Experimental and Numerical Testing of Heat Pump Evaporator

被引:4
|
作者
Santa, Robert [1 ]
Bosnjakovic, Mladen [2 ]
Cikic, Ante [3 ]
机构
[1] Univ Dunaujvar, Tancs Mihaly 1-A, H-2400 Dunaujvaros, Hungary
[2] Univ Slavonski Brod, Tech Dept, Trg Ivane Brlic Mazuranic 2, Slavonski Brod 35000, Croatia
[3] Univ North, Dept Mech Engn, 104 Brigade 3, Varazhdin 42000, Croatia
来源
APPLIED SCIENCES-BASEL | 2022年 / 12卷 / 23期
关键词
evaporator mathematical model; shell and tube evaporator; numerical and experimental testing; STEADY-STATE; MATHEMATICAL-MODEL; DYNAMIC SIMULATION; R134A;
D O I
10.3390/app122311973
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
When designing a heat pump evaporator, it is necessary to use correlations that ensure small deviations of the designed and realized process parameters for specific input data. The aim of the work is to propose a suitable mathematical model for the physical process in the tubular evaporator of the heat pump. The applicability of the proposed mathematical model in the design of the heat pump was evaluated by comparing the results obtained from the experimental tests of the tubular evaporator of the heat pump with the numerical results obtained from the application of the proposed mathematical model. For the experimental tests, a tubular evaporator was made and 10 measuring points were set up, where the process parameters were measured (temperature and pressure drop of the working media R134a and water). Theoretical results were obtained by dividing the evaporator into control volumes and solving the corresponding system of equations of the proposed mathematical model using the Runge-Kutta and Adams Moulton predictor-corrector method. As an independent parameter, the water temperature at the inlet to the evaporator was varied in the range of 10 degrees C to 18 degrees C. The test results show that the largest deviation of the calculated and measured water temperature is +0.41 degrees C to -0.58 degrees C, while the refrigerant temperature is +0.43 degrees C to + 0.52 degrees C. The largest deviation of the evaporator thermal capacity based on the calculations and experimental tests is +9.39% to -6.31%. Based on the obtained results, it is possible to recommend the use of the proposed mathematical model for the design of the tubular evaporator of a heat pump.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Numerical analysis and experimental study on the performance optimization of cold storage heat exchanger integrated with evaporator
    Daewoong Lee
    International Journal of Automotive Technology, 2017, 18 : 377 - 385
  • [42] Heat transmission in an experimental inclined tube evaporator
    Linden, CM
    Montillon, GH
    TRANSACTIONS OF THE AMERICAN INSTITUTE OF CHEMICAL ENGINEERS, 1930, 24 : 120 - 141
  • [43] Heat transmission in an experimental inclined tube evaporator
    Linden, CM
    Montillon, GH
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1930, 22 : 708 - 713
  • [44] An experimental comparison of two heat exchangers used in wastewater source heat pump: A novel dry-expansion shell-and-tube evaporator versus a conventional immersed evaporator
    Shen, Chao
    Jiang, Yiqiang
    Yao, Yang
    Wang, Xinlei
    ENERGY, 2012, 47 (01) : 600 - 608
  • [45] Measurement testing of heat transfer coefficients in the evaporator and condenser of heat pumps
    Santa, Robert
    Garbai, Laszlo
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2015, 119 (03) : 2099 - 2106
  • [46] Measurement testing of heat transfer coefficients in the evaporator and condenser of heat pumps
    Róbert Sánta
    László Garbai
    Journal of Thermal Analysis and Calorimetry, 2015, 119 : 2099 - 2106
  • [47] Numerical modelling of photovoltaic thermal evaporator for heat pumps
    Aliuly, A.
    Mohanraj, M.
    Belyayev, Ye.
    Jayaraj, S.
    Kaltayev, A.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2016, 48 : 135 - 139
  • [48] Numerical Analysis of the Evaporator for Cryogenic Looped Heat Pipe
    Park, Jaehyun
    Park, Heesung
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2019, 43 (03) : 169 - 174
  • [49] Experimental performance evaluation of a novel dry-expansion evaporator with defouling function in a wastewater source heat pump
    Shen Chao
    Jiang Yiqiang
    Yao Yang
    Deng Shiming
    APPLIED ENERGY, 2012, 95 : 202 - 209
  • [50] Distributed dynamic modeling and experimental study of PV evaporator in a PV/T solar-assisted heat pump
    Ji, Jie
    He, Hanfeng
    Chow, Tintai
    Pei, Gang
    He, Wei
    Liu, Keliang
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (5-6) : 1365 - 1373