Prototype of a Negative-Sequence Turn-to-Turn Fault Detection Scheme for Transformers

被引:41
|
作者
Zacharias, Daniel [1 ]
Gokaraju, Ramakrishna [1 ]
机构
[1] Univ Saskatchewan, Saskatoon, SK S7N 4K2, Canada
关键词
Digital protection; transformer protection; DESIGN; RELAY;
D O I
10.1109/TPWRD.2015.2483524
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Digital relays are capable of computing the negative-sequence current on both primary and secondary sides of the transformer along with the phase difference between these two negative-sequence currents. By using both phase and magnitude information, negative-sequence current could be used to detect minor turn-to-turn faults involving 3% of the transformer's windings or more. Turn-to-turn faults may still occur even if no current is flowing on one side of the transformer, such as during energization. With no current flowing in the secondary windings of the transformer, negative-sequence current-based algorithms become insensitive. This paper introduces a relay prototype, using both negative-sequence current and negative-sequence voltage, which retains its sensitivity during energization. The relay's performance for several commonly encountered system scenarios, such as overexcitation, current-transformer saturation, nonzero fault resistance, transformer energization, and external faults were also examined. The experimental results presented in this paper indicate that the algorithm proposed in this paper is faster and more sensitive than restrained current differential protection and is capable of detecting turn-to-turn faults occurring during transformer energization.
引用
收藏
页码:122 / 129
页数:8
相关论文
共 50 条
  • [41] Employing neutral-voltage spectrum for internal turn-to-turn fault detection in the induction machine drives
    Jafarian, Mohammad Javad
    Nazarzadeh, Jalal
    ISA TRANSACTIONS, 2018, 81 : 306 - 317
  • [42] Turn-to-Turn Fault Diagnosis on Three-Phase Power Transformer Using Hybrid Detection Algorithm
    Liu, Chien-Hsun
    Muda, Willybrordus H. P.
    Kuo, Cheng-Chien
    APPLIED SCIENCES-BASEL, 2021, 11 (06):
  • [43] Extended second central moment approach to detect turn-to-turn faults in power transformers
    Esponda, Hector
    Vazquez, Ernesto
    Andrade, Manuel A.
    Guillen, Daniel
    Johnson, Brian K.
    IET ELECTRIC POWER APPLICATIONS, 2019, 13 (06) : 773 - 782
  • [44] Diagnosis of stator-winding-turn faults of induction motor by direct detection of negative-sequence currents
    Kato T.
    Inoue K.
    Yoshida K.
    IEEJ Transactions on Industry Applications, 2011, 131 (11) : 1346 - 1353+12
  • [45] Turn-To-Turn Fault Recognition in the Series Winding of an Autotransformer by Differential Protection Methods
    Atnishkin A.B.
    Lyamets Y.Y.
    Power Technology and Engineering, 2018, 52 (4) : 496 - 500
  • [46] Modeling and harmonic analysis of a permanent magnet synchronous machine with turn-to-turn fault
    Harsjo, Joachim
    Bongiorno, Massimo
    2015 17TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'15 ECCE-EUROPE), 2015,
  • [47] The Application of ANN in Fault Diagnosis for Generator Rotor Winding Turn-to-turn Faults
    Ma, Hongzhong
    Ding, Yuanyuan
    Ju, P.
    Zhang, Limin
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 2024 - +
  • [48] Mitigation of Turn-to-Turn Faults in Fault Tolerant Permanent Magnet Synchronous Motors
    Cintron-Rivera, Jorge G.
    Foste, Shanelle N.
    Strangas, Elias G.
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2015, 30 (02) : 465 - 475
  • [49] Protection Scheme Based on the Identification of Equivalent Leakage Inductance Against Turn-to-Turn Fault of Magnetically Controlled Shunt Reactor
    Liu X.
    Zheng T.
    Huang T.
    Zheng, Tao (zhengtao_sf@126.com), 1600, China Machine Press (35): : 134 - 145
  • [50] INDICATION OF TURN-TO-TURN FAULT IN ARMATURE WINDING WITH BALANCING CONNECTIONS FOR DC MACHINES
    BESSUDNOV, YP
    ELECTRICAL TECHNOLOGY RUSSIA, 1971, 2 (04): : 158 - +