Diagnostic value of diffusion-weighted STEAM-MRI in ischemic stroke

被引:3
|
作者
Mueller, Sebastian Johannes [1 ]
Khadhraoui, Eya [1 ]
Van Kube, Julia My [1 ]
Langer, Philip [1 ]
Riedel, Christian Heiner [1 ]
Voit, Dirk [2 ]
Ernst, Marielle [1 ]
Frahm, Jens [2 ]
机构
[1] Univ Med Ctr Gottingen, Dept Neuroradiol, Robert Koch Str 40, D-37075 Gottingen, Germany
[2] Max Planck Inst Biophys Chem, Gottingen, Germany
关键词
STEAM; Stroke; DWI; Susceptibility; Artifacts; SUSCEPTIBILITY ARTIFACTS; WHOLE-BRAIN;
D O I
10.1016/j.ejrad.2021.109677
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Diffusion-weighted imaging in stimulated echo acquisition mode (STEAM-DWI) is an interesting alternative with less susceptibility artifacts compared to the most commonly used diffusion-weighted echo-planar imaging (EPI-DWI). Sensitivity and specificity of a novel STEAM-DWI, described by Merrem et al. 2017 [1], were assessed in patients with ischemic stroke. Methods: EPI- and STEAM-DWIs were performed in patients with suspected subacute stroke between 01 July 2019 and 30 June 2020 using 3-T MRI. Three neuroradiologists independently and separately rated STEAM-DWI images with respect to (i) signs of an acute/subacute stroke, (ii) the number, size and localization of infarctions and, (iii) the presence of artifacts. Results: In 55 (23 right, 23 left, 9 both hemispheres) of 85 patients a subacute stroke was confirmed using EPIDWI. The cerebral vascular territories were affected as follows: anterior cerebral artery 8 %, middle cerebral artery 48 %, posterior cerebral artery 27 %, brainstem 7 %, cerebellum 10 %. In 53 of 55 (96 %) cases the stroke was detected by usage of STEAM-DWI, in 35 of 37 patients microembolic events were noticed (95 %). Results showed a sensitivity and specificity of 100 % (70/70) for major infarcts (>9 mm(2) in-plane) and a sensitivity of up to 94 % (121/129) for detecting subacute microembolic lesions. No susceptibility artifacts were noticed in STEAM-DWI. Conclusion: Compared to standard EPI-DWI, STEAM-DWI offers a more robust alternative for diagnosing subacute strokes in areas affected by susceptibility artifacts.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Sensitivity of Diffusion-Weighted STEAM MRI and EPI-DWI to Infratentorial Ischemic Stroke
    Khalil, Ahmed A.
    Hohenhaus, Marc
    Kunze, Claudia
    Schmidt, Wolf
    Brunecker, Peter
    Villringer, Kersten
    Merboldt, Klaus-Dietmar
    Frahm, Jens
    Fiebach, Jochen B.
    PLOS ONE, 2016, 11 (08):
  • [2] Diffusion-weighted MRI for diagnosis and treatment of ischemic stroke
    Zivin, JA
    ANNALS OF NEUROLOGY, 1997, 41 (05) : 567 - 568
  • [3] Sensitivity and specificity of perfusion- and diffusion-weighted MRI in ischemic stroke
    Barber, P
    Parsons, M
    Darby, D
    Desmond, P
    Gerraty, D
    Yang, Q
    Tress, B
    Davis, S
    STROKE, 2000, 31 (11) : 2807 - 2807
  • [4] Leukoaraiosis, ischemic stroke, and normal white matter on diffusion-weighted MRI
    Helenius, J
    Soinne, L
    Salonen, O
    Kaste, M
    Tatlisumak, T
    STROKE, 2002, 33 (01) : 45 - 50
  • [5] Ischemic Lesions In Patients With Migrainous Stroke: A Diffusion-weighted MRI Study
    Wolf, Marc E.
    Szabo, Kristina
    Grielbe, Martin
    Foerster, Alex
    Gass, Achim
    Hennerici, Michael G.
    Kern, Rolf
    STROKE, 2009, 40 (04) : E195 - E195
  • [6] DIFFUSION-WEIGHTED MRI OF CLINICAL STROKE
    MOSELEY, ME
    YENARI, M
    DECRESPIGNY, A
    MARKS, M
    NEUROLOGY, 1995, 45 (04) : A286 - A287
  • [7] Diffusion-weighted MRI of ischemic stroke at 3T: Value of synthetic b-values
    Sartoretti, Thomas
    Sartoretti, Elisabeth
    Wyss, Michael
    Mannil, Manoj
    van Smoorenburg, Luuk
    Eichenberger, Barbara
    Reischauer, Carolin
    Alfieri, Alex
    Binkert, Christoph
    Sartoretti-Schefer, Sabine
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1121):
  • [8] Predictive value of diffusion-weighted imaging in acute ischemic stroke.
    Baird, AE
    Chaves, C
    Silver, B
    Caplan, L
    Edelman, R
    Warach, S
    ANNALS OF NEUROLOGY, 1999, 46 (03) : 478 - 479
  • [9] The Value of Diffusion-Weighted MRI in CT-Negative Stroke Mimickers
    Goksu, Erkan
    Unal, Ali
    Enver, Selcan
    Karaali, Kamil
    Korkmaz, Neslihan
    Kartal, Mutlu
    TURKIYE KLINIKLERI TIP BILIMLERI DERGISI, 2011, 31 (03): : 597 - 601
  • [10] The Diagnostic Value of Conventional MRI Combined With Diffusion-Weighted Imaging in Microprolactinomas
    Wang, Min-Yang
    Yu, Ying
    Han, Yu
    Yang, Yang
    Jiang, Wan
    Liu, Jin
    Yan, Lin-Feng
    Cui, Guang-Bin
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2025, 61 (03) : 1155 - 1167