Application of real-time shear wave elastography in the assessment of torsional cervical dystonia

被引:8
|
作者
Song, Ye [1 ]
Zhang, Tian-Jie [2 ]
Li, Yuan [1 ]
Gao, Yuan [3 ]
机构
[1] Shanghai Univ Med & Hlth Sci, Coll Med Imaging, Zhoupu Hosp, Dept Ultrasonog, Shanghai 201318, Peoples R China
[2] Shanghai Huapukang Pediat Clin, Shanghai 310105, Peoples R China
[3] Tongji Univ, Dept Surg, Tongji Hosp, Shanghai 200065, Peoples R China
关键词
Shear wave elastography; real-time; torsional cervical dystonia; skeletal muscle; shear elastic modulus; PASSIVE MUSCLE-STIFFNESS; QUANTITATIVE ASSESSMENT; BOTULINUM TOXIN; RELIABILITY; CHILDREN; HARDNESS;
D O I
10.21037/qims.2019.04.08
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: This study aimed to investigate the value of real-time shear wave elastography (SWE) in the assessment of torsional cervical dystonia (TCD). Methods: Ninety healthy volunteers and 30 TCD patients were recruited, and elastography was performed at musculi sternocleidomastoideus (MSD) and musculi splenius capitis (MSC). Mean shear elastic modulus of right MSD and MSC in healthy controls and bilateral MSD and MSC in TCD patients was determined. The thickness of MSD and MSC of affected muscles was measured in TCD patients. Results: In TCD patients, the mean shear elastic modulus of affected MSD and MSC was significantly higher than that of corresponding normal muscles (P<0.01) and that of controls (P<0.01). The diagnostic threshold was 24.9 kPa for MSD and 25.07 kPa for MSC (for MSD and MSC, the area under ROC was 0.979 and 0.979, with a sensitivity of 90% and 91.3%, and a specificity of 95.6% and 96.7%, respectively). The elastic modulus of neither affected nor normal MSD and MSC was significantly related to age and body mass index (P>0.05). The shear elastic modulus of affected MSD and MSC was positively related to the peak electromyography (r=0.83-0.73, P<0.01). The thickness of affected MSD and MSC was significantly thicker than that of corresponding normal muscles in TCD patients (P<0.01). Conclusions: Real-time SWE can identify the difference in shear elastic modulus of MSD and MSC between the affected and normal side in TCD patients, indicating important diagnostic value in the assessment of muscular status for these patients.
引用
收藏
页码:662 / 670
页数:9
相关论文
共 50 条
  • [11] INFLUENCE OF MEASUREMENT DEPTH ON THE STIFFNESS ASSESSMENT OF HEALTHY LIVER WITH REAL-TIME SHEAR WAVE ELASTOGRAPHY
    Wang, Cong-Zhi
    Zheng, Jian
    Huang, Ze-Ping
    Xiao, Yang
    Song, Dan
    Zeng, Jie
    Zheng, Hai-Rong
    Zheng, Rong-Qin
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (03): : 461 - 469
  • [12] Clinical Application of Real-Time Shear Wave Elastography in Identifying the Histological Components of Parotid Adenolymphoma
    Huang, Kun
    Gao, Ningning
    Wang, Xuemei
    Bian, Donglin
    Liu, Yanjun
    Zhai, Qixi
    ULTRASOUND QUARTERLY, 2018, 34 (02) : 47 - 51
  • [13] Application value of real-time shear wave elastography in the diagnosis and efficacy evaluation of venous thrombosis
    Wu, Jing
    Yang, Xiaoyan
    Liu, Yun
    Xi, Fang
    Lei, Ping
    TECHNOLOGY AND HEALTH CARE, 2024, 32 (05) : 3513 - 3523
  • [14] The value of real-time shear wave elastography in spontaneous preterm birth
    Lu, Huiling
    Liu, Yang
    Yang, Fangrui
    Wu, Dan
    Qi, Jiarui
    Ji, Yonghao
    Hu, Mengli
    MEDICINE, 2024, 103 (33)
  • [15] Transvaginal Real-Time Shear Wave Elastography in the Diagnosis of Endometrial Lesions
    Du, Yuan-Yuan
    Yan, Xiao-Jing
    Guo, Yan-Jing
    Wang, Jing
    Wen, Xiao-Duo
    Wang, Nan
    Yang, Yi
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2021, 14 : 2849 - 2856
  • [16] Reproducibility of real-time shear wave elastography in the evaluation of liver elasticity
    Ferraioli, Giovanna
    Tinelli, Carmine
    Zicchetti, Mabel
    Above, Elisabetta
    Poma, Gianluigi
    Di Gregorio, Marta
    Filice, Carlo
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (11) : 3102 - 3106
  • [17] Shear wave elastography versus real-time elastography on evaluation thyroid nodules: A preliminary study
    Liu, Bao-Xian
    Xie, Xiao-Yan
    Liang, Jin-Yu
    Zheng, Yan-Ling
    Huang, Guang-Liang
    Zhou, Lu-Yao
    Wang, Zhu
    Xu, Ming
    Lu, Ming-De
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (07) : 1135 - 1143
  • [18] Real-time ultrasound elastography: an assessment of enlarged cervical lymph nodes
    Wu-Chia Lo
    Po-Wen Cheng
    Chi-Te Wang
    Li-Jen Liao
    European Radiology, 2013, 23 : 2351 - 2357
  • [19] Utility of Real-Time Shear Wave Elastography in the Assessment of Liver Fibrosis in Patients with Chronic Liver Disease
    Numao, Hiroshi
    Shimaya, Kohji
    Kakuta, Akihisa
    Hasui, Keisuke
    Shibutani, Koichi
    HEPATOLOGY, 2016, 64 : 213A - 213A
  • [20] Real-time ultrasound elastography: an assessment of enlarged cervical lymph nodes
    Lo, Wu-Chia
    Cheng, Po-Wen
    Wang, Chi-Te
    Liao, Li-Jen
    EUROPEAN RADIOLOGY, 2013, 23 (09) : 2351 - 2357