Vaulting quantification during level walking of transfemoral amputees

被引:20
|
作者
Drevelle, Xavier [1 ]
Villa, Coralie [2 ]
Bonnet, Xavier [3 ]
Loiret, Isabelle [4 ]
Fode, Pascale [1 ]
Pillet, Helene [2 ]
机构
[1] Inst Natl Invalides, Ctr Etud & Rech Appareillage Handicapes, F-57147 Woippy, France
[2] Arts & Metiers ParisTech, LBM, F-75013 Paris, France
[3] PROTEOR, F-21250 Seurre, France
[4] Ctr Med Phys & Readaptat Louis Pierquin IRR UGECA, F-54042 Nancy, France
关键词
Biomechanics; Gait analysis; Transfemoral amputees; Vaulting; Kinematics; Kinetics; HUMAN JOINT MOTION; ISB RECOMMENDATION; MUSCLE POWER; GAIT; DEFINITIONS; CHILDREN; LIMB;
D O I
10.1016/j.clinbiomech.2014.04.006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Vaulting is a gait compensatory mechanism used by transfemoral amputees to assist toe clearance during the prosthetic swing phase. It is defined by a plantar flexion of the contralateral ankle during the single-limb support phase. The aim of the study is to propose a method to quantify vaulting of transfemoral amputees. Methods: 17 transfemoral amputees and 28 asymptomatic subjects participated in the data collection. Kinematics and kinetics of the whole body were recorded while subjects were walking on a level surface. Biomechanical gait analysis was focused on a reduced set of parameters linked to the contralateral ankle, the contralateral knee and the trajectory of the center of pressure. The patients were classified in two groups: with or without vaulting using video recordings. Differences between both groups and the control group were analyzed. Findings: A higher generated ankle power was found during the single support phase of the contralateral limb of transfemoral amputees presenting vaulting. These subjects presented also a higher dissipated knee flexion power before the peak in ankle flexion power. The trajectory of the center of pressure was also modified by the vaulting. Interpretation: Vaulting for transfemoral amputees is characterized by a propulsive plantar flexion at the contralateral ankle. Quantifying the ankle flexion power during the contralateral single support phase will help in understanding vaulting. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:679 / 683
页数:5
相关论文
共 50 条
  • [31] ENERGY COST OF WALKING OF AMPUTEES - INFLUENCE OF LEVEL OF AMPUTATION
    WATERS, RL
    PERRY, J
    ANTONELLI, D
    HISLOP, H
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (01): : 42 - 46
  • [32] Postural asymmetries in transfemoral amputees
    Gaunaurd, Ignacio
    Gailey, Robert
    Hafner, Brian J.
    Gomez-Marin, Orlando
    Kirk-Sanchez, Neva
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2011, 35 (02) : 171 - 180
  • [33] The Impact of Different Self-Selected Walking Speeds on Muscle Synergies in Transfemoral Amputees during Transient-State Gait
    Mehryar, Pouyan
    Shourijeh, Mohammad
    Rezaeian, Tahmineh
    Khandan, Aminreza
    Messenger, Neil
    O'Connor, Rory
    Farahmand, Farzam
    Dehghani-Sanij, Abbas
    BIOMECHANICS, 2024, 4 (01): : 14 - 33
  • [34] Walking abilities improvements are associated with pelvis and trunk kinematic adaptations in transfemoral amputees after rehabilitation
    Persine, S.
    Leteneur, S.
    Gillet, C.
    Bassement, J.
    Charlate, F.
    Simoneau-Buessinger, E.
    CLINICAL BIOMECHANICS, 2022, 94
  • [35] SELF-SELECTED AND OPTIMAL WALKING SPEED OF TRANSFEMORAL AMPUTEES: GROUND VS. TREADMILL
    Luisa Bona, Renata
    Gomenuka, Natalia Andrea
    Bonezi dos Santos, Artur
    Storniolo, Jorge
    da Silva, Paula Figueiredo
    Peyre Tartaruga, Leonardo Alexandre
    REVISTA BRASILEIRA DE MEDICINA DO ESPORTE, 2016, 22 (05) : 336 - 339
  • [36] Leg stiffness during sprinting in transfemoral amputees with running specific prosthesis
    Sano, Yoko
    Makimoto, Atsushi
    Hashizume, Satoru
    Murai, Akihiko
    Kobayashi, Yoshiyuki
    Takemura, Hiroshi
    Hobara, Hiroaki
    GAIT & POSTURE, 2017, 56 : 65 - 67
  • [37] MYOELECTRIC ACTIVATION DIFFERENCES IN TRANSFEMORAL AMPUTEES DURING LOCOMOTOR STATE TRANSITIONS
    Nakamura, Bryson H.
    Hahn, Michael E.
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2016, 28 (06):
  • [38] Evaluation of hip transfemoral amputees during isometric contraction in isokinetic dynamometer
    Maraes, V. R. F. S.
    Cruz, B. O. A. M.
    Moreira, J. A.
    Almeida, C. C.
    Sampaio, T. F.
    Garcia, P. A.
    Borges, G. A.
    2013 PAN AMERICAN HEALTH CARE EXCHANGES (PAHCE), 2013,
  • [39] Assessment of transfemoral amputees using a passive microprocessor-controlled knee versus an active powered microprocessor-controlled knee for level walking
    Creylman, Veerle
    Knippels, Ingrid
    Janssen, Paul
    Biesbrouck, Evelyne
    Lechler, Knut
    Peeraer, Louis
    BIOMEDICAL ENGINEERING ONLINE, 2016, 15
  • [40] HIP EVALUATION OF TRANSFEMORAL AMPUTEES DURING ISOMETRIC CONTRACTION IN ISOKINETIC DYNAMOMETER
    Fernandes da Silva Maraes, Vera Regina
    de Almeida Marques da Cruz, Bruna Oliveira
    Moreira, Juliana Aparecida
    de Sampaio, Tainara Ferreira
    Almeida, Camila Cadena
    Garcia, Patricia Azevedo
    REVISTA BRASILEIRA DE MEDICINA DO ESPORTE, 2014, 20 (05) : 336 - 339