Endovascular Stent-graft Management of Aortic Intramural Hematomas

被引:31
|
作者
Monnin-Bares, Valerie [1 ]
Thony, Frederic [1 ]
Rodiere, Mathieu [1 ]
Bach, Vincent [2 ]
Hacini, Rachid [2 ]
Blin, Dominique [2 ]
Ferretti, Gilbert [1 ]
机构
[1] Univ Grenoble 1, Ctr Hosp Univ A Michallon, Dept Radiol, F-38043 Grenoble, France
[2] Univ Grenoble 1, Ctr Hosp Univ A Michallon, Dept Thorac & Cardiovasc Surg, F-38043 Grenoble, France
关键词
DESCENDING THORACIC AORTA; PENETRATING ATHEROSCLEROTIC ULCERS; DIFFERENT CLINICAL-FEATURES; COMPUTED-TOMOGRAPHY; PREDICTIVE FACTORS; NATURAL-HISTORY; FOLLOW-UP; REPAIR; DISSECTION; COMPLICATIONS;
D O I
10.1016/j.jvir.2009.02.013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To report initial experience with endovascular stent-grafting in aortic intramural hematoma (IMH) MATERIALS AND METHODS: From 2000 to 2006, 15 patients (mean age, 67 years; range, 54-83 y) underwent endovascular treatment of aortic IMH. Thirteen patients were admitted for acute aortic syndrome and two for traumatic aortic injury. An endovascular procedure was performed as primary treatment for four patients (type A IMH, n = 3; type B IMH, n = 1) and as a second-line therapy in 11 patients because of unfavorable evolution (type A IMH, n = 1; type B IMH, n = 10). All stent-grafts were placed in the descending aorta, even for type A IMH. The mean follow-up was 21 months (range, 6-72 months). RESULTS: The primary success rate was 93%, with complete exclusion of the lesion (n = 14). Exclusion was partial for one patient with a type I endoleak (7%). The 30-day mortality rate was zero. IMH evolution was favorable in all cases, with decreased aortic wall thickening (n = 8) or complete regression (n = 7). Complications associated with endovascular repair were mainly related to aneurysm formation (20%). The late death rate was 7%. CONCLUSIONS: Endovascular stent-graft treatment can be performed in the management of complicated IMH, even in some cases of type A IMH, when an intimal lesion is located in the isthmus or descending aorta with contraindications to surgery. This procedure offers low morbidity and mortality rates, representing a feasible therapeutic option especially for elderly patients with comorbidities. Further studies are necessary to confirm these preliminary results.
引用
收藏
页码:713 / 721
页数:9
相关论文
共 50 条
  • [41] Endovascular Treatment of Descending Thoracic Aortic Aneurysms with the EndoFit Stent-Graft
    N. Saratzis
    Athanasios Saratzis
    N. Melas
    G. Ginis
    A. Lioupis
    D. Lykopoulos
    J. Lazaridis
    Dimitrios Kiskinis
    CardioVascular and Interventional Radiology, 2007, 30
  • [42] Endovascular stent-graft prevents rupture of experimental aortic aneurysms in sheep
    Boudghene, FP
    Sapoval, MR
    Bonneau, M
    LeBlanche, AF
    Lavaste, F
    Michel, J
    RADIOLOGY, 1996, 201 : 1356 - 1356
  • [43] A standardized aortic aneurysm model for the assessment of endovascular stent-graft technology
    Macierewicz, J. A.
    Albertini, J-N
    Hinchliffe, R. J.
    VASCULAR, 2011, 19 (02) : 82 - 88
  • [44] Thoracoabdominal aortic aneurysm: a totally endovascular approach with a branched stent-graft
    Ferreira, Marcelo
    Lanziotti, Luiz
    Cunha, Rodrigo
    d'Utra, Guilherme
    ANNALS OF CARDIOTHORACIC SURGERY, 2012, 1 (03) : 406 - 408
  • [45] Aortoduodenal fistula after endovascular stent-graft of an abdominal aortic aneurysm
    d'Othée, BJ
    Soula, P
    Otal, P
    Cahill, M
    Joffre, F
    Cérène, A
    Rousseau, H
    JOURNAL OF VASCULAR SURGERY, 2000, 31 (01) : 190 - 195
  • [46] Results of Endovascular Abdominal Aortic Aneurysm Repair with the Zenith stent-graft
    Bos, W. T. G. J.
    Tielliu, I. F. J.
    Zeebregts, C. J.
    Prins, T. R.
    van den Dungen, J. J. A. M.
    Verhoeven, E. L. G.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2008, 36 (06) : 653 - 660
  • [47] Endovascular treatment of descending thoracic aortic aneurysms with the EndoFit stent-graft
    Saratzis, N.
    Saratzis, Athanasios
    Melas, N.
    Ginis, G.
    Lioupis, A.
    Lykopoulos, D.
    Lazaridis, J.
    Kiskinis, Dimitrios
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 30 (02) : 177 - 181
  • [48] Development of a branched stent-graft for endovascular repair of aortic arch aneurysms
    Chuter, TAM
    Buck, DG
    Schneider, DB
    Reilly, LM
    Messina, LM
    JOURNAL OF ENDOVASCULAR THERAPY, 2003, 10 (05) : 940 - 945
  • [49] Endovascular Repair of Ascending Aortic Rupture: Effectiveness of a Fenestrated Stent-Graft
    Uchida, Keiji
    Imoto, Kiyotaka
    Yanagi, Hiromasa
    Machida, Daisuke
    Okiyama, Makoto
    Yasuda, Shota
    Sugiura, Tadahisa
    Kawaguchi, Satoshi
    Yokoi, Yoshihiko
    Shigematsu, Hiroshi
    Masuda, Munetaka
    JOURNAL OF ENDOVASCULAR THERAPY, 2010, 17 (03) : 395 - 398
  • [50] Type A dissection following endovascular thoracic aortic stent-graft repair
    Neuhauser, B
    Czermak, BV
    Fish, J
    Perkmann, R
    Jaschke, W
    Chemelli, A
    Fraedrich, G
    JOURNAL OF ENDOVASCULAR THERAPY, 2005, 12 (01) : 74 - 81