Algorithm automation for nuclear power plant Loose Parts Monitoring System

被引:4
|
作者
Chang, YW [1 ]
Jung, JC [1 ]
Seong, PH [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Nucl & Quantum Engn, Taejon 305701, South Korea
关键词
D O I
10.1016/j.nucengdes.2003.02.001
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Loose Parts Monitoring signals in the control room of the nuclear power plant come in through multiple channels and are presented as graphs on the display devices. It involves a lengthy and complicated process to determine the size, mass, speed, and impact location of the loose part when the signals are collected and processed. In this work, a simple and efficient model for determining the impact location of the loose part using the Least-Sum-of-Square-Errors (LSSEs) method combined with iteration has been developed based on the phase distortion of the impact signal envelopes. The signal peak point shifts to the right on the time axis when the sensor is located farther away from the impact location. This method provides a good estimation of the impact location and can be used as an alternative to existing calculations based on other attributes of the impacting signal. To automate the backend portion of the LPMS algorithm, interpolation was used for compensating the impact attenuation effect and log-log regression was also employed to determine the impacting part size and impact velocity, and the result turned out to be well in line with the manual calculations. The automated algorithm will improve the efficiency of the LPMS software. (C) 2003 Published by Elsevier B.V.
引用
收藏
页码:99 / 107
页数:9
相关论文
共 50 条
  • [21] NUCLEAR-POWER-PLANT AUTOMATION ISSUES
    WHITE, JD
    CONTROL-THEORY AND ADVANCED TECHNOLOGY, 1992, 8 (03): : 389 - 403
  • [22] KUES '95 - The modern diagnostic system for loose parts monitoring
    Bechtold, B
    Kunze, U
    PROGRESS IN NUCLEAR ENERGY, 1999, 34 (03) : 221 - 230
  • [23] Experience with identification of loose parts by acoustic monitoring of primary system
    Olma, BJ
    PROGRESS IN NUCLEAR ENERGY, 2003, 43 (1-4) : 225 - 232
  • [24] Neuro-expert monitoring system for nuclear power plant
    Nabeshima, K
    Suzudo, T
    Ohno, T
    Kudo, K
    KNOWLEDGE-BASED INTELLIGENT INFORMATION ENGINEERING SYSTEMS & ALLIED TECHNOLOGIES, PTS 1 AND 2, 2001, 69 : 1506 - 1510
  • [25] System Monitoring Program Development Process in the Nuclear Power Plant
    朱桂霞
    鲍旭东
    康澄杰
    刘伟
    秦凤
    卢冰
    JournalofDonghuaUniversity(EnglishEdition), 2018, 35 (04) : 348 - 352
  • [26] Research on Distributed Monitoring and Prediction System for Nuclear Power Plant
    Sun Y.
    Peng M.-J.
    Yang M.
    Green Energy and Technology, 2010, 44 : 310 - 314
  • [27] RESEARCH ON FATIGUE MONITORING SYSTEM DEVELOPMENT FOR NUCLEAR POWER PLANT
    Zhao Chuanli
    Chen Yinqiang
    Xu Feng
    Ji Yuanyuan
    Wang Jiangguo
    PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 1, 2017,
  • [28] RESEARCH ON FATIGUE MONITORING SYSTEM DEVELOPMENT FOR NUCLEAR POWER PLANT
    Zhao Chuanli
    Chen Yinqiang
    Xu Feng
    Ji Yuanyuan
    Wang Jiangguo
    PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 1, 2017,
  • [29] NUCLEAR-POWER PLANT RADIATION MONITORING-SYSTEM
    MCARTHUR, WC
    KNIAZEWYCZ, BG
    HEALTH PHYSICS, 1975, 29 (03): : 427 - 428
  • [30] Survey of power plant and substation automation and automation of power system dispatching
    Wang, Qiang
    Han, Yingduo
    Dianli Xitong Zidonghue/Automation of Electric Power Systems, 2000, 24 (05): : 68 - 69