the white noise regime between about 20 kHz and the system bandwidth of about 2.5 MHz. At lower frequencies, the resolution is limited by magnetic field noise arising from the walls of the shielded room. Modeling the BMSR2 as a closed cube with continuous l-metal walls, we can quantitatively reproduce its measured field noise. Published by AIP Publishing.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Highly Sensitive Tunable Magnetometer Based on Superconducting Quantum Interference Device
    Vettoliere, Antonio
    Granata, Carmine
    SENSORS, 2023, 23 (07)
  • [2] An ultra high sensitive current sensor based on Superconducting Quantum Interference Device
    Vettoliere, A.
    Granata, C.
    Russo, M.
    SUPERCONDUCTIVITY CENTENNIAL CONFERENCE 2011, 2012, 36 : 25 - 28
  • [3] Calibration of a superconducting quantum interference device magnetometer
    Koyano, T., 1600, Japan Society of Applied Physics (43):
  • [4] Calibration of a superconducting quantum interference device magnetometer
    Koyano, T
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2004, 43 (10): : 7322 - 7323
  • [5] A miniature magnetometer based on the superconducting quantum interference device with direct readout electronics
    Polushkin, V
    Wallis, M
    Glowacka, D
    Matthews, A
    Lumley, JM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (03): : 1461 - 1464
  • [6] Broadband Ultra-sensitive Adiabatic Magnetometer
    Savukov, Igor
    Kim, Young Jin
    2021 IEEE SENSORS APPLICATIONS SYMPOSIUM (SAS 2021), 2021,
  • [7] AN 8-T SUPERCONDUCTING QUANTUM INTERFERENCE DEVICE MAGNETOMETER
    GENNA, JC
    BISTON, S
    COTILLARD, JC
    LETHUILLIER, P
    FAURIN, C
    HOSTACHY, P
    ROCCAVALERO, R
    ROULLIER, J
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (07): : 1824 - 1827
  • [8] KEY ELEMENTS FOR A SENSITIVE 77 M DIRECT-CURRENT SUPERCONDUCTING QUANTUM INTERFERENCE DEVICE MAGNETOMETER
    LEE, LP
    TEEPE, M
    VINETSKIY, V
    CANTOR, R
    COLCLOUGH, MS
    APPLIED PHYSICS LETTERS, 1995, 66 (22) : 3059 - 3061
  • [9] Ultra-Sensitive Vector Magnetometer for Magnetocardiographic Mapping
    Gusev N.A.
    Vetoshko P.M.
    Kuzmichev A.N.
    Chepurnova D.A.
    Samoilova E.V.
    Zvezdin A.K.
    Korotaeva A.A.
    Belotelov V.I.
    Gusev, N.A. (nagusew@gmail.com), 1600, Springer Science and Business Media, LLC (51): : 157 - 161
  • [10] High Sensitive Magnetic Nanosensors Based on Superconducting Quantum Interference Device
    Esposito, Emanuela
    Granata, Carmine
    Russo, Maurizio
    Russo, Roberto
    Vettoliere, Antonio
    IEEE TRANSACTIONS ON MAGNETICS, 2013, 49 (01) : 140 - 143