An Alternative Tensiometer Design for Deep Vadose Zone Monitoring

被引:3
|
作者
Kandelous, Maziar M. [1 ]
Moradi, Barzin A. [1 ]
Hopmans, Jan W. [1 ]
机构
[1] Univ Calif Davis, Dept Land Air & Water Resources, Davis, CA 95616 USA
关键词
D O I
10.2136/sssaj2015.03.0121
中图分类号
S15 [土壤学];
学科分类号
0903 ; 090301 ;
摘要
The conventional tensiometer is among the most accurate devices for soil water matric potential measurements, as well as for estimations of soil water flux from soil water potential gradients. Uncertainties associated with conventional tensiometers such as caused by ambient temperature effects and the draining of the tensiometer tube, as well as their limitation for deep soil monitoring, has prevented their widespread use for vadose zone monitoring, despite their superior accuracy in general. We introduce an alternative tensiometer design that offers the accuracy of the conventional tensiometer, while minimizing the aforementioned uncertainties and limitations. The proposed alternative tensiometer largely eliminates temperature-induced diurnal fluctuations and uncertainties associated with draining of the tensiometer tube and removes the limitation in installation depth. In addition, the manufacturing costs of this alternative tensiometer design are close to those of the conventional tensiometer, while it is especially suited for monitoring of soil water potential gradients as required for soil water flux measurements.
引用
收藏
页码:1293 / 1296
页数:4
相关论文
共 50 条
  • [31] Monitoring of Water and Solute Transport in the Vadose Zone: A Review
    Singh, Gurbir
    Kaur, Gurpreet
    Williard, Karl
    Schoonover, Jon
    Kang, Jasjit
    VADOSE ZONE JOURNAL, 2018, 17 (01)
  • [32] VADOSE ZONE MONITORING WITH THE NEUTRON MOISTURE PROBE - REPLY
    KRAMER, JH
    GROUND WATER MONITORING AND REMEDIATION, 1993, 13 (01): : 161 - 162
  • [33] Spatial variability and transport of nitrate in a deep alluvial vadose zone
    Onsoy, YS
    Harter, T
    Ginn, TR
    Horwath, WR
    VADOSE ZONE JOURNAL, 2005, 4 (01): : 41 - 54
  • [34] Continuous temperature logging in air across the deep vadose zone
    Reiter, M
    VADOSE ZONE JOURNAL, 2004, 3 (03) : 982 - 989
  • [35] VADOSE ZONE MONITORING CONCEPTS FOR HAZARDOUS-WASTE SITES
    EVERETT, LG
    WILSON, LG
    MCMILLION, LG
    GROUND WATER, 1982, 20 (03) : 312 - 324
  • [36] Natural attenuation assessment of multiple VOCs in a deep vadose zone
    Peterson, DM
    Singletary, MA
    Studer, JE
    Miller, DR
    NATURAL ATTENUATION CONSIDERATIONS AND CASE STUDIES: REMEDIATION OF CHLORINATED AND RECALCITRANT COMPOUNDS, 2000, : 193 - 200
  • [37] Continuous Monitoring of the Vadose Zone Gas Phase by Mass Spectrometry
    Guillon, S.
    Greau, C.
    Pili, E.
    VADOSE ZONE JOURNAL, 2016, 15 (08)
  • [38] Monitoring of Thick Vadose Zone Water Dynamics Under Irrigation Using a 48 m Deep Caisson at the Luancheng Critical Zone Observatory
    Wu, Lin
    Min, Leilei
    Liu, Meiying
    Zhang, Yucui
    Pei, Hongwei
    Li, Hongjun
    Zhang, Guanglu
    Wang, Shiqin
    Shen, Yanjun
    WATER RESOURCES RESEARCH, 2023, 59 (05)
  • [39] VADOSE ZONE MONITORING - EXPERIENCES AND TRENDS IN THE UNITED-STATES
    CULLEN, SJ
    GROUND WATER MONITORING AND REMEDIATION, 1995, 15 (03): : 136 - 143
  • [40] Perchlorate accumulation and migration in the deep vadose zone in a semiarid region
    Gal, Harel
    Weisbrod, Noam
    Dahan, Ofer
    Ronen, Zeev
    Nativ, Ronit
    JOURNAL OF HYDROLOGY, 2009, 378 (1-2) : 142 - 149