摘要
Background: Animal experimental testing is imperative for preclinical evaluation of prosthetic heart valves and implantation techniques. Because human and pig cardiovascular structures including mitral valves show remarkable anatomical similarity, these animals are good candidates for preclinical testing. Previous attempts to establish such long-term models were hampered by both intra- and postoperative difficulties. Our aim was to overcome these difficulties to develop a porcine model for mitral valve replacement (MVR) and furthermore to investigate the practical feasibility of 3 chordal reconstruction procedures. Methods: Sixteen 60-kg pigs were allocated to undergo 1 of 3 surgical procedures, (1) preservation of the entire subvalvular apparatus (n=8), (2) preservation of the secondary chordae only (n=4), or (3) excision of the native valve and papillary resuspension with sutures (n=4). St. Jude Medical valves (29 mm) were implanted during extracorporeal circulation and cold cardioplegic arrest. Postoperative anticoagulation was administered by subcutaneous heparin injections. Results: Fourteen animals survived 1 month, thriving and without signs of heart failure. One animal was euthanized due to irreversible bleeding in the tracheal tube, and another animal died on the third postoperative day owing to valve thrombosis. Conclusion: A practically feasible long-term porcine model of MVR has been established. Because the pig is superior to other species with respect to anatomical and physiological similarity to humans, we consider this model as an optimal platform for experimental preclinical testing of heart valve prostheses.
引用
收藏
页码:E259 / E264
页数:6
相关论文
共 50 条
  • [41] Long-term follow-up of patients with mechanical prosthetic valves in the tricuspid position
    Tomari S.
    Usui A.
    Usui M.
    Fujimoto K.
    Hagiwara H.
    Takagi Y.
    Akita T.
    Ueda Y.
    Journal of Artificial Organs, 2002, 5 (3) : 179 - 183
  • [42] Minimally invasive system for the evaluation of prosthetic heart valves
    Chan, SC
    Oka, M
    Downey, A
    Udpa, SS
    ELECTROMAGNETIC NONDESTRUCTIVE EVALUATION (VIII), 2004, 24 : 247 - 254
  • [43] COMPARATIVE LONG-TERM CLINICAL ANALYSIS OF TISSUE AND PROSTHETIC VALVES IN ONE SURGICAL UNIT
    OBRIEN, MF
    STAFFORD, EG
    GARDNER, MA
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1975, 5 (01): : 79 - 79
  • [44] Long-Term Results After Operations for Active Infective Endocarditis in Native and Prosthetic Valves
    Meszaros, Katharina
    Nujic, Sladjan
    Sodeck, Gottfried H.
    Englberger, Lars
    Koenig, Tobias
    Schoenhoff, Florian
    Reineke, David
    Roost-Kraehenbuehl, Eva
    Schmidli, Juerg
    Czerny, Martin
    Carrel, Thierry P.
    ANNALS OF THORACIC SURGERY, 2012, 94 (04): : 1204 - 1210
  • [45] Role of MDCT in the Evaluation of Prosthetic Heart Valves Reply
    Konen, Eli
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (02) : W78 - W78
  • [46] NATURAL HISTORY OF PATIENTS HAVING PROSTHETIC HEART VALVES MAINTAINED ON LONG TERM ANTICOAGULATION THERAPY
    SIMMONS, E
    HILL, JD
    KERTH, WJ
    GERBODE, F
    CIRCULATION, 1971, 44 (04) : 226 - &
  • [47] LONG-TERM EVALUATION OF MODIFIED PORCINE AORTAS AS A BIOMATERIAL
    PLANCHE, C
    MARRE, P
    IZRAEL, MT
    BATISSE, A
    WEISS, M
    EUROPEAN SURGICAL RESEARCH, 1976, 8 : 197 - 197
  • [48] LONG-TERM EVALUATION OF BIOPROSTHETIC VALVES - 615 CONSECUTIVE CASES
    BLOCH, G
    VOUHE, PR
    MENU, P
    POULAIN, H
    CACHERA, JP
    AUBRY, P
    HEURTEMATTE, Y
    LOISANCE, DY
    VERNANT, P
    GALEY, JJ
    EUROPEAN HEART JOURNAL, 1984, 5 : 73 - 80
  • [49] CLINICOMORPHOLOGIC CORRELATIONS FOLLOWING LONG-TERM IMPLANTATION OF CLOTH-COVERED PROSTHETIC HEART-VALVES - IMPLICATIONS FOR DEVICE DEVELOPMENT
    SCHOEN, FJ
    GOODENOUGH, SH
    IONESCU, MI
    BRAUNWALD, NS
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1983, 29 : 556 - 562
  • [50] A general model to study the dynamics of prosthetic heart valves
    Rawhouser, MA
    Gardner, JF
    Weiss, WJ
    Snyder, AJ
    Reibson, JD
    Rosenberg, G
    PROCEEDINGS OF THE IEEE 24TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 1998, : 115 - 117