共 50 条
Diffusion-weighted Imaging in Ischemic Stroke: Effect of Display Method on Observers' Diagnostic Performance
被引:27
|作者:
Hirai, Toshinori
[1
]
Sasaki, Makoto
[6
]
Maeda, Masayuki
[7
]
Ida, Masahiro
[8
]
Katsuragawa, Shigehiko
[9
]
Sakoh, Masaharu
[10
]
Takano, Koichi
[11
]
Arai, Shoichi
[11
]
Hirano, Teruyuki
[2
]
Kai, Yutaka
[3
]
Kakeda, Shingo
[12
]
Murakami, Ryuji
[4
]
Ikeda, Ryuji
[5
]
Fukuoka, Hirofumi
[1
]
Sasao, Akira
[1
]
Yamashita, Yasuyuki
[1
]
机构:
[1] Kumamoto Univ, Dept Diagnost Radiol, Kumamoto 8608556, Japan
[2] Kumamoto Univ, Dept Neurol, Kumamoto 8608556, Japan
[3] Kumamoto Univ, Dept Neurosurg, Kumamoto 8608556, Japan
[4] Kumamoto Univ, Dept Radiat Oncol, Grad Sch Med Sci, Kumamoto 8608556, Japan
[5] Kumamoto Univ, Kumamoto Univ Hosp, Kumamoto 8608556, Japan
[6] Iwate Med Univ, Adv Med Res Ctr, Morioka, Iwate 020, Japan
[7] Mie Univ, Sch Med, Dept Radiol, Tsu, Mie, Japan
[8] Ebara Hosp, Dept Radiol, Tokyo, Japan
[9] Kumamoto Univ, Sch Hlth Sci, Dept Radiol Technol, Kumamoto, Japan
[10] Hatsudai Rehabil Hosp, Dept Rehabil, Tokyo, Japan
[11] Fukuoka Univ, Sch Med, Dept Radiol, Fukuoka 81401, Japan
[12] Univ Occupat & Environm Hlth, Sch Med, Dept Radiol, Kitakyushu, Fukuoka 807, Japan
关键词:
Diffusion-weighted imaging;
ischemic stroke;
display method;
COMPUTER-AIDED DIAGNOSIS;
HYPERACUTE STROKE;
INFARCTION;
MISMATCH;
MRI;
CT;
DESMOTEPLASE;
THROMBOLYSIS;
ACCURACY;
BRAIN;
D O I:
10.1016/j.acra.2008.09.012
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Rationale and Objectives. When evaluating ischemic stroke oil diffusion-weighted magnetic resonance imaging (DWI), the display method has not been investigated. The purpose of this study was to determine whether standardization of the display method for DWI affects observers' diagnostic performance in detecting ischemic stroke on DWI. Materials and Methods. Twenty-six observers evaluated 40 DWI studies in 20 patients with acute (< 6 hours) middle cerebral arterial strokes and 20 controls for the presence of hyperintense lesions in 10 areas using the Alberta Stroke Programme Early CT Score (ASPECTS) system and one area in the corona radiata using a modified version of the ASPECTS system (ASPECTS-DWI). The images were reviewed using a standardized display method (SDM) and a conventional display method (CDM). The reading time was recorded for each session. The observers' performance was evaluated with receiver-operating characteristic analysis. Results. In all observers with ASPECTS-DWI scores of <= 8 points, the value of the mean average area under the receiver-operating characteristic Curve was slightly higher for the SDM than the CDM, but the difference was not statistically significant. In the insular ribbon, diagnostic accuracy was significantly higher with the SDM than the CDM (P =.036). In the other locations, there were no significant differences. With the SDM, the mean reading time was reduced by 7.5 seconds (P =.024). Conclusion. The SDM improved diagnostic accuracy for the insular ribbon and shortened the reading time, although it did not improve observers' performance with the ASPECTS-DWI system.
引用
收藏
页码:305 / 312
页数:8
相关论文