Performance analysis of tower solar aided coal-fired power plant with thermal energy storage

被引:18
|
作者
Jiang, Yue [1 ]
Duan, Liqiang [1 ]
Yang, Ming [1 ]
Tong, Yongjing [1 ]
Pang, Liping [1 ]
机构
[1] North China Elect Power Univ, Key Lab Power Stn Energy Transfer Convers & Syst, Natl Thermal Power Engn & Technol Res Ctr, Sch Energy Power & Mech Engn,Minist Educ, Beijing 102206, Peoples R China
基金
中国国家自然科学基金;
关键词
Solar tower; Thermal energy storage; Double reheat ultra-supercritical unit; Economic analysis; Carbon emission reduction; DOUBLE-SOURCE BOILER; GENERATION SYSTEM; OPTIMIZATION; OPERATION; EXERGY; MODES; HEAT; SAPG;
D O I
10.1016/j.applthermaleng.2022.118101
中图分类号
O414.1 [热力学];
学科分类号
摘要
A novel tower solar aided coal-fired power generation (TSACPG) system with thermal energy storage is proposed in this paper. Based on the principle of energy grade matching and cascade utilization, the high-temperature solar energy is used to heat the first and second reheat steam extracted from the boiler and the low temperature solar energy is used to heat the boiler feed water. The maximum steam extraction mass flow rates of the boiler under different load rates are obtained and the thermal performances are also analyzed. The results show that the maximum steam extraction mass flow rates from the first and second reheat part of boiler are 69.7 kg/s and 37 kg/s in 100 %THA (Turbine Heat Acceptance), 78.7 kg/s and 37 kg/s in 90 %THA, 81 kg/s and 31.4 kg/s in 75 %THA, 76.3 kg/s and 31 kg/s in 60 %THA, 68.2 kg/s and 31.2 kg/s in 50 %THA load, respectively. And the standard coal consumption rates can be reduced by 39.85 g/kWh, 39.47 g/kWh, 38.08 g/ kWh, 35.50 g/kWh and 35.25 g/kWh, respectively. Both the boiler thermal efficiency and overall thermal efficiency of the TSACPG system descend sightly and the boiler exergy efficiency ascends. With the decline of the load, the solar-to-electricity efficiency, the power output and the proportion of solar power generation descend gradually. And they can reach up to 28.62%, 120.90 MW and 18.32% in 100 %THA load, respectively. The economic performance analysis of the TSACPG system is carried out. The system configuration and investment corresponding to different typical days, different thermal energy storage hours and capacities are considered. The payback times and the levelized costs of electricity of the solar field in different DNI level regions are analyzed. The results show that these two evaluation indices are the lowest in high level DNI region and they are on the contrary in low level DNI region. As for the environmental protection, the CO2 emission rates are reduced by 69.26 g/kWh in 100 %THA, 68.61 g/kWh in 90 %THA, 66.19 g/kWh in 75 %THA, 61.69 g/kWh in 60 %THA and 61.26 g/kWh in 50 %THA load, respectively. The maximum annual CO2 emission can be reduced about 526739.55 tons. The renewable energy and traditional fossil energy are integrated organically in this study and the low-carbon transformation of coal-fired power generation system is further promoted. The study also contributes to the realization of both the carbon peak and the carbon neutralization.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Performance Analysis of an Efficient Integration System of Coal-Fired Power Plant, Solar Thermal Energy and CO2 Capture
    Wang, Yuhao
    Wang, Ruilin
    Liu, Lanhua
    Xing, Chenjian
    Guo, Yafei
    Yang, Qingshan
    Ying, Jiaheng
    Sun, Jian
    Li, Wenjia
    Liu, Yuanyuan
    Zhao, Chuanwen
    JOURNAL OF THERMAL SCIENCE, 2024, 33 (04) : 1509 - 1522
  • [42] Utilization of solar energy in a coal-fired plant
    Cui Yinghong
    Yang Yongping
    Chen Juan
    CHALLENGES OF POWER ENGINEERING AND ENVIRONMENT, VOLS 1 AND 2, 2007, : 1207 - +
  • [43] Off-design thermodynamic performances of a combined solar tower and parabolic trough aided coal-fired power plant
    Liu, Hongtao
    Zhai, Rongrong
    Patchigolla, Kumar
    Turner, Peter
    Yang, Yongping
    APPLIED THERMAL ENGINEERING, 2021, 183
  • [44] DYNAMIC SIMULATION STUDY ON A COAL-FIRED POWER PLANT AIDED WITH LOW-TEMPERATURE SOLAR ENERGY
    Li, Xin
    Zhao, Yongliang
    Liu, Ming
    Yan, Junjie
    PROCEEDINGS OF THE ASME POWER CONFERENCE, 2019, 2019,
  • [45] Characteristics analysis of solar aided coal fired power plant
    Hu, Yongsheng
    Qin, Yan
    Yang, Yongping
    Energy Education Science and Technology Part A: Energy Science and Research, 2013, 31 (01): : 625 - 628
  • [46] Exergoeconomic and exergoenvironmental analysis of a coal-fired thermal power plant
    Duzcan, Abdullah
    Kara, Yusuf Ali
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2021, 43 (12)
  • [47] Fuel Saving in Coal-fired Power Plant with Augmentation of Solar Energy
    Patel, Vivek
    Saha, Balaram
    Chatterjee, Kalyan
    2014 INTERNATIONAL CONFERENCE ON POWER, CONTROL AND EMBEDDED SYSTEMS (ICPCES), 2014,
  • [48] Exergoeconomic and exergoenvironmental analysis of a coal-fired thermal power plant
    Abdullah Duzcan
    Yusuf Ali Kara
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2021, 43
  • [49] Safety and thermal efficiency performance assessment of solar aided coal-fired power plant based on turbine steam double reheat
    Li, Jianlan
    Xin, Yu
    Hu, Bo
    Zeng, Kuo
    Wu, Zhiyi
    Fan, Shiwang
    Li, Yuanyuan
    Chen, Yongzhao
    Wang, Shunjiang
    Wang, Jizhou
    Min, Yong
    Li, Jun
    Flamant, Gilles
    ENERGY, 2021, 226
  • [50] 4-E (Energy, Exergy, Environment, and Economic) analysis of solar thermal aided coal-fired power plants
    Suresh, M. V. J. J.
    Reddy, K. S.
    Kolar, Ajit Kumar
    ENERGY FOR SUSTAINABLE DEVELOPMENT, 2010, 14 (04) : 267 - 279