Experimental behaviour of extended end-plate composite beam-to-column joints subjected to reversal of loading

被引:1
|
作者
Hu, Xiamin [1 ]
Zheng, Desheng [1 ]
Yang, Li [1 ]
机构
[1] Nanjing Univ Technol, Coll Civil Engn, Nanjing 210009, Peoples R China
关键词
composite joints; cyclic loading; moment rotational response;
D O I
10.12989/sem.2006.24.3.307
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper is concerned with the behaviour of steel and concrete composite joints subjected to reversal of loading. Three cruciform composite joint specimens and one bare steel joint specimen were tested so that one side of the beam-to-column connection was under negative moment and another side under positive moment. The steelwork beam-to-column connections were made of bolted end plate with an extended haunch section. Composite slabs employing metal decking were used for all the composite joint specimens. The moment-rotation relationships for the joints were obtained experimentally. Details of the experimental observations and results were reported.
引用
收藏
页码:307 / 321
页数:15
相关论文
共 50 条
  • [31] Calibration of model parameters for the cyclic response of end-plate beam-to-column steel-concrete composite joints
    Nogueiro, Pedro
    da Silva, Luis Simoes
    Bento, Rita
    Simoes, Rui
    STEEL AND COMPOSITE STRUCTURES, 2009, 9 (01): : 39 - 58
  • [32] Experimental study of steel-timber composite beam-to-column joints with extended end plates
    Ataei, Abdolreza
    Valipour, Hamid R.
    Bradford, Mark A.
    Chiniforush, Alireza A.
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 226 : 636 - 650
  • [33] Hysteresis Envelope Model of Double Extended End-Plate Bolted Beam-to-Column Joint
    Krolo, Paulina
    Grandic, Davor
    BUILDINGS, 2021, 11 (11)
  • [34] LOW-CYCLE HYSTERETIC BEHAVIOR OF BEAM-TO-COLUMN EXTENDED END-PLATE CONNECTIONS
    Liu, Shao-Wen
    Hao, Ji-Ping
    Yang, Peng-Fei
    Zheng, Jiang
    PROCEEDINGS OF THE TENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING FOR YOUNG EXPERTS, VOLS I AND II, 2008, : 939 - 943
  • [35] Experimental study on static load-carrying capacity of stainless steel end-plate beam-to-column joints
    Yuan, Huanxin
    Gao, Jundong
    Du, Xinxi
    Yan, Gang
    Jiang, Qinglin
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2021, 42 (12): : 125 - 132
  • [36] Numerical and analytical study of stainless steel beam-to-column extended end-plate connections
    Eladly, Mohammed M.
    Schafer, Benjamin W.
    ENGINEERING STRUCTURES, 2021, 240
  • [37] Numerical and experimental behavior of beam-to-column extended end plate connections
    Maggi, YI
    Gonçalves, RM
    Calado, L
    STESSA 2003: BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, 2003, : 343 - 349
  • [38] Calculation of initial stiffness of beam-to-column end-plate joint
    Shanghai University of Electric Power, Shanghai 200090, China
    不详
    Gongcheng Lixue/Engineering Mechanics, 2008, 25 (08): : 109 - 115
  • [39] Behaviour of composite beam-column flush end-plate connections subjected to low-probability, high-consequence loading
    Mirza, O.
    Uy, B.
    ENGINEERING STRUCTURES, 2011, 33 (02) : 647 - 662
  • [40] BEHAVIOR OF FLEXIBLE END PLATE BEAM-TO-COLUMN JOINTS
    AGGARWAL, AK
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1990, 16 (02) : 111 - 134