Direct and efficient liquid chromatographic-tandem mass spectrometric method for opiates in urine drug testing - importance of 6-acetylmorphine and reduction of analytes

被引:17
|
作者
Andersson, Maria [1 ,2 ]
Stephanson, Nikolai [1 ,2 ]
Ohman, Inger [2 ,3 ]
Terzuoli, Tommy [1 ,2 ]
Lindh, Jonatan D. [1 ,2 ]
Beck, Olof [1 ,2 ]
机构
[1] Karolinska Inst, Div Clin Pharmacol, Stockholm, Sweden
[2] Univ Hosp, Stockholm, Sweden
[3] Karolinska Inst, Ctr Pharmacoepidemiol, Stockholm, Sweden
关键词
interpretation; opiates; 6-acetylmorphine; urine; LC-MS/MS; LC-MS/MS METHOD; MORPHINE; CODEINE; ABUSE; METABOLITES; HEROIN; PLASMA; PHARMACOKINETICS; BENZODIAZEPINES; QUANTIFICATION;
D O I
10.1002/dta.1486
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Opiates comprise a class of abused drugs that is of primary interest in clinical and forensic urine drug testing. Determination of heroin, codeine, or a multi-drug ingestion is complicated since both heroin and codeine can lead to urinary excretion of free and conjugated morphine. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) offers advantage over gas chromatography-mass spectrometry by simplifying sample preparation but increases the number of analytes. A method based on direct injection of five-fold diluted urine for confirmation of morphine, morphine-3-glucuronide, morphine-6-glucuronide, codeine, codeine-6-glucuronide and 6-acetylmorphine was validated using LC-MS/MS in positive electrospray mode monitoring two transitions using selected reaction monitoring. The method was applied for the analysis of 3155 unknown urine samples which were positive for opiates in immunochemical screening. A linear response was observed for all compounds in the calibration curves covering more than three orders of magnitude. Cut off was set to 2 ng/ml for 6-acetylmorphine and 150 ng/ml for the other analytes. 6-Acetylmorphine was found to be effective (sensitivity 82%) in detecting samples as heroin intake. Morphine-3-glucuronide and codeine-6-glucuronide was the predominant components of total morphine and codeine, 84% and 93%, respectively. The authors have validated a robust LC-MS/MS method for rapid qualitative and quantitative analysis of opiates in urine. 6-Acetylmorphine has been demonstrated as a sensitive and important parameter for a heroin intake. A possible interpretation strategy to conclude the source of detected analytes was proposed. The method might be further developed by reducing the number of analytes to morphine-3-glucuronide, codeine-6-glucuronide and 6-acetylmorphine without compromising test performance. Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:317 / 324
页数:8
相关论文
共 50 条
  • [31] Development and validation of a sensitive liquid chromatographic-tandem mass spectrometric method for the determination of cromolyn sodium in human plasma
    Lin, ZPJ
    Abbas, R
    Rusch, LM
    Shum, L
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 788 (01): : 159 - 166
  • [32] Specific, sensitive and accurate liquid chromatographic-tandem mass spectrometric method for the measurement of ribavirin in rat and monkey plasma
    Lin, CC
    Yeh, LT
    Lau, JY
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 779 (02): : 241 - 248
  • [33] Development and validation of a liquid chromatographic-tandem mass spectrometric assay for the quantification of the direct acting antivirals glecaprevir and pibrentasvir in plasma
    Garza, Kyana Y.
    Pandey, Aashish
    Marzinke, Mark A.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2023, 235
  • [34] Highly sensitive gas chromatographic-tandem mass spectrometric method for the determination of morphine and codeine in serum and urine in the femtomolar range
    Hofmann, U
    Seefried, S
    Schweizer, E
    Ebner, T
    Mikus, G
    Eichelbaum, M
    JOURNAL OF CHROMATOGRAPHY B, 1999, 727 (1-2): : 81 - 88
  • [35] A High-Performance Liquid Chromatographic-Tandem Mass Spectrometric Method for the Determination of Ethyl Glucuronide and Ethyl Sulfate in Urine Validated According to Forensic Guidelines
    Albermann, M. E.
    Musshoff, F.
    Madea, B.
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2012, 50 (01) : 51 - 56
  • [36] Development of new efficient method for isolation of phenolics from sea algae prior to their rapid resolution liquid chromatographic-tandem mass spectrometric determination
    Klejdus, Borivoj
    Plaza, Merichel
    Snoblova, Marie
    Lojkova, Lea
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 135 : 87 - 96
  • [37] Ultrahigh-Performance Liquid Chromatographic-Tandem Mass Spectrometric Multimycotoxin Method for Quantitating 26 Mycotoxins in Maize Silage
    Van Pamel, Els
    Verbeken, Annemieke
    Vlaemynck, Geertrui
    De Boever, Johan
    Daeseleire, Els
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2011, 59 (18) : 9747 - 9755
  • [38] Liquid chromatographic-tandem mass spectrometric method for the determination of the neuraminidase inhibitor zanamivir (GG167) in human serum
    Allen, GD
    Brookes, ST
    Barrow, A
    Dunn, JA
    Grosse, CM
    JOURNAL OF CHROMATOGRAPHY B, 1999, 732 (02): : 383 - 393
  • [39] Quantification of rifampicin in human plasma and cerebrospinal fluid by a highly sensitive and rapid liquid chromatographic-tandem mass spectrometric method
    Srivastava, Abhishek
    Waterhouse, David
    Ardrey, Alison
    Ward, Stephen A.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 70 : 523 - 528
  • [40] Quantitative analysis of hydrocortisone in human urine using a high-performance liquid chromatographic-tandem mass spectrometric-atmospheric-pressure chemical ionization method
    Nassar, AEF
    Varshney, N
    Getek, T
    Cheng, L
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2001, 39 (02) : 59 - 64