Importance of Implantable Cardioverter-Defibrillator Back-Up in Cardiac Resynchronization Therapy Recipients: A Systematic Review and Meta-Analysis

被引:30
|
作者
Barra, Sergio [1 ]
Providencia, Rui [2 ]
Tang, Anthony [3 ]
Heck, Patrick [1 ]
Virdee, Munmohan [1 ]
Agarwal, Sharad [1 ]
机构
[1] Papworth Hosp NHS Fdn Trust, Dept Cardiol, Cambridge CB23 3RE, England
[2] Barts Hlth NHS Trust, Barts Heart Ctr, London, England
[3] Univ Western Ontario, London, ON, Canada
来源
关键词
cardiac resynchronization therapy; heart failure; implantable cardioverter-defibrillator; mortality; sudden death; LONG-TERM SURVIVAL; LEFT-VENTRICULAR DYSFUNCTION; CONGESTIVE-HEART-FAILURE; PRIMARY PREVENTION; FOLLOW-UP; CLINICAL-OUTCOMES; IMPROVE SURVIVAL; SUPER-RESPONSE; HIGH-VOLUME; CRT-D;
D O I
10.1161/JAHA.115.002539
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-It remains to be determined whether patients receiving cardiac resynchronization therapy (CRT) benefit from the addition of an implantable cardioverter-defibrillator (ICD). Methods and Results-We performed a literature search looking for studies of patients implanted with CRTs. Comparisons were performed between patients receiving CRT-defibrillator (CRT-D) versus CRT-pacemaker (CRT-P). The primary outcome was all-cause mortality. Data were pooled using a random-effects model. The relative risk (RR) and hazard ratio (HR, when available) were used as measurements of treatment effect. Nineteen entries were entitled for inclusion, comprising 12 378 patients (7030 receiving CRT-D and 5348 receiving CRT-P) and 29 799 patient-years of follow-up. Those receiving CRT-D were younger, were more often males, had lower NYHA class, lower prevalence of atrial fibrillation, higher prevalence of ischemic heart disease, and were more often on beta-blockers. Ten studies showed significantly lower mortality rates with the CRT-D device, while the remaining 9 were neutral. The pooled data of studies revealed that CRT-D patients had significantly lower mortality rates compared with CRT-P patients (mortality rates: CRT-D 16.6% versus CRT-P 27.1%; RR=0.69, 95% CI 0.62-0.76; P<0.00001). The number needed to treat to prevent one death was 10. The observed I-2 values showed moderate heterogeneity among studies (I-2=48%). The benefit of CRT-D was more pronounced in ischemic cardiomyopathy (HR=0.70, 95% CI 0.59-0.83, P<0.001, I-2=0%), but a trend for benefit, albeit of lower magnitude, could also be seen in non-ischemic dilated cardiomyopathy (HR=0.79, 95% CI 0.61-1.02, P=0.07, I-2=36%). Conclusions-The addition of the ICD associates with a reduction in the risk of all-cause mortality in CRT patients. This seems to be more pronounced in patients with ischemic cardiomyopathy.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] The benefits of adding a defibrillator to cardiac resynchronization therapy - systematic review and meta-analysis
    Veres, B.
    Gharehdaghi, S.
    Engh, M.
    Schwertner, W.
    Kuthi, L.
    Merkel, E. D.
    Masszi, R.
    Fehervari, P.
    Behon, A.
    Osztheimer, I.
    Hegyi, P.
    Kovacs, A.
    Zima, E.
    Kosztin, A.
    Merkely, B.
    EUROPEAN HEART JOURNAL, 2022, 43 : 735 - 735
  • [32] Multiple shocks after upgrade of an implantable cardioverter-defibrillator to a cardiac resynchronization therapy-defibrillator device
    Francisco, Gregory M.
    Sharma, Saumya
    Dougherty, Anne H.
    Kantharia, Bharat K.
    CARDIOLOGY JOURNAL, 2009, 16 (05) : 473 - 476
  • [33] The benefits of adding a defibrillator to cardiac resynchronization therapy - systematic review and meta-analysis
    Veres, B. Boglarka
    Schwertner, W. R.
    Engh, M.
    Ghare, S.
    Kuthi, L.
    Merkel, E. D.
    Behon, A.
    Masszi, R.
    Osztheimer, I.
    Zima, E.
    Geller, L.
    Hegyi, P.
    Fehervari, P.
    Kosztin, A.
    Merkely, B.
    EUROPEAN JOURNAL OF HEART FAILURE, 2022, 24 : 10 - 11
  • [34] An implantable cardioverter-defibrillator for primary prevention in non-ischemic cardiomyopathy: A systematic review and meta-analysis
    Wasiak, Michal
    Tajstra, Mateusz
    Kosior, Dariusz
    Gasior, Mariusz
    CARDIOLOGY JOURNAL, 2021,
  • [35] Implantable Cardioverter-Defibrillator for Nonischemic Cardiomyopathy An Updated Meta-Analysis
    Golwala, Harsh
    Bajaj, Navkaranbir Singh
    Arora, Garima
    Arora, Pankaj
    CIRCULATION, 2017, 135 (02) : 201 - 203
  • [36] An implantable cardioverter-defibrillator for primary prevention in non-ischemic cardiomyopathy: A systematic review and meta-analysis
    Wasiak, Michal
    Tajstra, Mateusz
    Kosior, Dariusz
    Gasior, Mariusz
    CARDIOLOGY JOURNAL, 2023, 30 (01) : 117 - 124
  • [37] Implantable Cardioverter-Defibrillator Use in Patients With Left Ventricular Assist Devices A Systematic Review and Meta-Analysis
    Vakil, Kairav
    Kazmirczak, Felipe
    Sathnur, Neeraj
    Adabag, Selcuk
    Cantillon, Daniel J.
    Kiehl, Erich L.
    Koene, Ryan
    Cogswell, Rebecca
    Anand, Inderjit
    Roukoz, Henri
    JACC-HEART FAILURE, 2016, 4 (10) : 772 - 779
  • [38] Implantable cardioverter defibrillator in nonischemic cardiomyopathy: A systematic review and meta-analysis
    Khan, Safi U.
    Ghimire, Subash
    Talluri, Swapna
    Rahman, Hammad
    Khan, Muhammad U.
    Nasir, Fahad
    Kaluski, Edo
    JOURNAL OF ARRHYTHMIA, 2018, 34 (01) : 4 - 10
  • [39] Statins Reduce Appropriate Cardioverter-Defibrillator Shocks and Mortality in Patients With Failure and Combined Heart Cardiac Resynchronization and Implantable Cardioverter-Defibrillator Therapy
    Desai, Harit
    Aronow, Wilbert S.
    Tsai, Fausan S.
    Ahn, Chu
    Lai, Hoang M.
    Amin, Harshad
    Gandhi, Kaushang
    Frishman, William H.
    Cohen, Martin
    Sorbera, Carmine
    JOURNAL OF CARDIOVASCULAR PHARMACOLOGY AND THERAPEUTICS, 2009, 14 (03) : 176 - 179
  • [40] Combined resynchronization and implantable cardioverter defibrillator therapy: meta-analysis of randomized controlled trials
    Bonanno, C.
    Morato, M.
    Paccanaro, M.
    Ometto, R.
    Fontanelli, A.
    EUROPEAN HEART JOURNAL, 2010, 31 : 413 - 413