Sensitive voltammetric determination of testosterone in pharmaceuticals and human urine using a glassy carbon electrode in the presence of cationic surfactant

被引:48
|
作者
Levent, Abdulkadir [1 ]
Altun, Ahmet [1 ]
Yardim, Yavuz [2 ]
Senturk, Zuhre [3 ]
机构
[1] Batman Univ, Hlth Serv Vocat Coll, TR-72100 Batman, Turkey
[2] Yuzuncu Yil Univ, Dept Analyt Chem, Fac Pharm, TR-65080 Van, Turkey
[3] Yuzuncu Yil Univ, Dept Analyt Chem, Fac Sci, TR-65080 Van, Turkey
关键词
Testosterone; Glassy carbon electrode; Cetyltrimethylammonium bromide; Square-wave adsorptive stripping voltammetry; TANDEM MASS-SPECTROMETRY; ADSORPTIVE STRIPPING VOLTAMMETRY; DOPED DIAMOND ELECTRODE; SODIUM DODECYL-SULFATE; LIQUID-CHROMATOGRAPHY; ANIONIC SURFACTANT; ELECTROCHEMICAL IMMUNOSENSOR; GRAPHITE ELECTRODE; ANABOLIC-STEROIDS; EPITESTOSTERONE;
D O I
10.1016/j.electacta.2013.10.024
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this work, the electrochemical investigation of testosterone, a steroid hormone from the androgen group, was carried out in aqueous and aqueous/surfactant solutions using a glassy carbon (GC) electrode. In cyclic voltammetry, the compound showed one irreversible and adsorption-controlled reduction peak. Addition of cationic surfactant (cetyltrimethylammonium bromide, CTAB) was found to enhance the reduction current signal of testosterone, whereas, anionic (sodium dodecylsulfate, SDS) and non-ionic (Tween 80) surfactants exhibited opposite effect. Using square-wave adsorptive stripping voltammetry, the current showed a linear dependence with concentration in the range between 10 and 70 nM in Britton-Robinson buffer, pH 5.0 containing 3 mM CTAB. A detection limit of 1.18 nM (0.34 ng mL(-1)), and relative standard deviation of 4.12% for a concentration level of 35 nM (n = 11) were calculated. This method was successfully applied for the analysis of testosterone in oil-based pharmaceutical preparations and urine samples without any separation. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:54 / 60
页数:7
相关论文
共 50 条
  • [31] Voltammetric determination of acetaminophen in pharmaceutical preparations and human urine using glassy carbon paste electrode modified with reduced graphene oxide
    Amir Shaaban Farag
    Analytical Sciences, 2022, 38 : 1213 - 1220
  • [32] Voltammetric determination of tert-butylhydroquinone in biodiesel using a carbon paste electrode in the presence of surfactant
    de Araujo, Tatiane Alfonso
    Jacques Barbosa, Antonio Marcos
    Viana, Luiz Henrique
    Ferreira, Valdir Souza
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2010, 79 (02) : 409 - 414
  • [33] VOLTAMMETRIC QUANTITATIVE ANALYSIS OF INDIGO IN WATER AND URINE USING GLASSY CARBON ELECTRODE
    Matoetoe, Mangaka C.
    Ramokepa, Batloung
    Iwuoha, Emmanuel I.
    ANALYTICAL LETTERS, 2011, 44 (11) : 1879 - 1890
  • [34] Voltammetric Determination of Acyclovir in Human Urine Using Ultra Trace Graphite and Glassy Carbon Electrodes
    Sadikoglu, Murat
    Saglikoglu, Gulsen
    Yagmur, Sultan
    Orta, Erdem
    Yilmaz, Selehattin
    CURRENT ANALYTICAL CHEMISTRY, 2011, 7 (02) : 130 - 135
  • [35] Design of a Sensitive and Selective Voltammetric Sensor Based on a Cationic Surfactant-Modified Carbon Paste Electrode for the Determination of Alloxan
    Monnappa, Amrutha B.
    Manjunatha, Jamballi G.
    Bhatt, Aarti S.
    ACS OMEGA, 2020, 5 (36): : 23481 - 23490
  • [36] VOLTAMMETRIC DETERMINATION OF TOTAL ALKANNIN USING A GLASSY-CARBON ELECTRODE
    CHAISUKSANT, R
    VOULGAROPOULOS, A
    MELLIDIS, AS
    PAPAGEORGIOU, VP
    ANALYST, 1993, 118 (02) : 179 - 182
  • [37] Voltammetric Determination of Epinephrine using a Thiourea Modified Glassy Carbon Electrode
    Yazdely, Malihe Ahmadian
    Taher, Mohammad Ali
    Tajik, Somayeh
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2013, 5 (04): : 517 - 527
  • [38] Sensitive voltammetric determination of rutin in pharmaceuticals, human serum, and traditional Chinese medicines using a glassy carbon electrode coated with graphene nanosheets, chitosan, and a poly(amido amine) dendrimer
    Huanshun Yin
    Yunlei Zhou
    Lin Cui
    Tao Liu
    Peng Ju
    Lusheng Zhu
    Shiyun Ai
    Microchimica Acta, 2011, 173 : 337 - 345
  • [39] Sensitive voltammetric determination of rutin in pharmaceuticals, human serum, and traditional Chinese medicines using a glassy carbon electrode coated with graphene nanosheets, chitosan, and a poly(amido amine) dendrimer
    Yin, Huanshun
    Zhou, Yunlei
    Cui, Lin
    Liu, Tao
    Ju, Peng
    Zhu, Lusheng
    Ai, Shiyun
    MICROCHIMICA ACTA, 2011, 173 (3-4) : 337 - 345
  • [40] APPLICATION OF GLASSY CARBON ELECTRODE MODIFIED WITH NAFION/MWCNTS FOR SENSITIVE VOLTAMMETRIC DETERMINATION OF THYMOL
    Piech, Robert
    Paczosa-Bator, Beata
    ACTA POLONIAE PHARMACEUTICA, 2015, 72 (06): : 1081 - 1088