Mojette tomographic reconstruction for micro-CT: a bone and vessels quality evaluation

被引:0
|
作者
Sarkissian, H. Der [1 ,2 ]
Recur, B. [3 ]
Guedon, Jp. [1 ]
Blerya, P. [1 ,4 ]
Pilet, P. [4 ]
Amouriq, Y. [1 ,4 ]
机构
[1] Univ Nantes, LUNAM Univ, IRCCyN UMR CNRS 6597, Polytech Nantes, Rue Christian Pauc BP 50609, F-44306 Nantes, France
[2] Res Dept, BKEOSYS, F-44800 Saint Herblain, France
[3] Australian Natl Univ, Dept Appl Maths, RSPE, Canberra, ACT, Australia
[4] DLUNAM Univ, Univ Nantes, LIOAD INSERM UMR S 791, Odontol Nantes, Nantes, France
关键词
Discrete tomography; Mojette transform; micro-CT; bone-vessels imaging;
D O I
10.1117/12.2043062
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Micro-CT represents a modality where the quality of CT reconstruction is very high thanks to the acquisition properties. The goal of this paper is to challenge our proposed Mojette discrete reconstruction scheme from real micro-CT data. A first study was done to analyze bone image degradations by lowering the number of projections. A second study analyzes trabecular bone and vessels tree through an animal study. Small vessels are filling trabecular holes with almost the same grey levels as the bone. Therefore vessel detectability that can be achieved from the reconstruction algorithm according to the number of projections is a major issue.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Obturation quality of bioceramic sealers with different obturation techniques: a micro-CT evaluation
    Alkahtany, Sarah M.
    Alhussain, Asma A.
    Almthen, Haifa A.
    Aldokhi, Haya D.
    Bukhary, Sundus M.
    Almohaimede, Amal A.
    Alneshmi, Basma
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [22] Performance Evaluation of a Prototype Micro-CT System
    Cho, Seungryong
    Bian, Junguo
    Pelizzari, Charles A.
    Souris, Jeffrey S.
    Chen, Chin-Tu
    Pan, Xiaochuan
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3127 - 3129
  • [23] Development of phantom for performance evaluation of micro-CT
    Tsai, Kevin Wen-Kai
    Chueh, Ho-Shiang
    Chen, Jyh-Cheng
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2008, 20 (03): : 177 - 184
  • [24] Automatic thresholding of micro-CT trabecular bone images
    Zhang, Yongping
    He, Zhongkun
    Fan, Shaojing
    He, Kejia
    Li, Chen
    BMEI 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOL 2, 2008, : 23 - +
  • [25] Challenges for bone mineral density calibration on micro-CT
    Stoico, R.
    Tassani, S.
    Mecozzi, L.
    Falcioni, S.
    Fersini, C.
    Baruffaldi, F.
    COMPUTATIONAL VISION AND MEDICAL IMAGE PROCESSING IV, 2014, : 419 - 423
  • [26] Micro-CT assessment of bone microstructure in baboon mandibles
    Felder, Alessandro A.
    Bocaege, Emmy
    Joganic, Jessica
    JOURNAL OF ANATOMY, 2021, 238 (01) : 209 - 209
  • [27] Influence of segmentation on micro-CT images of trabecular bone
    Tassani, S.
    Korfiatis, V.
    Matsopoulos, G. K.
    JOURNAL OF MICROSCOPY, 2014, 256 (02) : 75 - 81
  • [28] Micro-CT for saw mark analysis on human bone
    Norman, D. G.
    Baier, W.
    Watson, G.
    Burnett, B.
    Painter, M.
    Williams, M. A.
    FORENSIC SCIENCE INTERNATIONAL, 2018, 293 : 91 - 100
  • [29] Application of Micro-CT to the observation of internal structure of bone
    Tamatsu, Y
    Ide, Y
    ANTHROPOLOGICAL SCIENCE, 1999, 107 (01) : 42 - 42
  • [30] A comparison of micro-CT, microradiography and histomorphometry in bone research
    Gielkens, Pepijn F. M.
    Schortinghuis, Jurjen
    de Jong, Johan R.
    Huysmans, Marie Charlotte D. N. J. M.
    van Leeuwen, M. Barbara M.
    Raghoebar, Gerry M.
    Bos, Ruud R. M.
    Stegenga, Boudewijn
    ARCHIVES OF ORAL BIOLOGY, 2008, 53 (06) : 558 - 566