Translucency parameter of conventional restorative glass-ionomer cements

被引:8
|
作者
Uchimura, Joana Yumi Teruya [1 ]
Sato, Francielle [2 ]
Santana, Rosangela Getirana [3 ]
Menezes-Silva, Rafael [4 ]
Bueno, Ligia S. [4 ]
Borges, Ana Flavia Sanches [4 ]
de Lima Navarro, Maria Fidela [4 ]
Nicholson, John W. [5 ]
Sidhu, Sharanbir K. [5 ]
Pascotto, Renata Correa [1 ]
机构
[1] Univ Estadual Maringa, Dept Dent, Av Mandacaru 1-550, BR-87080000 Maringa, Parana, Brazil
[2] Univ Estadual Maringa, Dept Phys, Maringa, Parana, Brazil
[3] Univ Estadual Maringa, Dept Stat, Maringa, Parana, Brazil
[4] Univ Sao Paulo, Bauru Sch Dent FOB USP Bauru, Bauru Sch Dent, Dept Operat Dent Endodont & Dent Mat, Sao Paulo, Brazil
[5] Queen Mary Univ London, Barts & London Sch Med & Dent, Inst Dent, London, England
基金
巴西圣保罗研究基金会;
关键词
color; dental materials; glass‐ ionomer cements; opacity; translucency; OPTICAL-PROPERTIES; RESIN COMPOSITES; MASKING ABILITY; COLOR;
D O I
10.1111/jerd.12685
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective To evaluate the translucency parameter (TP) and contrast ratio (CR) of different conventional restorative glass-ionomer cements (GICs). Materials and methods Eighteen brands of GICs were evaluated. Five disks of each material were made following ISO 9917-1. The luminous reflectance and Central Bureau of the International Commission on Illumination parameters of disks were evaluated using a colorimeter, against backings of white and black, to obtain the translucent parameter and contrast ratio of different brands of glass-ionomer cements. The correlation between translucency parameter and contrast ratio was assessed with the Pearson correlation test. The translucent and contrast ratio parameters values were submitted to the one-way ANOVA and Tukey test for multiple comparisons (p < 0.05). Results There was a strong inverse relationship between CR and TP (r(2) = 0.94, p < 0.001). The contrast ratio decreased as translucency increased. There were significant differences in TP and CR among brands (p < 0.001). Conlusions GICs exhibit different translucency and contrast ratio behavior. Some brands of GICs presented very low TP and this condition would be unacceptable for areas with esthetic demands. In addition, TP and CR showed a strong linear relationship. Clinical significance The results found in this study demonstrated that the knowledge of the translucency and CR of different conventional restorative GICs is important in order to guide clinicians in the selection of restorative GICs for anterior teeth.
引用
收藏
页码:935 / 942
页数:8
相关论文
共 50 条
  • [41] Biocompatibility of glass-ionomer bone cements
    Hatton, P. V.
    Hurrell-Gillingham, K.
    Brook, I. M.
    JOURNAL OF DENTISTRY, 2006, 34 (08) : 598 - 601
  • [42] FINISHING AND POLISHING GLASS-IONOMER CEMENTS
    EIDE, R
    TVEIT, AB
    ACTA ODONTOLOGICA SCANDINAVICA, 1990, 48 (06) : 409 - 413
  • [43] STRENGTH CHARACTERISTICS OF GLASS-IONOMER CEMENTS
    KERBY, RE
    KNOBLOCH, L
    OPERATIVE DENTISTRY, 1992, 17 (05) : 170 - 174
  • [44] EARLY STRENGTH OF GLASS-IONOMER CEMENTS
    CATTANILORENTE, MA
    GODIN, C
    MEYER, JM
    DENTAL MATERIALS, 1993, 9 (01) : 57 - 62
  • [45] MARGINAL ADAPTATION OF GLASS-IONOMER CEMENTS
    FUKS, AB
    HIRSCHFELD, Z
    GRAJOWER, R
    JOURNAL OF PROSTHETIC DENTISTRY, 1983, 49 (03): : 356 - 360
  • [46] LEACHING FROM GLASS-IONOMER CEMENTS
    BAPNA, MS
    MUELLER, HJ
    JOURNAL OF ORAL REHABILITATION, 1994, 21 (05) : 577 - 583
  • [47] Secondary reactions in glass-ionomer cements
    Wilson, AD
    JOURNAL OF MATERIALS SCIENCE LETTERS, 1996, 15 (03) : 275 - 276
  • [49] Antibacterial activity of glass-ionomer restorative cements exposed to cavity-producing microorganisms
    Herrera, M
    Castillo, A
    Baca, P
    Carrión, P
    OPERATIVE DENTISTRY, 1999, 24 (05) : 286 - 291
  • [50] CLINICAL-EVALUATION OF 2 LIGHT-CURED RESTORATIVE GLASS-IONOMER CEMENTS
    MANFIO, AP
    BELTRAO, HCP
    NAVARRO, MFL
    SOUZA, MHS
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 434 - 434